FORM 150.60-NM3
79
YORK INTERNATIONAL
FIELD INSTALLATION
If it becomes necessary to field install the Hot Gas
(Loadminder) Option, two kits are required. Order the kit
from the list below:
KIT, HOT GAS BYPASS (LOADMINDER)
MODEL
PART NUMBERS
NUMBER
STANDARD UNIT
UNIT WITH
REMOTE COOLER
YCAZ88EE8
375-04528-004
375-04529-004
YCAJ44HE8
375-04528-001
375-04529-001
YCAJ54HE8
375-04528-001
375-04529-001
YCAJ55HE8
375-04528-001
375-04529-001
YCAJ65HE8
375-04528-002
375-04529-002
In addition, a 471-01232-101 kit must also be ordered.
The 471-01232-101 kit consists of a second Relay Out-
put Board. It is not required if two Relay Boards are al-
ready installed in the control panel.
DISCHARGE PRESSURE READOUT OPTION
The Discharge Pressure Read-out Option P/N 471-
01262-111 allows the user to obtain control panel dis-
plays of discharge pressure. Additionally, other displays
such as fault information will then hold relevant discharge
pressure information useful in diagnosing problems.
The discharge pressure unloading feature also becomes
usable when this option is installed (Page 35) as well as
fan cycling by discharge pressure.
Fan cycling by discharge pressure sometimes becomes
necessary, if ambient temperature cycling of fans
causes low suction pressure faults due to unusual op-
erating conditions or chiller location problems. Fan cy-
cling by discharge pressure only, allows higher dis-
charge pressures which in turn raises suction pressure
by permitting better operation of the thermal expansion
valve. To convert to discharge pressure cycling, the mi-
cro panel must be programmed for DISCHARGE PRES-
SURE FAN CONTROL (See Page 29). Fan cycling will
operate as indicated in Table 3.
The kit consists of discharge pressure transducers for
each system, wire harnesses, and associated mounting
hardware.
HIGH AMBIENT OPTION
The High Ambient Option consists of two kits, P/Ns
471-01262-111 and 475-04250-000. The option allows
operation of the chiller in ambients up to 115°F. Typi-
cally, standard operation is limited to 105°F. High am-
bient operation is accomplished by discharge pressure
unloading to assure that the chiller does not fault due to
the high pressure cut-out opening during high tempera-
ture operation. A sun shield is also installed on the con-
trol panel to prevent direct sunlight from overheating the
control panel causing subsequent malfunction of the
electro-mechanical and electronic components in the
control panel. Additionally, actual discharge pressure
read-outs can now be obtained from the micro panel.
Discharge Pressure unloading allows the microproces-
sor to unload a compressor when the discharge pressure
approaches a point nearing the discharge pressure
cut-out. This assures that the system does not shut
down completely if the cut-out were to open. See Page
35 for programming the unloading pressure.
Fan cycling by discharge pressure is also available when
this option is installed (See DISCHARGE PRESSURE
READ-OUT OPTION, Page 79), however it is of little use
in areas where ambients are generally high and standard
temperature control of the fans provides good control and
maximum efficiency.
SYS
FAN
CONTACTOR
ON
OFF
1 REV
(Optional
7M
320 PSIG
120 PSIG
1
Low Ambient)
2
6M
340 PSIG
120 PSIG
1 FWD
5M
360 PSIG
140 PSIG
3 REV
(Optional
10M
320 PSIG
120 PSIG
2
Low Ambient)
4
9M
340 PSIG
120 PSIG
3 FWD
8M
360 PSIG
140 PSIG
TABLE 3
Содержание YCAZ88EE8
Страница 16: ...16 YORK INTERNATIONAL WIRING DIAGRAMS LD02165 FIG 5 ELEMENTARY DIAGRAM ...
Страница 17: ...FORM 150 60 NM3 17 YORK INTERNATIONAL FIG 5 ELEMENTARY DIAGRAM Cont d LD02166 ...
Страница 20: ...20 YORK INTERNATIONAL CONNECTION DIAGRAM ELECTRICAL BOX FIG 7 CONNECTION DIAGRAM LD02171 ...
Страница 21: ...FORM 150 60 NM3 21 YORK INTERNATIONAL FIG 7 CONNECTION DIAGRAM Cont d LD02172 ...