background image

246699-YTG-D-1208

Johnson Controls Unitary Products

37

FIGURE 11 - FACTORY INSTALLED DOWNFLOW ECONOMIZER

FIGURE 12 - FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST

2EE04705424

Fresh Air Hood

2EE04705424

Fresh Air Damper

2EE04705424

Return Air Damper

2EE04705424

Barometric Relief Damper

2EE04705424

Barometric Relief Hood

2EE04705424

Fresh Air Hood

2EE04705424

Fresh Air Damper

2EE04705424

Return Air Damper

2PE047032XX

Power Exhaust

2EE04705424

Barometric Relief Damper

2EE04705424

Barometric Relief Hood

Содержание Predator DF 078

Страница 1: ...ned for light commercial applications and can be easily installed on a roof curb slab or frame All DF Predator units are self contained and assembled on rigid full perimeter base rails allowing for 3...

Страница 2: ...COOLING CAPACITY DF120 10 TON UNIT 16 9 ELECTRICAL DATA DF078 6 1 2 TON MID EFFICIENCY W O PWRD CONVENIENCE OUTLET 17 10 ELECTRICAL DATA DF078 6 1 2 TON MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 17...

Страница 3: ...units use the same standard filter size This standard ization removes any confusion on which filter sizes are needed for replacement The non corrosive drain pan slides out of the unit to per mit easy...

Страница 4: ...he control board monitors the high and low pressure switches the freezestats the gas valve if applicable and the temperature limit switch on gas and electric heat units The unit con trol board will al...

Страница 5: ...ciency possible Horizontal Economizer Without barometric relief All features of the downflow economizer exist except you must order the duct mount baro metric relief separately You must order a 1EH040...

Страница 6: ...day scheduling is built in Two different modes of demand ventilation are achieved through the INTELLI Comfort using CO2 sensors It uses an inside CO2 sensor to perform Demand Ventilation It can also u...

Страница 7: ...r Exhaust This accessory installs in the unit with a down flow economizer Power exhaust plugs into the connector in the unit bulkhead You must purchase 1EH0408 barometric relief when applying to a hor...

Страница 8: ...tric Relief 1FA0414 Manual Outside Air Damper 0 100 Downflow Incl Hood Damper Filters No Barometric Relief 2MD04702724 Motorized Damper Downflow Incl Hood Damper Filter no Barometric Relief 2MD0470332...

Страница 9: ...Propane 1FE0412 Flue Exhaust Extension Kit 2BC04700106 Gas Heat Kit 60 deg F 230V 2BC04700151 Gas Heat Kit 60 deg F 460V 2BC04700154 Gas Heat Kit 60 deg F 575V 1FL0402 Permanent Filter Includes 4 Fou...

Страница 10: ...No Options Installed Installation Options B Option 1 C Option 2 D Options 1 2 E Option 3 F Option 4 G Options 1 3 H Options 1 4 J Options 1 2 3 K Options 1 2 4 L Options 1 3 4 M Options 1 2 3 4 N Opt...

Страница 11: ...rea ft 2 10 67 10 67 10 67 13 2 Condenser Fan 2 per Unit Propeller Dia in 24 24 24 24 Motor HP each 1 3 1 3 3 4 3 4 CFM Nominal each 3400 3400 4400 4400 Condenser Coil 2 per unit Rows 1 1 Sys 1 2 Row...

Страница 12: ...65 3 4 090 7 1 2 Cooling Only 87 10 5 11 6 2516 84 Electric Heat 18 36 Gas Heat 120 96 80 15 45 3 4 Gas Heat 180 144 80 30 60 3 4 102 8 1 2 Cooling Only 99 10 4 10 39 3055 84 Electric Heat 9 18 24 36...

Страница 13: ...6 1 50 5 45 0 39 4 33 8 28 3 52 8 7 05 52 8 52 6 47 1 41 5 36 0 30 4 24 8 2275 72 76 5 6 90 51 4 44 8 38 2 31 7 25 1 69 6 7 37 48 9 42 3 35 8 29 2 22 6 67 67 1 6 67 62 3 57 1 50 6 44 0 37 4 30 9 24 3...

Страница 14: ...33 6 93 4 8 4 65 6 56 8 48 1 39 3 30 6 67 92 4 7 7 85 8 77 0 68 3 59 5 50 8 42 0 33 3 84 1 8 2 80 8 73 8 65 1 56 3 47 6 38 8 30 1 62 84 8 7 5 84 8 84 8 82 6 73 9 65 1 56 4 47 6 77 7 8 0 77 7 77 7 76...

Страница 15: ...74 4 64 5 54 6 44 6 34 7 103 5 9 3 70 9 61 0 51 1 41 2 31 2 67 103 1 8 4 94 3 84 4 74 4 64 5 54 6 44 7 34 8 92 6 9 1 88 2 80 2 70 3 60 3 50 4 40 5 30 6 62 95 5 8 3 95 5 95 5 92 3 82 3 72 4 62 5 52 6 8...

Страница 16: ...1 1 97 6 10 34 96 2 87 7 79 1 70 6 62 0 53 5 44 9 3500 72 117 0 10 10 78 6 68 5 58 4 48 2 38 1 111 9 10 85 77 2 67 1 57 0 46 8 36 7 67 109 7 9 92 100 90 4 80 3 70 2 60 1 50 0 39 9 102 8 10 55 97 9 88...

Страница 17: ...s Min Circuit Ampacity Amps FLA 208 10 6 78 0 1 5 230 460 575 Voltage Compressors OD Fan Motors Supply Blower Motor FLA TABLE 10 ELECTRICAL DATA DF078 6 1 2 TON MID EFFICIENCY WITH PWRD CONVENIENCE OU...

Страница 18: ...r Exhaust Amps FLA FLA Actual KW Heater Amps Min Circuit Ampacity Amps MCA w Power Exhaust Amps 2 HP 3 HP 208 230 460 575 TABLE 12 ELECTRICAL DATA DF090 7 1 2 TON MID EFFICIENCY WITH PWRD CONVENIENCE...

Страница 19: ...r Exhaust Amps 3 HP 3 HP FLA FLA 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 3 HP 208 11 7 88 0 460 6 4 42 0 230 11 7 88 0 3 5 10 9 10 9 5 5 3 5 5 3 5 3 2 2 0 0 10 9 10 9 5 5 0 0 0 0 575 5 1 36 0 1 3 4 1 4 1 1...

Страница 20: ...Fuse Size w Power Exhaust Amps FLA Electric Heater Model No Actual KW Min Circuit Ampacity Amps Heater Amps FLA Voltage 208 Compressors OD Fan Motors Supply Blower Motor FLA Pwr Exh Motor 10 9 16 0 13...

Страница 21: ...ce includes dry coil and 2 throwaway filters Blower performance for gas heat includes the maximum number of heat tubes available for each tonnage ESP External Static Pressure given is that available f...

Страница 22: ...41 1 71 1597 1088 1 90 1770 2500 602 0 59 550 654 0 76 705 746 0 94 877 815 1 04 968 884 1 32 1232 934 1 47 1369 996 1 66 1544 1046 1 78 1655 1094 1 96 1827 2600 612 0 64 600 669 0 81 755 756 0 99 923...

Страница 23: ...907 1 11 1030 973 1 30 1216 1038 1 50 1396 1101 1 68 1565 1163 1 84 1718 1222 1 99 1851 1280 2 10 1960 1336 2 27 2113 1389 2 40 2238 1439 2 55 2374 3000 929 1 21 1131 995 1 41 1317 1060 1 61 1497 112...

Страница 24: ...1020 998 1 33 1243 1055 1 54 1433 1107 1 71 1596 1156 1 87 1740 1205 2 01 1869 1255 2 14 1991 1309 2 26 2111 1346 2 40 2235 3000 952 1 20 1122 1016 1 44 1345 1073 1 65 1535 1125 1 82 1698 1175 1 98 18...

Страница 25: ...2092 1032 2 50 2334 1080 2 64 2462 1127 2 2 93 2732 3800 746 1 46 1361 803 1 61 1505 853 1 76 1641 909 1 98 1841 956 2 15 2005 1002 2 35 2190 1041 2 60 2427 1086 2 74 2554 1132 2 3 04 2832 3900 759 1...

Страница 26: ...1 34 1253 969 1 53 1426 1013 1 69 1577 1047 1 82 1695 2500 743 0 9 828 801 1 08 1003 865 1 23 1148 906 1 41 1317 977 1 6 1491 1019 1 76 1641 1053 1 88 1755 2600 755 0 96 895 812 1 14 1063 875 1 3 1211...

Страница 27: ...26 1462 2 35 2192 1556 2 56 2388 2800 982 1 26 1178 1057 1 45 1355 1128 1 63 1524 1199 1 80 1674 1271 1 92 1794 1348 2 01 1875 1402 2 28 2128 1485 2 46 2294 1578 2 67 2490 2900 1007 1 38 1283 1082 1 5...

Страница 28: ...06 1 55 1441 1171 1 71 1597 1236 1 87 1739 1305 2 02 1878 1384 2 26 2102 1459 2 37 2209 1538 2 45 2282 2800 991 1 23 1149 1062 1 46 1364 1129 1 66 1544 1194 1 82 1700 1259 1 98 1842 1328 2 13 1981 140...

Страница 29: ...2 901 1 84 1715 953 2 04 1905 997 2 24 2092 1033 2 44 2270 1062 2 60 2425 3700 805 1 58 1474 860 1 74 1624 916 1 94 1812 965 2 15 2005 1007 2 35 2193 1041 2 54 2370 1069 2 71 2522 3800 824 1 68 1566 8...

Страница 30: ...rough the economizer is greater for 100 outdoor air than for 100 return air If the resistance of the return air duct system is less than 0 25 IWG the unit will deliver less CFM during full economizer...

Страница 31: ...E BELT HP RPM Eff SF Frame Datum Dia in Bore in Model Datum Dia in Bore in Model DF078 1 1 2 1725 80 1 15 56 3 4 4 4 7 8 1VM50 9 5 1 AK99 A58 2 1725 80 1 15 56 3 4 4 4 7 8 1VM50 7 5 1 AK79 A55 DF090 2...

Страница 32: ...3 DF102 38 23 DF120 47 1 2 25 1 2 D A C B LEFT FRONT X Y LEFT FRONT FIGURE 4 UNIT 6 POINT LOAD TABLE 32 6 POINT LOAD WEIGHT Model Locations lbs A B C D E F DF078 158 142 128 187 207 231 DF090 137 112...

Страница 33: ...ors Overhanging structure or shrubs should not obstruct condenser air discharge outlet 72 Right 12 Front 36 Left 36 Rear To remove the slide out drain pan a rear clearance of 60 is required If space i...

Страница 34: ...S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T I O N I N S U L A T E D D E C K U N D E R C O N D E N S E R S E C T I O N F R O N T R I G H T S U P P L Y R E T U R N FIGURE 7 SUNLINE TO PR...

Страница 35: ...3 32 16 3 8 18 1 16 12 5 16 6 13 16 24 21 LEFT Bottom gas supply entry Bottom Power Control and Convenience Outlet Wiring SUPPLY AIR RETURN AIR FRONT FIGURE 9 REAR DUCT DIMENSIONS Dot Plugs 18 1 4 5 5...

Страница 36: ...l Horizontal economizer without barometric relief 2EE04705524 Barometric relief must be ordered separately and installed in duct work ERV or End Return 42 Slab Economizer 42 tall cabinet 2EE04705624 B...

Страница 37: ...WER EXHAUST 2EE04705424 Fresh Air Hood 2EE04705424 Fresh Air Damper 2EE04705424 Return Air Damper 2EE04705424 Barometric Relief Damper 2EE04705424 Barometric Relief Hood 2EE04705424 Fresh Air Hood 2EE...

Страница 38: ...POWER EXHAUST 1EH0408 Barometric Relief Hood 1EH0408 Barometric Relief Damper 2PE047032XX Power Exhaust 2EE04705524 Fresh Air Hood 2EE04705524 Fresh Air Damper 2EE04705524 Return Air Damper Field Inst...

Страница 39: ...itary Products 39 FIGURE 15 SLAB ECONOMIZER END RETURN W POWER EXHAUST 2EE04705X24 Slab Economizer 1EH0409 Barometric Relief Hood 1EH0409 Barometric Relief Damper 1EH0409 Fresh Air Hood 2PE047032XX Po...

Страница 40: ...246699 YTG D 1208 40 Johnson Controls Unitary Products FIGURE 16 TYPICAL COOLING UNIT WITH GAS HEAT WIRING 230 VOLT DIAGRAM...

Страница 41: ...246699 YTG D 1208 Johnson Controls Unitary Products 41 FIGURE 17 TYPICAL COOLING UNIT WITH WITHOUT ELECTRIC HEAT WIRING DIAGRAM...

Страница 42: ...246699 YTG D 1208 42 Johnson Controls Unitary Products FIGURE 18 TYPICAL COOLING UNIT WITH GAS HEAT WIRING 460 575 VOLT DIAGRAM...

Страница 43: ...all be hinged with toolless access for easy servicing and maintenance Full perimeter base rails shall be provided to assure reliable transit of equipment overhead rigging fork truck access and proper...

Страница 44: ...ingle location through either the side or bottom without any field modifications An integrated control board shall provide timed control of evapo rator fan functioning and burner ignition Heating sect...

Страница 45: ...on the corner of the unit housing the compressors ELECTRIC HEAT Electric heaters range from 9kW to 54 kW and are available in all the voltage options of the base unit PHASE MONITOR Designed to preven...

Страница 46: ...246699 YTG D 1208 46 Johnson Controls Unitary Products...

Страница 47: ...246699 YTG D 1208 Johnson Controls Unitary Products 47...

Страница 48: ...change without notice Printed in U S A 246699 YTG D 1208 Copyright 2009 by Johnson Controls Inc All rights reserved Supersedes 246699 YTG C 0708 Johnson Controls Unitary Products 5005 York Drive Norma...

Отзывы: