background image

Air  F ilter  R egulators                                                                                Y T -200,  Y T -205

-  5  -

Instruction

(1) Before supplying air pressure into YT-200, turn adjust bolt counter-clockwise, so      

the ring is not pushed.  

(2) Install pressure gauge on the secondary pressure output port.  The pressure          

 gauge indicates primary pressure that is being output.  

(3) Air pressure is supplied through primary pressure input port after output port is        

being blocked by using ball-valve or other fitting tools.  

(4) When the secondary pressure reaches at set level, fasten the adjust bolt 

      

    completely.  

Output and Flow (LPM)

Pressure

Flow (LPM)

     

Содержание YT-200 Series

Страница 1: ...Air Filter Regulators YT 200 YT 205 USER S MANUAL YTC V 1 02...

Страница 2: ...ion of pressure input z Aluminum body increases versatility of the product in different environments z 5 micron filter sorts minuteness particles in the air z Relief function is available which discha...

Страница 3: ...r Connection PT NPT 1 4 NPT1 4 Gauge Connection PT NPT 1 8 NPT1 8 Ambient Temperature 20 70 Standard 20 120 High Temp 40 120 Low Temp Min Filtering Size 5 micron Material Aluminum Stainless Steel 316...

Страница 4: ...ockwise which will push diaphragm then disconnects from stem and disc The set pressure level stays by transferring pressure to lower diaphragm which results to balance adjust spring In case of higher...

Страница 5: ...ce release drain bolt on timely basis to extract any water inside z Filter must be replaced on timely basis Filter usage depends on the environment field z After pressure is set please make sure adjus...