System Program
7
It will be no number repeat while there is call forward or user
’
s recorded
prompt for transfer
Once the Ext. number is less then 4 digits, enter # to end or wait
3sec. time out. For example: X# , XX# , XXX#.
While Ext. number is more then 4 digits, please refer to page 15
For beginning No., dial 1
For ending No., dial 2
For backup ext., dial 3
1 for ring times to answer call by line 1 [1]
2 for ring times to answer call by line 2 [1]
3 for retry times of external notification [2]
4 for retry times of pager notification [2]
5 for operator code [0]
6 for 2
nd
language code [ ]
7 for 3
rd
language code [ ], 8 for 4
th
language code [ ]
9 for retry times of internal notification [2]
0 for retry times to operator [1]
Have set X. To confirm, press # sign. Or re-enter, up to 9
To set
ring times
&
operator
code,
dial 3
To edit
ext. group
& backup
extension
dial 1
Please enter group no. from
01 up to 32
Number is XXXX. To confirm, press # sign, or
re-enter, up to 4 digits, 0000 means to delete
Have set XX (sec.). To confirm, press # sign, or
re-enter up to 99, 00 means to delete.
To revise
waiting
time of
each
function
dial 2
1 for waiting time to dial [3]
2 for OP ring duration during working hrs [20]
3 for OP ring duration during closing hrs [20]
4 for ext. ring duration during working hrs [20]
5 for ext. ring duration during closing hrs [20]
6 for maximum recording time of a message [60]
8 for internal notification period [30](min.)
To set
user’s
function
&
mainten-a
nce,
dial 4
SYS_1
SYS_2
SYS_3
SYS_4
Have set “yes”(no). To confirm, press # sign. Or re-enter, 1 for yes, 2 for no
1 for number repeat [1]
3 for raising greeting words volume [2]
4 for no dial re-greeting then cut off [2]
5 for dial tone detection [1]
6 for larger tolerance in tone detection [2]
7 for Port (locked up) Auto-detection [2]
8 for tone in frequency band [1]
9 for message notification at wakeup [2]
Ring duration: 00 means Un-supervisory transfer
The recording time step by 20 sec, 00 means 270 sec.
The exact operator number must be set through ADM_4
Operator code
/
language
code =* , regard as null
SYS_N
Group No. must be successive
Ring times of line3,5,7 same as line-1, and line-4,6,8 same as line-2
Press
#
to return to previous menu or to end data entry.
You could wait time out to previous menu or re-enter again while data entry incorrect.
Frequency band: 300-640Hz
8
Special code:
*- enter **
#- enter *1
A - enter *2
B - enter *3
C - enter *4
Timing is X.XX. To confirm, press # sign.
or re-enter; in 3 digits; not exceed 7.90 sec.
(@=33ms) , 000 means to delete
Dialing way is X. To confirm, press # sign. Or re-enter again
1 for touch tone (output: 0.1sec, pause: 0.1sec)
2 for long touch tone (output: 0.3sec, pause: 0.3sec)
3 for dial pulse
To set
operating
way for
each
function
of PBX ,
dial 5
1 for dialing way [1]
2 for release after answer [5]
3 for release w/o waiting [5]
4 for retrieving call once error tone [1]
5 for retrieving call once on-busy [1]
6 for retrieving call once no answer [1]
7 for message lamp on [8]
8 for message lamp off [8]
To set
remote
control
password
&
function
code
for PBX,
dial 6
No. is XXXX. To confirm, press # sign, or re-enter, up to 4 digits, 0000 means to delete
To set
each
timing for
PBX,
dial 7
First cycle_ON, dial 1
First cycle_OFF, dial 2
Second cycle_ON, dial 3
Second cycle_OFF, dial 4
To exit,
press
#
sign
1 for call-transferring code [ ]
2 for call-retrieving code [ ]
3 for no-answer identified code [ ]
4 for busy identified code [ ]
5 for trunk access code [ ]
6 for code of message lamp on [ ]
7 for code of message lamp off [ ]
8 for program password [0#0#]
9 for administrator password [ ]
0 for area code [ ]
* for suffix code [ ]
1 for hook flash [Auto-configuration]
2 for internal ring cycle [ ]
3 for delay before tone detect [0.03]
4 for error tone cycle [Auto-config. ]
5 for busy tone cycle [Auto-config.]
6 for ring tone cycle [Auto-config.]
7 to read tone cycle of call processing
SYS_5
Operating way is X. To confirm, press # sign.
Or re-enter again
1 for "hook flash"
2 for "hook flash"
+
"function code"
3 for "hook flash" twice
4 for "hook flash" and then "on & off hook"
5 for "on & off hook"
6 for "on & off hook" plus "function code"
7 for "on & off hook" and then "hook flash"
8 for "function code" + "extension No." + suffix code
9 for "extension No." + "function code" + suffix code
SYS_6
SYS_7
To go into
administr-
ator
program,
dial 0
The tone cycles will be Auto-configured, but you
also can enter data into SYS_7_4/5/6_[ ] directly,
while the data has been recognized.
To set tone cycle =000 will make tone detection in
Smart mode
There is a tone after SYS_7_6 entry while system is still in Auto-configuration
Recovery to Auto-configuration: to set SYS_7_8_1_[000]
Data of messagelamp on/off would be 2、 8、 9