7. Cleaning and maintenance
• Turn off the device and disconnect it from the external power supply before each cleaning.
• The device must not be cleaned under running water.
• Do not use aggressive cleaning agents for cleaning.
• Clean the outside and inside of the device with a damp cloth without the control panel, power section, modular battery socket or ventilation
openings. All sections mentioned above clean with dry and soft cloth.
• Manual defrosting
During long-term operation of the device, a layer of frost may appear inside it. This can reduce its performance.
To defrost the device, disconnect it from the power supply, empty the cooling compartment and leave the door open. After frost has condensed,
wipe off the remaining water with a soft cloth.
8. Troubleshooting
the most common faults
Foodstuffs have been frozen:
• Change the cooling temperature to higher, the set temperature is too low.
The device makes a sound of flowing liquid:
• This sound is normal.
Droplets of liquid appear around the fridge door:
• Liquid droplets appear due to the temperature difference between the device and its surroundings, and are normal.
When starting the device, the compressor makes a loud noise:
• It is normal for the compressor to work loudly at start-up
The device does not work:
• Check if the device has been switched on with the button .
• Check that the device is correctly connected to the power source.
• Check whether the power supply is functional.
• Check if the fuse has blown.
The device displays the F1 code:
• Code informing about 12 / 24V supply voltage drop. Change the protection setting to lower from H (high) to M (medium) or
from M (medium) to L (low).
The device displays the F2 code:
• Code informing about fan overload. Switch the device off and on again after 30 minutes.
The device displays the F3 code:
• Code informing about activation of protection against too frequent compressor operation. Switch the device off and on again after 30 minutes.
The device displays the F4 code:
• Code informing about compressor overload. Switch the device off and on again after 30 minutes.
The device displays the F5 code:
• Code informing about compressor module overheating. Switch the device off and on again after 30 minutes.
The device displays the code F6:
• Code informing about the inability to read parameters by the device controller. Restart the device. If the problem persists, please contact your
dealer.
The device displays the code F7 or F8:
• Code informing about temperature sensor error. Please contact the seller.
15 A
102mV
4.8 mΩ
340 A²s
Fuse specification
• Replacing the fuse
CAUTION! Before replacing the fuse, turn the device off
and disconnect it from the power supply.
1. Remove the fuse cover located in the immediate vicinity
of the power socket.
2. Remove the fuse and replace it with a new one with the
same technical parameters.
3. Reinstall the fuse cover.
Current Rating
Voltage Drop
Cold Resistance
I2t