3. To create an application, press the bottom right ‘+’ button. Fill in the ‘Name’ and

‘Description’ fields and ‘Select Application Profile’ which is the region definition.

Figure 6

Application creation form.

4. Proceed to the application by clicking its name on the list, and press the ‘+’ button to add a

node. Select ‘Lora’ in ‘Node Type’ field. Set the ‘Name’, ‘Description’ fields and fill in ‘Node
ID’ (

deveui

) and ‘OTAA Key’ (

keyotaa

)

which can be found using the CLI tool

(

list_dev_params

).

Select a model that is compatible with your device—it affects the

number of charts, its placement and data source (YO Analog model). You can also set the
node’s ‘Location’, if locations have been pre-defined. If you haven’t defined a suitable
location, leave this field set at <None>.

REV 2.0.0

www.yo

sensi

.

io

Содержание YO Analog

Страница 1: ...YO Analog User guide v2 0...

Страница 2: ...ser guide v2 0 page 2 15 Release notes Released Version Key changes 11 06 2021 1 0 Initial release 13 12 2021 2 0 Change of power supply from 100 240 V AC 50 60 Hz to 6 30 V DC 5 21 V AC REV 2 0 0 www...

Страница 3: ...2 Product description 4 Overview 4 Applications 4 IoT system components 5 Device configuration 6 Configurable parameters 6 Quick start guide 9 Node configuration 9 YO Suite configuration 10 Payload de...

Страница 4: ...signals The device has six configurable measurement inputs each of which can be used in one of two modes voltage input 0 10 V or current input 4 20 mA Figure 1 Device top view Visible device elements...

Страница 5: ...module that gathers data forms the payload and sends it to the gateway 2 Gateway device similar to routers equipped with a LoRa concentrator that receives LoRa packets and pushes them to the Internet...

Страница 6: ...16 B HEX predefined R W addrabp ABP device address 4 B HEX predefined R W nwkskey Network Session Key 16 B HEX predefined R W appskey Application Session Key 16 B HEX predefined R W advble Interval ad...

Страница 7: ...r by more than specified by this parameter see equation below the present value and timestamp will be saved and prepared for transmission to the server see figure 4 where a current measurement b immed...

Страница 8: ...YO Analog User guide v2 0 page 8 15 Figure 4 Threshold algorithm visualisation tli measinter ts time between consecutive measurements p1 p3 measurements values th measlevel...

Страница 9: ...e sure you have your Bluetooth LE adapter turned on and working properly 3 Download and run the CLI tool in the terminal console application 4 Connect power supply pins regardless of polarity of the Y...

Страница 10: ...ple in our recommended YO Suite software NOTE The firmware update process is described in CLI tool manual page 13 Visit https yosensi io support to see all available documentation YO Suite configurati...

Страница 11: ...d press the button to add a node Select Lora in Node Type field Set the Name Description fields and fill in Node ID deveui and OTAA Key keyotaa which can be found using the CLI tool list_dev_params Se...

Страница 12: ...ABP after activation in YO Suite by changing the Node configuration Click on the link in the Node Name column Go to the KEYS tab and switch Lora Type from OTAA to ABP and fill in the Device Address ad...

Страница 13: ...me column link and clicking CHARTS Payload description If you want to connect to your own server you need the payload decoder which can be found at https yosensi io support Example of YO Analog payloa...

Страница 14: ...d s 0 addr_len 1 meas_len 2 addr 3 val 1050 10 5 mA Fourth measurement 0x32 0x00 0x11 0x04 0x00 0x00 type 12 prec 2 md s 0 addr_len 1 meas_len 2 addr 4 val 0 0 0 V Fifth measurement 0x32 0x00 0x11 0x0...

Страница 15: ...User guide v2 0 page 15 15 Revision history Date Version Changes 11 06 2021 1 0 Initial release 13 12 2021 2 0 Change of power supply from 100 240 V AC 50 60 Hz to 6 30 V DC 5 21 V AC REV 2 0 0 www y...