810753-UTG-A-0313
Johnson Controls Unitary Products
9
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during
the same period.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the RGF1L*P and RGF19*P, use Coil Only Ratings.
— = Not Applicable.
HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL
COIL
1
MODEL
HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
13 SEER HP COIL ONLY RATINGS
RHP13J184S21
FC/MC/PC18
18.0
3.36
1.50
12.7
2.16
1.24
8.20
FC/MC/PC24
18.0
3.36
1.45
10.4
2.60
1.17
8.20
FC/MC/PC30
18.0
3.42
1.54
11.4
2.18
1.53
7.75
UC24
18.0
3.42
1.54
11.4
2.20
1.52
7.75
UC30
18.0
3.42
1.54
11.4
2.20
1.52
7.75
RHP13J244S21
FC/MC/PC32
24.0
3.36
2.09
13.9
2.38
1.71
7.70
FC/MC/PC35
23.8
3.32
2.10
13.9
2.36
1.73
7.70
FC/MC/PC37
24.0
3.44
2.04
14.1
2.42
1.71
7.70
FC/MC/PC43
24.0
3.44
2.04
14.1
2.42
1.71
7.70
RHP13J304S21
FC/MC/PC32
27.4
3.28
2.45
16.0
2.30
2.04
7.70
FC/MC/PC35
27.4
3.28
2.45
16.0
2.30
2.04
7.70
FC/MC/PC37
28.0
3.38
2.43
16.1
2.32
2.03
7.70
FC/MC/PC43
28.0
3.38
2.43
16.1
2.32
2.03
7.70
RHP13J364S21
FC/MC/PC37
34.4
3.42
2.95
22.4
2.62
2.51
7.70
FC/MC/PC43
34.6
3.40
2.98
22.2
2.60
2.50
7.70
FC/MC/PC48
34.8
3.44
2.96
22.6
2.64
2.51
7.70
UC48
35.0
3.52
2.91
22.4
2.62
2.51
7.70
RHP13J424S21
FC/MC/PC60
40.5
3.72
3.19
23.0
2.50
2.70
7.70
UC60
40.0
3.68
3.18
22.8
2.48
2.69
7.70
RHP13J484S21
FC/MC/PC60
46.0
3.58
3.76
27.4
2.76
2.91
7.70
FC/MC62
46.0
3.54
3.81
27.4
2.76
2.91
7.70
UC60
46.0
3.56
3.79
27.4
2.74
2.93
7.70
RHP13J604S21
FC/MC62
58.0
3.44
5.24
39.5
2.66
4.35
7.80
FC64
58.0
3.36
5.49
40.5
2.76
4.30
7.80
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
HEATING CAPACITY - With High Efficiency Motor Furnaces
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3
RHP13J184S21
R*L*AE12
FC/MC/PC18A
18.0
2.92
1.81
11.1
2.24
1.45
8.10
R*L*AE12
FC/MC/PC24A
18.0
3.16
1.67
10.9
2.44
1.31
8.20
R*L*AE12
FC/MC/PC30A
18.0
3.16
1.67
10.9
2.44
1.31
8.20
R*L*AE12
UC18B 18.0
3.60
1.55
11.1
2.26
1.44
8.20
R*L*AE12
UC24B 18.0
3.68
1.50
11.1
2.02
1.61
8.15
R*L*AE12
UC30B 18.0
3.68
1.50
11.1
2.02
1.61
8.15
R*L*BE12
FC/MC/PC18B
18.0
3.00
1.76
11.0
2.28
1.41
8.15
R*L*BE12
FC/MC/PC24B
18.0
3.16
1.67
10.9
2.44
1.31
8.20
R*L*BE12
FC/MC/PC30B
18.0
3.16
1.67
10.9
2.44
1.31
8.20
R*L*BE12
UC18B 18.0
3.58
1.56
11.1
2.24
1.45
8.20
R*L*BE12
UC24B 18.0
3.66
1.52
11.0
2.34
1.38
8.10
R*L*BE12
UC30B 18.0
3.66
1.52
11.0
2.34
1.38
8.10
For Notes See Page 11.