This equipment is a relatively complicated apparatus. 

During rigging, installation, operation, maintenance, 

or service, individuals may be exposed to certain com-

ponents or conditions including, but not limited to: 

heavy objects, refrigerants, materials under pressure, 

rotating components, and both high and low voltage. 

Each of these items has the potential, if misused or 

handled improperly, to cause bodily injury or death. It 

is the obligation and responsibility of rigging, instal-

lation, and operating/service personnel to identify and 

recognize these inherent hazards, protect themselves, 

and proceed safely in completing their tasks. Failure 

to comply with any of these requirements could result 

in serious damage to the equipment and the property in 

IMPORTANT!

READ BEFORE PROCEEDING!

GENERAL SAFETY GUIDELINES

which it is situated, as well as severe personal injury or 

death to themselves and people at the site.
This document is intended for use by owner-authorized 

rigging, installation, and operating/service personnel. It 

is expected that these individuals possess independent 

training that will enable them to perform their assigned 

tasks properly and safely. It is essential that, prior to 

performing any task on this equipment, this individual 

shall have read and understood the on-product labels, 

this document and any referenced materials. This in-

dividual shall also be familiar with and comply with 

all applicable industry and governmental standards and 

regulations pertaining to the task in question.

SAFETY SYMBOLS

The following symbols are used in this document to alert the reader to specific situations:

Indicates a possible hazardous situation 

which will result in death or serious injury 

if proper care is not taken.

Indicates a potentially hazardous situa-

tion which will result in possible injuries 

or damage to equipment if proper care is 

not taken.

Identifies a hazard which could lead 

to damage to the machine, damage to 

other equipment and/or environmental 

pollution if proper care is not taken or 

instructions and are not followed.

Highlights additional information useful 

to the technician in completing the work 

being performed properly.

External wiring, unless specified as an optional connection in the manufacturer’s product line, is not 

to be connected inside the control cabinet. Devices such as relays, switches, transducers and controls 

and any external wiring must not be installed inside the micro panel. All wiring must be in accor-

dance with Johnson Controls’ published specifications and must be performed only by a qualified 

electrician. Johnson Controls will NOT be responsible for damage/problems resulting from improper 

connections to the controls or application of improper control signals. Failure to follow this warning 

will void the manufacturer’s warranty and cause serious damage to property or personal injury.

Содержание MILLENIUM 351-46

Страница 1: ...T YK chillers furnished with an optional Variable Speed Drive VSD TABLE OF CONTENTS VSD Style Variations 2 VSD Unit and Harmonic Filter Component Overview 2 VSD Control System Overview 7 Control Panel...

Страница 2: ...cument and any referenced materials This in dividual shall also be familiar with and comply with all applicable industry and governmental standards and regulations pertaining to the task in question S...

Страница 3: ...any work on the chiller REVISION NOTES Revisions made to this document are indicated in the following table These revisions are to technical information and any other changes in spelling grammar or f...

Страница 4: ...er section a three phase DC to AC inverter section and an output suppression network The AC to DC rectifier utilizes a semi converter formed by the connection of three SCR diode modules 1SCR 3SCR in a...

Страница 5: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 5 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 6: ...JOHNSON CONTROLS 6 FORM 160 00 O1 1020...

Страница 7: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 7...

Страница 8: ...sink temperature is also monitored using thermistor temperature sensor RT4 The Bus Isolator board 031 01624 utilizes three resistors on the board to provide a safe impedance between the DC link filter...

Страница 9: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 9 FIG 3A VSD INPUT CURRENT WITHOUT FILTER FIG 3B VSD INPUT CURRENT WITH FILTER LD02727 LD02726...

Страница 10: ...capacitors located on the phase bank assembly and the Filter logic board It provides the means to sense the positive midpoint and negative connection points of the filter s DC link VSD CONTROL SYSTEM...

Страница 11: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 11 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...JOHNSON CONTROLS 12 FORM 160 00 O1 1020 FIG 4 IEEE 519 FILTER OPTION...

Страница 13: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 13 LD02725...

Страница 14: ...f the VSD s cooling fans and pumps control of the pre charge contactor control of the semi converter gating and generation of the PWM firing pulses which are sent to the VSD gate driver and ultimately...

Страница 15: ...tz When the Filter is present these additional lines are available by scrolling INPUT KVA ___ TOTAL PWR FACTOR ____ INPUT V AB ___V BC ___V CA ___V INPUT CURR A ___A B ___A C ___A INPUT V THD A ___ B...

Страница 16: ...the vanes hit 100 If there is an increase in load while at this point the ACC will increase speed until the vanes are at 95 The ACC will then be allowed to continue to optimize the speed and vanes Su...

Страница 17: ...cur rent exceeds a given limit The motor current is sensed by the Current Transformers on the VSD output pole assemblies and the signals are sent to the VSD logic board for processing Maximum instant...

Страница 18: ...apacitors are wired in series to achieve a 900 VDC capability for the DC link It is important that the voltage be shared equally from the junction of the center or series capacitor con nection to the...

Страница 19: ...two microprocessors on the VSD logic board Message RUN RELAY FAULT Redundant run signals are generated by the Micropanel one via wire 24 and the second via the serial communica tions link Upon receip...

Страница 20: ...particular shutdown and its accompany ing message is generated if the filter s DC link voltage drops to a level less than 60 VDC below the filter DC link voltage setpoint The filter DC link voltage se...

Страница 21: ...DD level of 8 or less for the VSD system Astandard VSD less the optional filter typically has an input current TDD level on the order of 28 30 Message WARNING FILTER DATA LOSS This message is displaye...

Страница 22: ...age was intended as a check of the 519 logic board s internal triangle waveform generator However the accuracy of the measuring circuit on the board can have as much error as the generator it is tryin...

Страница 23: ...FORM 160 00 O1 1020 JOHNSON CONTROLS 23 NOTES...

Страница 24: ...ennsylvania USA 17349 1 800 524 1330 Subject to change without notice Printed in USA Copyright by Johnson Controls 2020 www johnsoncontrols com ALL RIGHTS RESERVED Form 160 00 O1 1020 Issue Date Octob...

Отзывы: