25
Image Interval
This is the time delay between camera snapshots sent in an MMS. The default is 0.5 seconds.
Command:
#103#ImageInterval#
Example:
#103#10#
Response:
Image capture interval has been set to 10
Image Interval may take values 3 to 10:
ImageInterval
Value in seconds
Value in Milliseconds
3
0.3
300
4
0.4
400
5
0.5
500
6
0.6
600
7
0.7
700
8
0.8
800
9
0.9
900
10
1.0
1000
Image Brightness
YOYOCam supports five brightness levels to adjust the camera to the ambient light level. Brightness
level 1 is darkest and 5 is lightest. Default is 4.
Command:
#34#BrightnessLevel#
Example:
#34#3#
Response:
Brightness has been set to 3
Note: Check your image brightness setting in each different condition (e.g. daylight, night) to make
sure that the image is captured ok.
Image Contrast
YOYOCam supports five contrast levels to adjust the camera to the ambient conditions. Contrast
level 1 is softest and 5 is most contrasty. Default is 4.
Command:
#38#ContrastLevel#
Example:
#38#3#
Response:
Image contrast has been set to 3
Note:
Check your image contrast setting in each different condition (e.g. daylight, night) to make sure
that the image is captured ok.
Wireless Sensors
You can add up to 15 external wireless sensors which operate on the 433MHz standard. When
YOYOCam is armed and a sensor is triggered, YOYOCam will emit a warning bleep and raise an