Air F ilter R egulators Y T -200, Y T -205
- 6 -
Part Name
Qty
Stem
1 (ea)
Diaphragm Assembly
1 (ea)
Filter
1 (ea)
O-Ring
2 (ea)
Maintenance
Please refer to below table (repair kit) and parts' name. Before replacing any parts,
please make sure to follow field's safety procedure and the manual to avoid any
accidents and damages to the product.
Repair kit
When using Repair Kit, all of the parts must be replaced at the same time. Partial part
replacement may result in shortening product's life cycle.
▶
Draining condensed water
①
When draining out condensed water, supply air pressure must be shut down
completely or adjust the pressure level below 1kgf/cm
2.
The operator can be
seriously hurt when draining out at high pressure.
②
Slowly open drain plug to drain condensed water.
③
After draining out completely, close the drain plug.
▶
Replacing filter case and parts
①
Shut off supply air pressure.
②
Release lock nut on adjust bolt, rotate adjust bolt counter-clockwise to lower
setting pressure.
③
Open drain plug on filter case to drain condensed water and close.
④
Unscrew bolts on filter case in diagonal order.
⑤
Replace filter, o-ring, and stem.
⑥
Screw bolts on filter case in diagonal order.
⑦
Unscrew 6 bolts on spring case in diagonal order.
⑧
Replace diaphragm assembly.
⑨
Screw bolts on spring case in diagonal order. Make sure not to damage
diaphragm when screwing.
⑩
After part replacement, set air pressure to desired level.