Wiring Schematics cont.
Aurora Advanced with 5-Speed ECM cont.
7/27/2015
1
2
3
L
N
G
5 Speed ECM
Blower Motor
C
4
5
Green
Orange
Brown
Current Transducer (CT)
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
K5 -
K6 -
CR3 -
CR4 -
F1 and F2 -
WCL -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW1 -
SW2 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Water Coil Limit Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 5 position AXB
TEST MODE ABC Board
DIP package 8 position ABC Board
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 -
Aux heat stage relays
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
CS -
Compressor Solenoid
Breaker
NOTE 3
P11
2
3
4
5
1
Green
Brown
Orange
NOTE 4
Violet
Blue
2
3
HE1
TS1
HE2
TS2
Black
Gray
Black
Gray
Green
P9
ER
1
ER
2
N
O
N
O
Brown
Orange
5
4
EA Series
PCB
P2
1
L2
L1
G
208-230/60/1
Green
P11
2
3
4
5
1
C
1
2
3
4
Brown
Orange
P1
4
1
2
3
C
G
G
To PB2
TB
ER
4
N
O
G
ER
3
N
O
G
Gray
Gray
Black
Black
Black
Gray
Gray
Black
NOTE 3
Connects to variable
speed ECM motor only
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
5 – Low voltage wiring CLASS 2.
3 – Jumpers wires are Factory Installed, and are
Required for auxiliary heat operation.
1 - Use copper or aluminum conductors.
2 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
P3 from unit’s control box
connects to P2
L1
L2
Single Disconnect Power
208-230/60/1
Aux Elect Power
208-230/60/1
L1
L2
L1
L2
Unit Power
208-230/60/1
CSA installed units only
Local codes may require a single
source of power supply
Breaker box
furnished by
installer
Circuit Breakers
4 - When installed the Auxiliary Heat powers blower and controls.
10 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
12 - Refer to units 5 SPEED ECM MOTOR LOW VOLTAGE CONNECTION table for
factory settings.
5 - Y2 input wire Tan not connected on Single Speed units. Wire is secured at blower.
6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 – Brown blower power wire routed through Current Transducer two times.
8 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
3 – When Auxiliary Heat is field installed the harness will be connected to the auxiliary
heat unit. The auxiliary heat unit will then power the blower. Refer to EAS/EAM/EAL
Auxiliary Heat kit installation instructions. Wires are secured at blower
9 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
11 - Field installed SPST relay required for dual fuel installation.
4 – Low voltage wiring CLASS 2.
13 – Ground wire only on units with aluminum air coils.
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
SD2500AK6 06/21
55