The Aurora Base Control System cont.
Add On Control Feature Kits
(factory installed)
Description
Aurora ‘Base’
Aurora 'Advanced'
Geo Energy Monitoring Kit
Monitors realtime power consumption of compressor, aux
heat and pump. AXB required.
-
Standard
Refrigeration Monitoring Kit
Monitors realtime pressures, temperatures, superheat, and
subcooling. AXB required.
-
Standard
Performance Monitoring Kit
Monitors water temperatures
-
Standard
Data Logging (AWL) Kit
Allows data logging of up to 12 months. Can also be tempo-
rarily installed for troubleshooting.
-
Optional
Service Device
Description
Aurora ‘Base’
Aurora 'Advanced'
Aurora Interface and Diagnostics
(AID) Tool
Allows setup, monitoring and troubleshooting of any
Aurora Control.
NOTE:
Although the ABC has basic compatibility with all Au-
rora, new product features may not be available on older AID
Tools. To simplify the basic compatibility ensure the version
of AID is at least the same or greater than the ABC software
version.
For Service
(Ver. 1.xx or greater)
For Service
(Ver. 2.xx or greater)
Add On Thermostats and Zoning
Description
Aurora ‘Base’
Aurora ‘Advanced’
HZO
Non-communicating controller for up to two heat pumps.
Standard
Standard