background image

271042-UUM-A-0407

10

Unitary Products Group

ITEM

DESCRIPTION

MOTOR

1

MOTOR/MODULE, ECM PROGRAMMED (Complete)

1A

MODULE, ECM PROGRAMMED (Module only)

1B

Motor, ECM (less ECM module)

2

MOTOR, INDUCER ASSY

ELECTRICAL

3
4

SWITCH, LIMIT (INDUCER)

5

CONTROL, HIGH LIMIT

6

CONTROL, FLAME ROLL OUT

7

CONTROL, FURNACE

8

SWITCH, AIR PRESSURE

9

IGNITER

10

SENSOR, FLAME

11

SWITCH, DOOR

12

TRANSFORMER

13

VALVE, GAS

13A

CHOKE, PFC

AIR MOVING

14

HOUSING, BLOWER

15

WHEEL, BLOWER

FABRICATED PARTS

16

MOUNT, MOTOR

17

COIL,

 

CONDENSING

18

SHELF, BLOWER

19

BURNER, GAS

20

HEAT EXCHANGER ASS’Y

21

PANEL, BOTTOM

22

MANIFOLD, GAS

23

DOOR, VEST ACCESS, (Upper) (Magnet)

24

DOOR, BLOWER ACCESS (Lower) (Magnet)

25

WRAPPER, INSULATED

26

CHANNEL, TOE PLATE

27

PANEL, TOP

28

PLATE DIFFUSER

29

COVER,  GAS CONTROL

30

WRAPPER, BURNER BOX

31
32

BRACKET, IGNITER

33

PAN, SHIELD

34

PANEL, BLOWER ACCESS

35

BRACKET, BLOWER MTG (2 Req’d)

36

37
38
39

MISCELLANEOUS

40
41

RESTRICTOR, COMBUSTION BLWR

42

GASKET, COMBUSTION BLOWER

43

GASKET, CONDENSATE PAN

44

GASKET, CONDENSING COIL 

45

GASKET, GAS CONTROLS

46

GASKET, UPPER COND. PAN (2 Req’d)

47

GASKET, COMBUSTION AIR TRANSITION

48

GROMMET, MANIFOLD SEAL

49

PLUG, WINDOW, CLEAR - 1.5”

50

GROMMET, MOTOR MOUNT (3 Req’d)

51

FERRULE, MOTOR MOUNT (3 Req’d)

52

PAN, CONDENSATE

53

ORIFICE, BURNER (Natural #45)

54

TRAP, CONDENSATE 

55

WIRING DIAGRAM 

56

HARNESS, MAIN WIRING

57

HOSE ASSY, DRAIN

58

TUBE, PRE-FORMED

59

TUBE, DRAIN, CONDENSATE PAN

60

TUBE, DRAIN, CONDENSATE PAN

61

TUBE, DRAIN COMBUSTION BLWR

62

TUBE, SILICONE RUBBER (2 Ft. Req’d)

63

TUBE, VENT PIPE

64

TUBE, STRAIGHT DRAIN 21”

65

TUBE , RAIN GUTTER DRAIN

66

TUBE, CONDENSTE TRAP DRAIN

67

PIPE VENT ASSEMBLY

68

TRANSITION, 3-WAY

69

45 DEG ELBOW

70

VENT PIPE, 15.25” LG.

71

BUSHING

72

INSERT, ADAPTER

73

LOCKNUT, 1/2”

74

DOOR KNOB-BLACK (4 Req’d) (Magnet)

75

SIGHT GLASS, OVAL

76

TUBE, RESTRICTOR

77

MAGNET, DOOR (4 Req’d)

78

HARNESS, MOTOR WIRING (16 Pin)

ITEM

DESCRIPTION

NOTE:

*Not Shown

Major components and suggested stocking items are shown with shaded item number.

Содержание FC9V DH Series

Страница 1: ...deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone including cell phone in your...

Страница 2: ...nace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the furnace casing for obvious signs of deterioration 6 Examine the burner flames to make sure they are in good adjust ment Refer to the pictorial sketch shown in Figure 2 as a compari son to th...

Страница 3: ...ructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 7 Move gas control switch to t...

Страница 4: ...hed to the cas ing of the furnace or placed in the return air duct You can gain access to the filter by pulling on the door or unscrewing the retaining screw then slide the filter s out of its channel Replace throw away filter s with the same size new filter s Throw away filter s may be replaced with cleanable filter s at this time Cleanable filter s may be cleaned as described in the manufacturer...

Страница 5: ...nd the rear heat exchanger tubes Then vacuum loose the scale and dirt from each tube 9 Replace all components in reverse order Reconnect all wiring 10 Restore electrical power and gas supply to the furnace 11 Check furnace operation Cleaning the Secondary Heat Exchanger 1 Follow steps 1 7 under cleaning the Heat Exchanger 2 Remove the vent piping from the vent blower housing Disconnect the drain l...

Страница 6: ...The thermostat opens the R to Y and R to G circuits The Outdoor Unit is de energized The 60 second Blower Off Delay timing circuit is initiated After 60 seconds the Cool and EAC relays are de energized CONTROL BOARD Variable speed motors will adjust the motor speed in order to maintain the indoor fan CFM The control board is used to control the blower speed thus the CFM when the unit is operating ...

Страница 7: ... a higher speed will take 30 seconds and any ramp down to a lower speed or off will take 60 seconds Tap D is the normal profile best suited for most of the country where neither excessive humidity nor extremely dry conditions are the norm On a call for cooling the motor will ramp up to 63 of full capacity and will stay there for 90 seconds then will ramp up to full capacity At the end of the cooli...

Страница 8: ...out Low gas pressure faulty gas valve faulty hot surface ignitor or burner problem may cause this The furnace will lock out for one hour and then restart 8 RED FLASHES This fault is indicated if the flame is lost 5 times 4 recycles during the heating cycle This could be caused by low gas pressure or faulty gas valve The furnace will lock out for one hour and then restart 9 RED FLASHES Indicates re...

Страница 9: ...ucts Group 9 SECTION III REPLACEMENT PARTS LIST 70 34 57 2 59 61 54 5 26 68 8 52 62 12 7 25 27 13A 26 51 25 71 1 15 50 51 18 17 20 45 68 47 49 29 13 5 8 35 52 4 2 41 42 43 46 44 16 14 3 10 13 34 9 6 19 22 28 29 32 31 48 53 58 62 49 ...

Страница 10: ... 39 MISCELLANEOUS 40 41 RESTRICTOR COMBUSTION BLWR 42 GASKET COMBUSTION BLOWER 43 GASKET CONDENSATE PAN 44 GASKET CONDENSING COIL 45 GASKET GAS CONTROLS 46 GASKET UPPER COND PAN 2 Req d 47 GASKET COMBUSTION AIR TRANSITION 48 GROMMET MANIFOLD SEAL 49 PLUG WINDOW CLEAR 1 5 50 GROMMET MOTOR MOUNT 3 Req d 51 FERRULE MOTOR MOUNT 3 Req d 52 PAN CONDENSATE 53 ORIFICE BURNER Natural 45 54 TRAP CONDENSATE ...

Страница 11: ...ENT TERMINATION KIT 2 ALL MODELS 1CB0317 COMBUSTIBLE FLOOR BASE 17 1 2 CABINET 1CB0321 21 CABINET 1CB0324 24 1 2 CABINET 1TK0917 COIL TRANSITION KIT 17 1 2 CABINET 1TK0921 21 CABINET 1TK0924 24 1 2 CABINET REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete parts list refer to the contact information below Visit our website at www source1parts com for the follow...

Страница 12: ...271042 UUM A 0407 12 Unitary Products Group SECTION IV WIRING DIAGRAM FIGURE 8 Wiring Diagram ...

Страница 13: ...271042 UUM A 0407 Unitary Products Group 13 NOTES ...

Страница 14: ...271042 UUM A 0407 14 Unitary Products Group NOTES ...

Страница 15: ...271042 UUM A 0407 Unitary Products Group 15 NOTES ...

Страница 16: ...nly to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing 3 Damages resulting from accident abuse fire flood alteration or acts of God tampering altering defacing or removing the product serial number will serve to void this warranty 4 Damages resulting...

Отзывы: