332018-BTG-D-0208
4
Unitary Products Group
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of
interconnecting line tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evap adder for line set.
FC/MC/PC48D3X
–
–
–
702 + 12
703 + 9*
–
–
FC/PC60C3X
–
–
–
–
703 + 13
703 + 6*
2C + 0*
FC/MC/PC60D3X
–
–
–
–
703 + 13
703 + 6*
2C + 0*
MC61D3X
–
–
–
–
–
703 + 13
2C + 0
FC/MC62D3X
–
–
–
–
–
703 + 13
2C + 0
HC30A3X
2A + 0
–
–
–
–
–
–
HC36B3X
–
2A + 0
2A + 0
–
–
–
–
HC42C3X
–
–
–
702 + 9
703 + 6*
–
–
HC60D3X
–
–
–
–
703 + 13
703 + 6*
2C + 0*
HD24A3X
–
–
–
–
–
–
–
HD36B3X
–
2A + 0
2A + 0
702 + 5
–
–
–
HD48C3X
–
–
–
–
703 + 0*
703 + 0*
–
HD60D3X
–
–
–
–
–
–
2C + 0*
UC24A3X
2A + 0
–
–
–
–
–
–
UC24B3X
2A + 0
–
–
–
–
–
–
UC30A3X
2A + 0
–
–
–
–
–
–
UC30B3X
2A + 0
–
–
–
–
–
–
UC36A3X
–
–
2A + 0
–
–
–
–
UC36B3X
–
–
2A + 0
–
–
–
–
UC36C3X
–
–
2A + 0
–
–
–
–
UC42B3X
–
–
–
702 + 0
–
–
–
UC42C3X
–
–
–
702 + 0
–
–
–
UC48C3X
–
–
–
702 + 12
703 + 9*
–
–
UC48D3X
–
–
–
702 + 12
703 + 9*
–
–
UC60C3X
–
–
–
–
703 + 13
703 + 6*
2C + 0*
UC60D3X
–
–
–
–
703 + 13
703 + 6*
2C + 0*
AHP24B3X
2A + 0
–
–
–
–
–
–
AHP30B3X
–
2A + 0
2A + 0
–
–
–
–
AHP42C3X
–
–
–
702 + 9
–
–
–
AHP/SHP48D3X
–
–
–
–
703 + 13
703 + 6*
–
AHP/SHP60D3X
–
–
–
702 + 17
703 + 13
703 + 6
2C + 0
AV24B3X
2A + 0
–
–
–
–
–
–
AV36C3X
–
2A + 0
2A + 0
702 + 9
–
–
–
AV/SV48D3X
–
–
–
–
703 + 13
703 + 6
–
AV/SV60D3X
–
–
–
–
703 + 13
703 + 6
2C + 0
F*FP040
–
–
2A + 0
–
–
–
–
F4FV060H06T2C
–
–
–
–
–
703 + 6
0
FOOTNOTES:
1. A TXV kit must be used with these coils to obtain system performance.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
4. If no TXV is listed, the indoor coil has the correct valve factory installed.
* Does not achieve 14 SEER with PSC furnaces. For ratings, see technical guide or visit www.aridirectory.org/ari/unitary.html
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)
Outdoor Unit
HABE-F018S
HDBE-F024S
HCBE-F030S
HABE-F036S
HBBE-F042S
HBBE-F048S
HCBE-F060S
Required TXV
1
1TVM2A1
1TVM2A1
1TVM2A1
1TVM702
1TVM703
1TVM703
1TVM2C1
Factory Charge, lbs-oz
5 - 9
6 - 0
8 - 2
9 - 14
14 - 15
15 - 5
16 - 5
Indoor Coil
2,3
TXV
4
+ Charge Adder, Oz