background image

Air  F ilter  R egulators                                                                                Y T -200,  Y T -205

-  2  -

Category

YT-200

YT-205

A

B

C

Max Supply Pressure

15kgf/

㎠ 

(231psi)

Max Output Pressure

4.2kgf/

8.4kgf/

2.1kgf/

Air Connection

PT(NPT) 1/4

NPT1/4

Gauge Connection

PT(NPT) 1/8

NPT1/8

Ambient Temperature

-20~70

(Standard), 

-20~120

(High Temp.), -40~120

(Low Temp.)

Min Filtering Size

5 micron

Material

Aluminum

Stainless Steel 316

Weight

0.6kg

1.4kg

Specification

Parts and Assembly

Please be knowledgeable of product's major parts and assembly steps for future 

maintenance. 

Содержание YT-200 Series

Страница 1: ...Air Filter Regulators YT 200 YT 205 USER S MANUAL YTC V 1 02...

Страница 2: ...ion of pressure input z Aluminum body increases versatility of the product in different environments z 5 micron filter sorts minuteness particles in the air z Relief function is available which discha...

Страница 3: ...r Connection PT NPT 1 4 NPT1 4 Gauge Connection PT NPT 1 8 NPT1 8 Ambient Temperature 20 70 Standard 20 120 High Temp 40 120 Low Temp Min Filtering Size 5 micron Material Aluminum Stainless Steel 316...

Страница 4: ...ockwise which will push diaphragm then disconnects from stem and disc The set pressure level stays by transferring pressure to lower diaphragm which results to balance adjust spring In case of higher...

Страница 5: ...ce release drain bolt on timely basis to extract any water inside z Filter must be replaced on timely basis Filter usage depends on the environment field z After pressure is set please make sure adjus...

Страница 6: ...gauge on the secondary pressure output port The pressure gauge indicates primary pressure that is being output 3 Air pressure is supplied through primary pressure input port after output port is being...

Страница 7: ...or adjust the pressure level below 1kgf cm2 The operator can be seriously hurt when draining out at high pressure Slowly open drain plug to drain condensed water After draining out completely close th...

Страница 8: ...ligence misuse faulty installation lack of reasonable care repair or service in any way that is not contemplated in the documentation for the product or if the model or serial number has been altered...

Отзывы: