background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PV9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY 
TWO STAGE VARIABLE 
UPFLOW FURNACES

UP TO 94% AFUE

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

036-21584-001 Rev. C (0205)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.

FEATURES

Two stage heating operation includes:

- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation

Provides increased comfort level & very quiet unit oper-
ation

Adjustable delay timer allows two stage operation with 
single stage thermostat

• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• High velocity filter and side -return filter rack provided for 

easy field installation.

• May be installed as either two-pipe (sealed combustion) 

or single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance 

or service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• ClimaTraK comfort system allows dealer to customize 

comfort settings based on regional location.

Содержание AFFINITY PV9A12N040UP11

Страница 1: ...ble speed ECM blower operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit amp requirement for easy repl...

Страница 2: ...E RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C 21 19 3 4 18 1 2 8 7 8 PV9...

Страница 3: ...80 52 75 49 11 x 8 1 2 7 7 20 45 75 PV9C16N080UP11 80 52 75 49 11 x 10 3 4 9 6 20 45 75 PV9C20N100UP11 100 65 93 60 11 x 11 1 12 8 20 45 75 PV9D20N120UP11 120 78 112 73 11 x 11 1 12 8 20 40 70 Models Max Outlet Air Temp Nominal Airflow Cabinet Width Total Unit AFUE Min Wire Size awg 75 ft One Way Approximate Operating Weight F CFM In Amps PV9A12N040UP11 165 1200 14 1 2 9 94 0 14 121 PV9B12N060UP11...

Страница 4: ... 1490 920 C A 1250 790 1290 790 D A 1310 810 1360 840 C C 1090 690 1140 690 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1045 740 1110 710 A Any 905 645 960 640 B Any 825 595 870 600 C Any 765 590 830 570 D Any 80 000 INPUT 3 Ton 80 000 INPUT 4 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1330 880 1490 990 ...

Страница 5: ...e number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop 3 Determine the External System Static Pressure ESP without the filter 4 Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static 5 If total ...

Страница 6: ...type filter and filter rack Attaches to the bottom of the furnace 1BR0314 For 14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must be made by qualified dis tributor or dealer personnel NOTE For high altitude conversion an orifice c...

Страница 7: ...036 21584 001 Rev C 0205 Unitary Products Group 7 NOTES ...

Страница 8: ...e without notice Printed in U S A 036 21584 001 Rev C 0205 Copyright by York International Corp 2005 All rights reserved Supersedes 036 21584 001 Rev B 1004 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Отзывы: