036-21584-001 Rev. C (0205)

Unitary Products Group

3

* ESP (External Static Pressure) .5" WC is at furnace outlet ahead of cooling coil.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

NOTES: 

1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
5. Air flows above 1800 CFM require either return from two sides or one side plus bottom.

ELECTRICAL AND PERFORMANCE DATA

Models

Input High/Low Output High/Low

Blower Size

Blower

Max. 

Over-current 

Protect

Air Temp. Rise

MBH

MBH

In.

HP

Amps

°F

PV9A12N040UP11

40/26

38/24

11 x 8

1/2

7.7

20

35 - 65

PV9B12N060UP11

60/39

56/36

11 x 8

1/2

7.7

20

40 - 70

PV9B12N080UP11

80/52

75/49

11 x 8

1/2

7.7

20

45 - 75

PV9C16N080UP11

80/52

75/49

11 x 10

3/4

9.6

20

45 - 75

PV9C20N100UP11

100/65

93/60

11 x 11

1

12.8

20

45 - 75

PV9D20N120UP11

120/78

112/73

11 x 11

1

12.8

20

40 - 70

Models

Max. Outlet 

Air Temp.

Nominal Airflow

Cabinet Width

Total Unit 

AFUE

Min. Wire Size

(awg) @ 75 ft. 

One Way

Approximate

Operating Weight

°F

CFM

In.

Amps

%

PV9A12N040UP11

165

1200

14-1/2

9

94.0

14

121

PV9B12N060UP11

170

1200

17-1/2

9

93.2

14

135

PV9B12N080UP11

175

1200

17-1/2

9

92.5

14

142

PV9C16N080UP11

175

1600

21

12

92.8

14

157

PV9C20N100UP11

175

2000

21

14

92.8

12

164

PV9D20N120UP11

170

2000

24-1/2

14

93.2

12

180

BLK

WHT

GRN

BLK (HOT)

WHT (NEUTRAL)

GRN

NOMINAL
120 VOLT

LINE WIRING CONNECTIONS

SINGLE STAGE HEATING

THERMOSTAT CONNECTIONS

SINGLE STAGE HEATING AND TWO-STAGE COOLING

THERMOSTAT CONNECTIONS

ROOM
THERMOSTAT

FURNACE
CONTROL

CONDENSING
UNIT

TO AIR CONDITIONER
CONTROLS

R

W

G

Y1

C

R

G

C
COMMON T’STAT CONNECTION

Y2

Y1

W1/W

Y/Y2

ROOM
THERMOSTAT

FURNACE
CONTROL

CONDENSING
UNIT

TO AIR CONDITIONER
CONTROLS

R

W

G
Y
C

R

G

C

COMMON T’STAT CONNECTION

W1/W

Y/Y2

ROOM
THERMOSTAT

FURNACE
CONTROL

CONDENSING
UNIT

TO AIR CONDITIONER
CONTROLS

R

W1
W2

G

Y2

R

G

COMMON T’STAT CONNECTION

Y1

Y1

W1/W

C

C

W2

Y/Y2

TWO-STAGE HEATING AND TWO-STAGE COOLING

THERMOSTAT CONNECTIONS

Содержание AFFINITY PV9A12N040UP11

Страница 1: ...ble speed ECM blower operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit amp requirement for easy repl...

Страница 2: ...E RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C 21 19 3 4 18 1 2 8 7 8 PV9...

Страница 3: ...80 52 75 49 11 x 8 1 2 7 7 20 45 75 PV9C16N080UP11 80 52 75 49 11 x 10 3 4 9 6 20 45 75 PV9C20N100UP11 100 65 93 60 11 x 11 1 12 8 20 45 75 PV9D20N120UP11 120 78 112 73 11 x 11 1 12 8 20 40 70 Models Max Outlet Air Temp Nominal Airflow Cabinet Width Total Unit AFUE Min Wire Size awg 75 ft One Way Approximate Operating Weight F CFM In Amps PV9A12N040UP11 165 1200 14 1 2 9 94 0 14 121 PV9B12N060UP11...

Страница 4: ... 1490 920 C A 1250 790 1290 790 D A 1310 810 1360 840 C C 1090 690 1140 690 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1045 740 1110 710 A Any 905 645 960 640 B Any 825 595 870 600 C Any 765 590 830 570 D Any 80 000 INPUT 3 Ton 80 000 INPUT 4 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1330 880 1490 990 ...

Страница 5: ...e number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop 3 Determine the External System Static Pressure ESP without the filter 4 Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static 5 If total ...

Страница 6: ...type filter and filter rack Attaches to the bottom of the furnace 1BR0314 For 14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must be made by qualified dis tributor or dealer personnel NOTE For high altitude conversion an orifice c...

Страница 7: ...036 21584 001 Rev C 0205 Unitary Products Group 7 NOTES ...

Страница 8: ...e without notice Printed in U S A 036 21584 001 Rev C 0205 Copyright by York International Corp 2005 All rights reserved Supersedes 036 21584 001 Rev B 1004 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Отзывы: