109
5.13.
Other engine maintenance
WARNING: To prevent injury, do not perform maintenance while the
engine is running. If maintenance must be performed with the engine
running, operate with at least two people and do the following.
One person must be in the operator's seat at all times and be ready to shut down
the engine. All personnel must keep communicating with each other.
Take special care when operating close to fans, fan belts or other rotating objects,
as there is a risk of being caught in the parts.
Do not drop or insert tools or other objects into the fan or fan belt.
WARNING: If the machine is too noisy, it can cause temporary or
permanent hearing problems. Wear ear muffs or ear plugs while
working when performing engine maintenance and being exposed to
noise for extended periods of time.
Check the fan belt tensioning
The first check is performed after 50 hours of
operation. Check every 100 hours thereafter.
To ensure proper generator operation and belt
life, the fan belt must be properly tensioned.
For a properly tensioned belt, apply 10 kg
perpendicular to the belt between the fan pulley
and the generator pulley, and the belt will sink
by about 10 mm.
If the belt is found to be damaged, it needs to be
replaced.
For the maintenance intervals and details of other engine components, refer
to the Diesel Engine Instruction Manual supplied with the machine.