background image

YO Power

User guide

v4.0

page 16/28

Device configuration

Configurable parameters

A few parameters must be set before sending data to the gateway. The default firmware is configured
in OTAA mode with predefined

deveui

,

appkey (

OTAA

)

and

appskey

,

nwkskey (

ABP

)

.

Configuration of the device is stored in a JSON file divided into the following sections:

-

info

(generic, read only): information about the device,

-

lorawan

(generic): configuration data for LoRaWAN connection,

-

ble

(generic): bluetooth settings,

-

device

(dynamic): individual configuration for a specific device (this section’s structure differs

for each device),

Sample configuration file for the YO Power device

.

{

"info": {

"devmodel": "LNPW",
"fwver": "3.5.0",
"loraradio": "SX1261",
"lorawanver": "1.0.2",
"loraregion": "EU868",
"blemacaddr": "0123456789ab"

},
"lorawan": {

"subband": 1,
"nwktype": "public",
"acttype": "otaa",
"otaa": {

"deveui": "0123456789abcdef",
"appeui": "fedcba9876543210",
"appkey": "000102030405060708090a0b0c0d0e0f",
"trials": 3

},
"abp": {

"devaddr": "01234567",
"nwkskey": "0123456789abcdef0123456789abcdef",
"appskey": "000102030405060708090a0b0c0d0e0f"

}

},
"ble": {

"power": 0,
"interval": 1600

},
"device": {

"measinterval": 300,
"measthreshold": 10,
"ch1cttype": "50mA-100A",
"ch2cttype": "50mA-100A",
"ch3cttype": "50mA-100A",
"ch4cttype": "50mA-100A",
"ch5cttype": "50mA-100A",
"ch6cttype": "50mA-100A"

}

}

www.yo

sensi

.

io

Содержание YO Power

Страница 1: ...YO Power User guide v4 0...

Страница 2: ...ns of the device Installation instruction upgraded device configuration and operation of the device updated payloads description added compliance statement 31 07 2023 4 0 Added CT clamps up to 1000 A...

Страница 3: ...Package contents 9 Safety precautions 9 Installation guide 10 Operation 15 IoT system components 15 Device configuration 16 Configurable parameters 16 Parameters description 18 Configuration node with...

Страница 4: ...ingle phase devices etc It is possible to install current clamps without knowing the direction through which the current flows Wireless communication eliminates the need for additional wiring or conve...

Страница 5: ...STATUES INTERPRETATION BEHAVIOUR COLOUR DEVICE STATUS Single flash Green General device is working correctly power and memory Single flash Red General device is working incorrectly power and memory L...

Страница 6: ...vice PHYSICAL SPECIFICATION Dimensions Height 90 mm Width 71 2 4 pole mm Depth 58 mm Colour Light grey Mounting method 35 mm DIN rail Vertical can be screwed to the wall Enclosure material Polycarbona...

Страница 7: ...T Model 50mA 200 A 3 CT Model 50mA 400 A 3 CT Model 50mA 600 A 3 CT Model 50mA 800 A 3 CT Model 50mA 1000 A 3 Power consumption 0 230 V Not given in datasheet Current YO Power offers automatically swi...

Страница 8: ...easured by YO Power and attached to it CT clamps is a value calculated for each hour for 230 V and current flowing on each channel It helps monitor customers how much power is consumed by the devices...

Страница 9: ...cing battery connecting input or doing some other operations near inside electronics Be careful while handling the device dropping it may cause damage that will affect the sensors and other electronic...

Страница 10: ...YO Power User guide v4 0 page 10 28 Installation guide 1 Mount the device on a 35 mm DIN rail Figure 6 Device mounting instructions www yosensi io...

Страница 11: ...e v4 0 page 11 28 2 Connect the inputs to the individual channels of the device according to the polarity shown on the enclosure label Figure 7 Connect the inputs to the individual channels of the dev...

Страница 12: ...page 12 28 3 Fasten the current clamps around the wires in which the current is to be measured a clamp should be placed around one wire Figure 8 Instruction on how to fasten the current clamps around...

Страница 13: ...O Power User guide v4 0 page 13 28 4 Screw the power supply wires to the device regardless of polarity 6 30 V DC 5 21 V AC Figure 9 Instruction on how to connect the power to the device www yosensi io...

Страница 14: ...YO Power User guide v4 0 page 14 28 Figure 10 Final look of the device www yosensi io...

Страница 15: ...ay 2 Gateway device similar to routers equipped with a LoRa concentrator that receives LoRa packets and send them to the Internet connected server 3 Server in most cases a cloud based service where da...

Страница 16: ...vidual configuration for a specific device this section s structure differs for each device Sample configuration file for the YO Power device info devmodel LNPW fwver 3 5 0 loraradio SX1261 lorawanver...

Страница 17: ...EUI Extended Unique Identifier 8 B HEX predefined R W appeui Application EUI 8 B HEX predefined R W appkey Application Key 16 B HEX predefined R W trials Join request trials 1 9 3 R W lorawan abp deva...

Страница 18: ...ific to the particular MCU and are unique for each device they can be changed if needed interval determines the interval of sending broadcast packets used to connect to every BLE receiver around the d...

Страница 19: ...10 3 911 7 MHz channels 40 47 6 Sub band 7 911 9 913 3 MHz channels 48 55 7 Sub band 8 915 5 914 9 MHz channels 56 63 8 AU915 Sub band 1 915 2 916 6 MHz channels 0 7 1 2 R W Sub band 2 916 8 918 2 MHz...

Страница 20: ...ent buttons Configure here you can change and upload the device parameters Update firmware here you can update the firmware to version 3 4 0 and newer Recover device this section restores the firmware...

Страница 21: ...si io The application is a representation of each system and together with the node definitions is created by customers The basic integration of a node into the Yosensi Management Platform is describe...

Страница 22: ...section appkey All device identifiers are provided by Yosensi Support when you order the nodes Select a model that is compatible with your device this choice affects the number of charts and data sour...

Страница 23: ...de configuration Click on the link in the Node Name column Go to the KEYS tab and switch LoRa Type from OTAA to ABP and fill in the blank spaces then press update The identifiers Device Address devadd...

Страница 24: ...plication click the bottom right button Fill in the Name and Description fields and select the Application Profile which is the region definition 4 Proceed to the application by clicking its name on t...

Страница 25: ...4a 2e 2a 11 01 02 ad 2e 2a Second frame 02 03 01 16 2e 00 11 03 02 a5 2e 00 11 04 02 70 2e 01 11 05 02 a9 2e 01 11 06 02 a1 2e 09 11 01 00 01 2e 09 11 02 00 00 2e 09 The payload starts building from t...

Страница 26: ...s 0 addr_len 1 meas_len 2 addr 5 val 781 7 81 A Fifth measurement CH6 current 0x2E 0x00 0x11 0x06 0x03 0x4A type 11 prec 2 md s 0 addr_len 1 meas_len 2 addr 6 val 845 8 45 A Sixth measurement CH1 curr...

Страница 27: ...YO Power User guide v4 0 page 27 28 Compliance statements www yosensi io...

Страница 28: ...YO Power User guide v4 0 page 28 28 www yosensi io...

Отзывы: