clear the maximum and minimum record.

When viewing the memory record, press “MEMORY” button (B3) again to check 

the  corresponded  time  and  date  for  memory  maximum  and  minimum 
temperature  &  humidity  record.  The  memory  record  value  and  corresponded 
time and date flash. Press “MEMORY” button select to view:

Time  &  date  for  minimum  temperature  memory  record,  Time  and  date  for 

maximum temperature  memory  record,  Time  &  date  for  minimum  humidity 

memory record, Time and date for maximum humidity memory record.

(3) Celsius / Fahrenheit

Press “°C /°F” button (B5) to select Indoor/Outdoor Temperature in Celsius mode 
or Fahrenheit mode. 

If  the  temperature  is  out  of  the  measurable  range,  LL.L  (beyond  the  minimum 

temperature) or HH.H (beyond the maximum temperature) will be shown on the 

LCD.

(4) Humidity

The  humidity  measurable  range  is  20%  ~  99%.  If  the  current humidity 

measurement is lower than 20%, the LCD would display

.

For past 24 hours or memory maximum or minimum temperature and humidity 

record. If the record is lower than 20%, the LCD would display 

(5) Outdoor Temperature Alert Function

Press  “ALERT”  button  (B7)  to select  to  activate  or  deactivate  outdoor 
temperature alert function. 

press ALERT button select to:

Active  outdoor  upper  temperature alert,  the  icon  “

” besides  outdoor 

temperature digit would display.

Active  outdoor  upper&  lower  temperature alert,  the  icon  “

” besides 

outdoor temperature digit would display.

Active  outdoor  lower  temperature alert,  the  icon  “

” besides  outdoor 

temperature digit would display.

   Deactivate outdoor temperature alert, alert icon disappear. 

Hold  “ALERT” button  (B7)  for  3  seconds  to  enter outdoor  temperature alert 

setting.  Icon  “

” or  “

” beside  Temperature’s  digits  flash. Press  “+” or  “-

Содержание YC9330

Страница 1: ...al 1 Features 1 1 Weather Forecast Two Weather Icon Sunny Slightly Cloudy Cloudy Rainy and Snow animation 1 2 Time Radio Controlled Time Perpetual Calendar Up to Year 2099 Daily Alarm Function 1 3 Humidity Indoor Outdoor measurable range 20 99 Outdoor Humidity Record from Start Up Reset and the corresponded time 24 Hours Min Max Display for Outdoor Humidity 1 4 Temperature Indoor measurable range ...

Страница 2: ...2 2 Main Unit Appearance 2 1 Part A LCD A1 Outdoor Temperature A2 Temperature Memory A3 Outdoor Humidity A4 Humidity Memory A5 Weather Forecast A6 Comfort Indicator ...

Страница 3: ... LED D2 Outdoor Temperature display D3 Outdoor Humidity display D4 Battery Compartment D5 Wall Mount Hole D6 RESET button D7 C F button D8 Stand 4 Getting Started 4 1 Main Unit Open main unit battery compartment cover C2 Insert 3 x AAA batteries observing polarity and marks Replace main unit battery compartment cover C2 Use a pin to press the RESET B1 button on the rear of the main unit the main u...

Страница 4: ...nds weather icon flash A5 on the LCD Enter the current weather by pressing B5 or B4 button Press WEATHER B8 button to confirm the setting The weather forecast may not be accurate if the current weather entered is not correct There are two weather icons the left one indicate current weather condition the right one forecasts the weather in terms of getting better or worse The weather station will st...

Страница 5: ... to the main unit after batteries inserted If main unit failed to receive transmission from outdoor thermo sensor in first 3 minutes after the batteries inserted display on the LCD hold SEARCH button B9 for 3 seconds to receive transmission manually RF icon flashes on the LCD 7 2 Temperature Humidity 1 Past 24 Hours Maximum Minimum Outdoor Temperature and Humidity After start up the unit automatic...

Страница 6: ...re will be shown on the LCD 4 Humidity The humidity measurable range is 20 99 If the current humidity measurement is lower than 20 the LCD would display For past 24 hours or memory maximum or minimum temperature and humidity record If the record is lower than 20 the LCD would display 5 Outdoor Temperature Alert Function Press ALERT button B7 to select to activate or deactivate outdoor temperature ...

Страница 7: ... successfully disappear Indicating signal reception failed The clock automatically scans the time signal at 2 00 a m every day to maintain accurate timing If reception fail scanning stops on LCD disappear The clock can be set to scan the time signal manually by holding buttons B4 B5 for 3 seconds Each reception takes about 5 minutes Stop scanning by holding buttons B4 B5 for 3 seconds shown on the...

Страница 8: ... indicating that thermo sensor is in low battery status The batteries should be replaced 10 Precautions Use a pin to press the reset button B1 if the Unit does not work properly Avoid placing the clock near interference sources metal frames such as computer or TV sets The clock loses its time information when the battery is removed Do not expose it to direct sunlight heavy heat cold high humidity ...

Страница 9: ...s Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local and or regional authorities to retrieve the addresses of legal dumping grounds with selective collection All electronic instruments must from now on be recycled User shall take an active part in the re use recycling and recovery of the electrical and electronic w...

Страница 10: ... a toy Keep out of the reach of children No part of this manual may be reproduced without written authorization of the manufacturer R TTE Directive 1999 5 EC Summary of the Declaration of Conformity We hereby declare that this wireless transmission device All enquires service youshiko co uk ...

Отзывы: