9
Electrical Guidelines
Individually fuse each light with the appropriate type
of fuse. Consult the table on the right to select the
correct fuse rating for your lights.
Two blade-type fuses are supplied with each light.
These fuses are compatible with the YPHOS Hubs
(fused Junction Boxes) and any blade fuse holder.
Fuse recommendations
White
Blue
White + Blue
RGBW
Version
24V
12V
4 A
4 A
4 A
4 A
8 A
8 A
8 A
8 A
Do not connect the lights to any voltage other than the rated 12V-24V DC. Isolate power source
prior to installation.
Color coding of Model 03 wires is as follows:
Red:
12V or 24V DC
Black:
Ground
Blue: (present in some models):
Y:link
Always use appropriate type and size of cables. If you extend the factory built-in cables, always
make waterproof connections and make sure that the correct cable gauge is used following the
ABYC recommendations for DC connections.
Individually fuse each light - consult the table below.
Secure the cables and make sure that the wires are not under stress.
If lights are not synchronized, turn off for 10 seconds and on again. The Y:link enabled lights offer
absolute synchronisation between fixtures and can also be addressed.