The furnace must be isolated from the gas supply piping system by
closing its individual external manual shutoff valve during any pressure
testing of the gas supply piping system at pressures equal to or less
than 0.5 psig (3.5 kPa).
Gas piping can be connected from either side of the furnace using any
of the gas pipe entry knockouts on both sides of the furnace. See Fig-
ures 6 and 10.
HIGH ALTITUDE
The TL9E060 furnace is constructed at the factory for natural gas-fired
operation at 0 to 7,800 ft (0 to 2,377 m) above sea level. No adjust-
ments are needed.
The TL9E080 and TL9E100 are constructed at the factory for natural
gas-fired operation at 0 to 5,000 ft (0 to 1,524 m) with no adjustments
needed. Above 5,000 ft (1,524 m), change the unit ID plug. Use the
following high altitude accessory kits: S1-32552070000 for TL9E080,
S1-32552071000 for TL9E100.
SECTION V: ELECTRICAL POWER
ELECTRICAL POWER CONNECTIONS
Field wiring to the unit must be grounded. Electric wires that are field
installed must conform to the temperature limitation for 63°F (35°C) rise
wire specified in these instructions. See Table 4 in these instructions for
specific furnace electrical data.
Notes:
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE test procedures.
Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace must be installed so the electrical components are protected from water.
Figure 10:
Gas Piping
UNION
UNION
HORIZONTAL
UPFLOW
DRIP
LEG
DRIP
LEG
MANUAL
SHUT-OFF
VALVE
TO GAS
SUPPLY
TO GAS
SUPPLY
UNION
TO
GAS
SUPPLY
DRIP
LEG
DRIP
LEG
UNION
TO
GAS
SUPPLY
MANUAL
SHUT-OFF
VALVE
A1123-001
IMPORTANT:
An accessible manual shutoff valve must be installed
upstream of the furnace gas controls and within 6 ft (1.8 m) of the fur-
nace.
CAUTION
The gas valve body is a very thin casting that cannot take any exter-
nal pressure. Never apply a pipe wrench to the body of the gas valve
when installing piping. A wrench must be placed on the octagon hub
located on the gas inlet side of the valve. Placing a wrench to the
body of the gas valve will damage the valve causing improper opera-
tion and/or the valve to leak.
!
CAUTION
Use copper conductors only.
!
Table 4:
Ratings and Physical/Electrical Data
Input
Output
Nominal
Airflow
AFUE
Air
Temperature
Rise
Maximum
Outlet
Air
Temperature
Blower
Blower
Size
Recommended
Fuse or Circuit
Breaker
Total
Unit
Gas Pipe
Connection,
NPT
MBH kW MBH kW
CFM m
3
/min
%
°F
°C
°F
°C
HP
A
in.
A
A
in.
60
17.6
57
16.7 1200
34.0
95.0 35–65 19–36
190
88
1/2
6.4
11x8
15
8.0
1/2
80
23.4
76
22.3 1600
45.3
95.0 35–65 19–36
190
88
3/4
8.8
11x10
15
10.4
1/2
100
29.3
95
27.8 2000
56.6
95.0 35–65 19–36
190
88
1
11.5
11x11
15
13.1
1/2