background image

IMPORTANT SAFETY INSTRUCTIONS

safety-4v3.eps • Oct. 26/05

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

INSTRUCTIONS PERTAINING TO A

RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS

Read Instructions

The Owner’s Manualshould be read and understood 
before operation of your unit. Please, save these instruc-
tions for future reference.

Packaging

Keep the box and packaging materials, in case the unit 
needs to be returned for service.

Warning

When using electric products, basic precautions should 
always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage 
specified in the owners manual or as marked on the unit. This unit has a 
polarized plug. Do not use with an extension cord or receptacle unless 
the plug can be fully inserted. Precautions should be taken so that the 
grounding scheme on the unit is not defeated.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or 
table. The product may fall, causing serious personal injury and serious 
damage to the product. Use only with cart, stand, tripod, bracket, or 
table recommended by the manufacturer or sold with the product. 
Follow the manufacturer’s instructions when installing the product and 
use mounting accessories recommended by the manufacturer.

The apparatus should not be exposed to dripping or splashing water; 

no objects filled with liquids should be placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the 

external wiring connected to these terminals require installation by an 
instructed person or the use of ready made leads or cords.

Ensure that proper ventilation is provided around the appliance.
No naked flame sources, such as lighted candles, should be 

placed on the apparatus.

Power Cord

The AC supply cord should be routed so that it is unlikely that it will be 
damaged. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.

Service

The unit should be serviced only by qualified service personnel.

AVIS:

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,

N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)

 

NE CONTIENT AUCUNE PIECE

REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE

POUR L’ENTRETIENT

INSTRUCTIONS RELATIVES AU RISQUE

DE FEU, CHOC ÉLECTRIQUE, OU

BLESSURES AUX PERSONNES

Veuillez Lire le Manuel

Il contient des informations qui devraient êtres comprises 
avant l’opération de votre appareil. Conservez S.V.P. ces 
instructions pour consultations ultérieures.

Emballage

Conservez la boite au cas ou l’appareil devait être 
retourner pour réparation.

Attention:

Lors de l’utilisation de produits électrique, assurez-
vous d’adhérer à des précautions de bases incluant 
celle qui suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation 
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué sur 
l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. 
Ne pas utiliser cet appareil avec un cordon de raccordement à moins 
qu’il soit possible d’insérer complètement les trois lames. Des 
précautions doivent êtres prises afin d’eviter que le système de mise à 
la terre de l’appareil ne soit désengagé.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une 
table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir 
des dommages importants. Utiliser seulement un chariot, un support, 
un trépied ou une table recommandés par le fabricant ou vendus avec 
le produit. Suivre les instructions du fabricant pour installer l’appareil et 
utiliser les accessoires recommandés par le fabricant.

Il convient de ne pas placer sur l’appareil de sources de flammes 

nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des 

éclaboussures et qu’aucun objet rempli de liquide tel que des vases 
ne doit être placé sur l’appareil.

Assurez que lappareil est fourni de la propre ventilation.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties 

dangereuses au toucher et que les câblages extérieurs connectés à 
ces dispositifs de connection extérieure doivent être effectivés par un 
opérateur formé ou en utilisant des cordons déjà préparés.

Cordon d’Alimentation

Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS 
L’APPAREIL si le cordon d’alimentation est endommagé.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil.

Содержание XS800H

Страница 1: ...TYPE YS1027 OWNER S MANUAL MANUEL de L UTILISATEUR 800 TYPE YS1035...

Страница 2: ...ISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES A...

Страница 3: ...tailor your sound precisely and uniquely The Resonance control allows you to tweak the bass tone from tight to loose Five band active tone shaping controls Including a fine tunable Parametric Mid Exte...

Страница 4: ...INTAKE VENTS CLEAR OF OBSTRUCTIONS ATTENTION KEEP THE SIDE EXHAUST VENTS AND REAR INTAKE VENTS CLEAR OF OBSTRUCTIONS SPEAKER OUTPUTS Min 2 ohms SPEAKON Pin Configuration 1 1 Yorkville 230V 50Hz 2 5A 1...

Страница 5: ...udibly as well as visually a red LED located to the right of the control will illu minate as the compressor limits the signal The LED will also indicate the how much compression is being applied by it...

Страница 6: ...n with the Scoop feature When using the Parametric Mid it s possible to enhance the Scoop s capabilities by letting the two tone shaping controls work in tandem If you like the added bottom of the Sco...

Страница 7: ...ed no output will be heard until the red Protect LED automatically shuts off In a rare case of amplifier shutdown or if the output is shorted the ampli fier will take approximately 15 20 seconds to re...

Страница 8: ...switch is enabled Effects return inch Jack This balanced jack is used to return effects processed audio signal back into the XS800H The Effects Return control located on the front panel regulates the...

Страница 9: ...ity mV 80 Master Outputs Speakon 1 4 inch x2 Line Out type configuration Pre Post EQ XLR Bal TRS Line Out Sensitivity Vrms 1 Effects Loop Location Rear Effects Footswitch Function Tube Drive Effects L...

Страница 10: ...Le contr le R sonance permet l obtention d un son de graves plus serr ou plus relaxe Contr les actifs de tonalit Cinq bandes Incluant un r glage de pr cision pour les m di anes param triques Raccorde...

Страница 11: ...SPEAKON Pin Configuration 1 1 Yorkville 230V 50Hz 2 5A 120VAC 60Hz 5 0A TYPE YS1035 Z666 PR1 1 GND Lift 800 1 Prises d entr es Passives et Actives 2 Commutateur de selection entre pr am plification T...

Страница 12: ...eur tournez le contr le dans le sens horaire jusqu ce que le point de seuil de d clenchement ait t atteint Cela sera apparent de fa on audible et aussi visible une DEL rouge situ e la droite du contr...

Страница 13: ...Hz Conseil Pour utiliser ce contr le r glez la position du contr le param trique de niveau pour m dianes pour obtenir une augmentation ou une r duction Tournez le contr le de fr quence jusqu ce que vo...

Страница 14: ...ent pour aider obtenir un son plus percutant Limiteur Commutable Pour pr venir l cr tage s v re de l amplificateur de puissance un limiteur commutable est pr vu Contr le Master Volume Le contr le Mast...

Страница 15: ...studio S lectionnez l option D I sur le s lecteur de mode D I Output situ sur le panneau avant pour obtenir un signal pr EQ et pr EFX S lectionnez l option Line pour un signal post EQ et post EFX Un c...

Страница 16: ...H est quip de deux ventillateurs de trois pouces Les ventilateurs tournent normalement vitesse r duite et leur vitesse augmente selon l emploi de l amplificateur de puissance Les conduits d entr e pou...

Страница 17: ...Pr Post EQ XLR Sym PBM Sensibilit de la Sortie Ligne Vrms 1 Boucle d effet Location Arri re Commutateur au pied pour effet Fonction Tube Drive Boucle d effet Sensibilit du retour d effet Vrms 1 DEL In...

Страница 18: ...800 16...

Страница 19: ...nable Input Compressor Threshold Adjust Gain Off Full Tuner Out Tube Solid State Select Switch 0 dB Mono 1 4 inch Stereo 1 4 inch 6 dB Low Mid Hi EQ Param Mid Freq Gain Hi Mid EQ BLOCK DIAG XS800H 01...

Страница 20: ...625 Witmer Industrial Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905...

Отзывы: