700699-YTG-B-0812
Johnson Controls Unitary Products
33
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
TCGF60S41S4(E)
INDOOR COIL MODEL NO.
FC/MC62
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
1600
1800
2000
ID
DB
(°F)
80 80
75
80
80
80 80 75
80
80 80 80
75 80 80
ID
WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
52.3
60.4
57.1
61.8
66.7
54.1
61.4
58.6
63.6
67.7
55.9
62.5
60.2
65.3
68.7
S.C.
51.1
46.8
40.1
39.0
31.5
52.9
49.5
42.1
41.0
32.6
54.7
52.1
44.2
43.0
33.7
KW
3.12
3.16
3.15
3.19
3.23
3.14
3.17
3.17
3.20
3.25
3.15
3.18
3.18
3.21
3.26
75
T.C.
50.2
57.2
54.7
59.5
64.2
51.9
58.4
56.3
61.0
65.4
53.6
59.5
57.8
62.6
66.6
S.C.
49.1
45.8
39.1
38.2
30.5
50.8
48.5
41.1
40.2
31.6
52.4
51.1
43.2
42.3
32.8
KW
3.62
3.66
3.65
3.68
3.72
3.63
3.66
3.66
3.69
3.73
3.65
3.67
3.67
3.70
3.73
85
T.C.
48.1
54.1
52.4
57.1
61.6
49.7
55.3
53.9
58.5
63.1
51.3
56.6
55.4
60.0
64.5
S.C.
47.0
44.8
38.0
37.3
29.5
48.6
47.4
40.1
39.4
30.7
50.2
50.1
42.2
41.5
31.9
KW
4.12
4.15
4.15
4.17
4.20
4.13
4.16
4.16
4.18
4.20
4.14
4.16
4.16
4.18
4.21
95
T.C.
46.0
50.9
50.1
54.7
59.1
47.5
52.3
51.6
56.0
60.7
49.0
53.6
53.0
57.3
62.4
S.C.
45.0
43.7
37.0
36.4
28.5
46.5
46.4
39.1
38.6
29.8
47.9
49.0
41.2
40.8
31.1
KW
4.61
4.65
4.65
4.66
4.68
4.62
4.65
4.65
4.67
4.68
4.63
4.65
4.65
4.67
4.68
105
T.C.
43.4
47.6
47.3
51.8
56.5
44.7
49.0
48.6
52.9
58.0
46.1
50.5
49.9
54.1
59.4
S.C.
42.4
42.5
35.8
35.3
27.4
43.8
44.8
37.9
37.5
28.7
45.1
47.2
40.0
39.6
30.0
KW
5.40
5.43
5.45
5.43
5.43
5.40
5.42
5.44
5.43
5.42
5.39
5.41
5.44
5.43
5.42
115
T.C.
40.8
44.3
44.6
48.9
54.1
42.0
45.9
45.7
50.0
55.3
43.3
47.5
46.9
51.0
56.6
S.C.
39.9
41.3
34.6
34.3
26.3
41.1
43.3
36.7
36.4
27.6
42.3
45.3
38.8
38.5
28.9
KW
6.17
6.20
6.22
6.18
6.15
6.15
6.17
6.21
6.17
6.14
6.13
6.15
6.20
6.16
6.14
125
T.C.
38.2
41.1
41.8
46.0
51.6
39.3
42.8
42.9
47.0
52.7
40.5
44.5
43.9
47.9
53.7
S.C.
37.4
40.1
33.4
33.3
25.2
38.5
41.8
35.5
35.3
26.5
39.6
43.5
37.5
37.4
27.8
KW
6.93
6.96
6.99
6.92
6.86
6.90
6.92
6.98
6.91
6.86
6.87
6.89
6.96
6.90
6.86
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Air Handlers
Coils
T.C.
S.C.
KW
–
FC/MC/PC60
0.97
0.95
0.99
–
FC/MC62
1.00
1.00
1.00
–
FC64
1.02
1.05
1.00
–
HD60
1.01
0.99
1.01
–
UC60
0.98
0.97
1.00
AHE60D
–
1.01
1.03
0.97
AHR60D
–
1.00
1.01
1.02
AHV60D
–
0.99
0.97
0.99
AV*60
–
0.99
0.97
0.99
MV20D
FC/MC60D
1.00
0.99
0.98
MV20D
FC/MC62D
1.01
1.03
0.99
MV20D
FC64D
1.03
1.05
0.99
MX20D
FC/MC60D
0.99
0.97
0.95
MX20D
FC/MC62D
1.02
1.03
0.96
MX20D
FC64D
1.03
1.06
0.95
Air Handlers
Coils
T.C.
S.C.
KW