page 14/15

Second measurement

0x2E

0x00

0x11

0x02

0x01

0x90

type = 11,

prec = 2

md [s] = 0

addr_len = 1,
meas_len = 2

addr = 2

val = 400

(4,0 [mA])

Third measurement

0x2E

0x00

0x11

0x03

0x04

0x1A

type = 11,

prec = 2

md [s] = 0

addr_len = 1,
meas_len = 2

addr = 3

val = 1050

(10,5 [mA])

Fourth measurement

0x32

0x00

0x11

0x04

0x00

0x00

type = 12,

prec = 2

md [s] = 0

addr_len = 1,
meas_len = 2

addr = 4

val = 0

(0,0 [V])

Fifth measurement

0x32

0x00

0x11

0x05

0x01

0xE6

type = 12,

prec = 2

md [s] = 0

addr_len = 1,
meas_len = 2

addr = 5

val = 486

(4,86 [V])

Sixth measurement

0x32

0x00

0x11

0x06

0x00

0xF1

type = 12,

prec = 2

md [s] = 0

addr_len = 1,
meas_len = 2

addr = 6

val = 241

(2,41 [V])

REV 2.0.0

www.yo

sensi

.

io

Содержание YO Analog

Страница 1: ...YO Analog User guide v2 0...

Страница 2: ...ser guide v2 0 page 2 15 Release notes Released Version Key changes 11 06 2021 1 0 Initial release 13 12 2021 2 0 Change of power supply from 100 240 V AC 50 60 Hz to 6 30 V DC 5 21 V AC REV 2 0 0 www...

Страница 3: ...2 Product description 4 Overview 4 Applications 4 IoT system components 5 Device configuration 6 Configurable parameters 6 Quick start guide 9 Node configuration 9 YO Suite configuration 10 Payload de...

Страница 4: ...signals The device has six configurable measurement inputs each of which can be used in one of two modes voltage input 0 10 V or current input 4 20 mA Figure 1 Device top view Visible device elements...

Страница 5: ...module that gathers data forms the payload and sends it to the gateway 2 Gateway device similar to routers equipped with a LoRa concentrator that receives LoRa packets and pushes them to the Internet...

Страница 6: ...16 B HEX predefined R W addrabp ABP device address 4 B HEX predefined R W nwkskey Network Session Key 16 B HEX predefined R W appskey Application Session Key 16 B HEX predefined R W advble Interval ad...

Страница 7: ...r by more than specified by this parameter see equation below the present value and timestamp will be saved and prepared for transmission to the server see figure 4 where a current measurement b immed...

Страница 8: ...YO Analog User guide v2 0 page 8 15 Figure 4 Threshold algorithm visualisation tli measinter ts time between consecutive measurements p1 p3 measurements values th measlevel...

Страница 9: ...e sure you have your Bluetooth LE adapter turned on and working properly 3 Download and run the CLI tool in the terminal console application 4 Connect power supply pins regardless of polarity of the Y...

Страница 10: ...ple in our recommended YO Suite software NOTE The firmware update process is described in CLI tool manual page 13 Visit https yosensi io support to see all available documentation YO Suite configurati...

Страница 11: ...d press the button to add a node Select Lora in Node Type field Set the Name Description fields and fill in Node ID deveui and OTAA Key keyotaa which can be found using the CLI tool list_dev_params Se...

Страница 12: ...ABP after activation in YO Suite by changing the Node configuration Click on the link in the Node Name column Go to the KEYS tab and switch Lora Type from OTAA to ABP and fill in the Device Address ad...