4.3.4 COUPLING REPLACEMENT
1) TOOL AND MATERIAL
TOOL
MATERIAL
1. SPANNER(13mm)
1. COUPLING
2) WROK METHOD
NO
PHOTO
WORK METHOD
1
-. When replacing broken coupling, un-
fasten 2 hexagon bolts with spanner
(13mm).
-. Take the broken coupling away from
Light.
-. Take coupling away from plate as well.
-. Assemble a new coupling into plate.
-. Assemble light into coupling.
-. Fix the light with spanner.
NOTE : When fixing the light, watch out not
to be bent out of main beam direction.
5.운송 및 보관
5.1 STORAGE
1) All Lights are supplied by each packing box and each box has name plate and
indicated box content at outside of box.
2) All light must be stored at dry condition without dust in the room.
5.2 2 Storage Atmosphere condition
1) Place : Dry and No dust place
2) Temperature : - 55~ +70 °C
3) Humidity : below than 90%