036-21584-001 Rev. C (0205)
Unitary Products Group
3
* ESP (External Static Pressure) .5" WC is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
ELECTRICAL AND PERFORMANCE DATA
Models
Input High/Low Output High/Low
Blower Size
Blower
Max.
Over-current
Protect
Air Temp. Rise
MBH
MBH
In.
HP
Amps
°F
PV9A12N040UP11
40/26
38/24
11 x 8
1/2
7.7
20
35 - 65
PV9B12N060UP11
60/39
56/36
11 x 8
1/2
7.7
20
40 - 70
PV9B12N080UP11
80/52
75/49
11 x 8
1/2
7.7
20
45 - 75
PV9C16N080UP11
80/52
75/49
11 x 10
3/4
9.6
20
45 - 75
PV9C20N100UP11
100/65
93/60
11 x 11
1
12.8
20
45 - 75
PV9D20N120UP11
120/78
112/73
11 x 11
1
12.8
20
40 - 70
Models
Max. Outlet
Air Temp.
Nominal Airflow
Cabinet Width
Total Unit
AFUE
Min. Wire Size
(awg) @ 75 ft.
One Way
Approximate
Operating Weight
°F
CFM
In.
Amps
%
PV9A12N040UP11
165
1200
14-1/2
9
94.0
14
121
PV9B12N060UP11
170
1200
17-1/2
9
93.2
14
135
PV9B12N080UP11
175
1200
17-1/2
9
92.5
14
142
PV9C16N080UP11
175
1600
21
12
92.8
14
157
PV9C20N100UP11
175
2000
21
14
92.8
12
164
PV9D20N120UP11
170
2000
24-1/2
14
93.2
12
180
BLK
WHT
GRN
BLK (HOT)
WHT (NEUTRAL)
GRN
NOMINAL
120 VOLT
LINE WIRING CONNECTIONS
SINGLE STAGE HEATING
THERMOSTAT CONNECTIONS
SINGLE STAGE HEATING AND TWO-STAGE COOLING
THERMOSTAT CONNECTIONS
ROOM
THERMOSTAT
FURNACE
CONTROL
CONDENSING
UNIT
TO AIR CONDITIONER
CONTROLS
R
W
G
Y1
C
R
G
C
COMMON T’STAT CONNECTION
Y2
Y1
W1/W
Y/Y2
ROOM
THERMOSTAT
FURNACE
CONTROL
CONDENSING
UNIT
TO AIR CONDITIONER
CONTROLS
R
W
G
Y
C
R
G
C
COMMON T’STAT CONNECTION
W1/W
Y/Y2
ROOM
THERMOSTAT
FURNACE
CONTROL
CONDENSING
UNIT
TO AIR CONDITIONER
CONTROLS
R
W1
W2
G
Y2
R
G
COMMON T’STAT CONNECTION
Y1
Y1
W1/W
C
C
W2
Y/Y2
TWO-STAGE HEATING AND TWO-STAGE COOLING
THERMOSTAT CONNECTIONS