332018-BTG-D-0208
Unitary Products Group
15
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
HBBE-F048S
INDOOR COIL MODEL NO.
FC/MC/PC/UC60
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1400
1600
1800
ID DB
85
80
70
85
80
70
85
80
70
ID WB
72
67
57
72
67
57
72
67
57
75
T.C.
53.3
49.5
45.5
54.3
50.2
46.4
55.2
51.0
47.3
S.C.
33.4
32.6
31.1
35.9
35.0
33.0
38.3
37.4
34.9
K.W
2.76
2.72
2.69
2.77
2.74
2.70
2.77
2.76
2.70
85
T.C.
51.2
47.7
43.9
52.0
48.4
44.8
52.8
49.1
45.7
S.C.
33.1
32.1
30.6
35.4
34.5
32.6
37.7
36.8
34.6
K.W
3.07
3.04
3.01
3.07
3.05
3.02
3.08
3.06
3.03
95
T.C.
49.0
45.9
42.4
49.7
46.5
43.2
50.3
47.2
44.1
S.C.
32.7
31.6
30.0
34.9
33.9
32.2
37.1
36.2
34.4
K.W
3.37
3.35
3.33
3.38
3.36
3.34
3.38
3.37
3.35
105
T.C.
46.6
43.5
40.1
47.3
44.1
40.8
48.0
44.7
41.6
S.C.
31.7
30.7
29.0
34.0
32.9
31.2
36.3
35.1
33.3
K.W
3.78
3.75
3.74
3.79
3.76
3.75
3.79
3.77
3.75
115
T.C.
44.1
41.1
37.8
44.9
41.6
38.4
45.6
42.2
39.1
S.C.
30.8
29.8
28.1
33.1
31.9
30.2
35.4
34.1
32.3
K.W
4.18
4.16
4.15
4.19
4.16
4.15
4.21
4.16
4.15
125
T.C.
41.7
38.7
35.5
42.5
39.2
36.0
43.3
39.7
36.6
S.C.
29.8
28.8
27.1
32.2
31.0
29.2
34.6
33.1
31.3
K.W
4.59
4.56
4.56
4.60
4.56
4.55
4.62
4.56
4.55
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
AHP/SHP48
–
1.00
0.99
1.07
AHP/SHP60
–
1.00
0.99
1.03
AV/SV48
–
1.02
1.03
0.91
AV/SV60
–
1.02
1.03
0.91
F*FV060
–
1.02
1.03
0.91
MA16C
FC/MC48C
0.97
0.98
1.04
MA16C
FC60C
1.00
1.00
1.07
MA20D
FC/MC48D
0.97
0.98
1.04
MA20D
FC/MC60D
1.00
1.00
1.07
MA20D
MC61D
1.01
1.01
1.04
MA20D
FC/MC62D
1.01
1.01
1.04
MV20D
FC/MC48D
0.99
0.98
1.02
MV20D
FC/MC60D
1.01
1.00
1.04
–
FC/MC/PC/UC48
0.97
0.98
1.04
–
HC48
0.97
0.96
1.04
–
HC60
0.99
1.00
1.06
–
HD48
0.97
0.96
1.04
–
HD60
0.99
1.00
1.06
–
MC61
1.01
1.01
1.04
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
(F,L)L8V*C20
FC/PC60C
1.00
1.00
1.03
(F,L)L8V*C20
MC60D
1.00
1.00
1.03
(F,L)L8V*C20
MC61D
1.01
1.01
1.04
(F,L)L8V*C20
FC/MC62D
1.01
1.01
1.04
FL9(C,V)*C20
FC/PC60C
1.00
1.00
1.03
FL9(C,V)*C20
MC60D
1.00
1.00
1.03
FL9(C,V)*C20
MC61D
1.01
1.01
1.04
FL9(C,V)*C20
FC/MC62D
1.01
1.01
1.04
FL9(C,V)*D20
FC/MC/PC60D
1.00
1.00
1.03
FL9(C,V)*D20
MC61D
1.01
1.01
1.04
FL9(C,V)*D20
FC/MC62D
1.01
1.01
1.04