Hint: Determine your blood pressure based on each measurement and the blood pressure table, and 

consult your doctor. 

3)  Take off the cuff from your arm and turn off the device by press the User1 “ ” or User2 “ ” button. (If there 

is no operation for 60 seconds, the device will be automatically off.) 

 

 

 

6.3 Prompt function of irregular heartbeat 

This monitor can detect the situation of irregular heartbeat. In the measuring process, if the appearance of this "

" symbol signifies that an irregular heartbeat was detected, it means that the result may deviate from your 

normal basal blood pressure. This indicator is only a caution, it is important that you be relaxed, remain still and 
do not talk during measurements. Please repeat the measurement. 

 

An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm 
detected while your monitor is measuring blood pressure. If the "

" symbol appears more frequently (e.g. 

several times per week on measurements performed daily) or if it suddenly appears more often than usual, we 
recommend you to consult with and follow directions of your physician. 

Note:   

If you have severe arrhythmia, it is very likely that you will not be able to measure the blood pressure. 

 

6.4 Voice broadcast 

Broadcast state 

Broadcast content 

Start measure 

Start measuring now 

Finish measurement 

The result of this measurement is XX, systolic blood pressure is XX, diastolic blood 
pressure is XX, and pulse is XX beats per minute, I wish you a good health, thank you 
for using 

Measurement failure 

The measurement failed, please try to wear the cuff and start a new measurement 
again 

Memory broadcast 

Systolic blood pressure was XX, diastolic blood pressure was XX, and pulse was XX 
beats per minute, I wish you a good health, thank you for using 

Low battery 

Low battery

Please charging the device soon 

Note: XX is the voice content corresponding to the measured actual value. 

 

6.5 Memory Function 

6.5.1 Check the measurement records 

1) In the shutdown state, press memory button “

” enter memory mode. 

Emergency stop! 

Stop the measurement in emergency condition: 
In the process of measurement, if the subject feels uncomfortable or needs to interrupt the measurement 
due to some other reasons, please press the user1/2 button, the machine will stop the measurement 
immediately and quickly discharge the air in the cuff to reduce the pressure. If the user1/2 button fails, 
please unfasten the cuff and stop the measurement. 

Содержание SP10A

Страница 1: ...Page 1 35 Upper Arm Blood pressure Monitor User Manual Model SP10A SP10B SP10C...

Страница 2: ...URE 7 4 Product introduction 8 5 Charging battery 11 6 Directions for use 12 7 Clean the monitor and cuff 24 8 Calibration and maintenance 25 9 Error indicators and troubleshooting 25 10 Storage 26 11...

Страница 3: ...individual Measurement environment hospital and home Intended placement of the cuff upper left arm Intended users 1 Adult 2 Have 9 years intensive reading experience 3 Can be read and understand the u...

Страница 4: ...e do not place heavy objects on it do not bind twist when using Otherwise it may cause fire or electric shock Please unplug the power plug before servicing this product Otherwise there will be danger...

Страница 5: ...r intravenous drip and blood transfusion Otherwise symptoms may worsen Other Cautions Do not disassemble or repair or modify the main unit and cuff of the blood pressure monitor Otherwise it cannot be...

Страница 6: ...ged impairment of the circulation of the blood of the patient Too frequent measurements can cause injury to the patient due to blood flow interference Do not apply of the cuff and its pressurization o...

Страница 7: ...ea Talking during measurement When nervous or emotionally unstable measurement with the posture of abdominal compression Body movement during measurement When room temperature changes rapidly When the...

Страница 8: ...unit and cuff 4 2 LCD display The display will be different for different models as shown in the table below Display Backlight Applicable Model VA LCD Yes SP10A TN LCD Yes SP10B TN LCD No SP10C 4 3 C...

Страница 9: ...mmHg 6 7 36 0 kPa Diastolic Blood Pressure 30 220 mmHg 4 0 29 3 kPa Pulse 40 180 beats minute Accuracy Pressure 3mmHg 0 4kPa Pulse 5 Resolution ratio 1mmHg 0 133kPa Pressure displayed range 0 290mmHg...

Страница 10: ...nd to WiFi via Bluetooth 3 After the measurement is completed the device will check whether WiFi is bound If WiFi is bound the data will be automatically uploaded to the corresponding user account of...

Страница 11: ...ice in time Charge the battery as below Connect the USB line to the power adapter then insert another end of USB line to the Charge hole of device then insert Power adapter plug into supply power sock...

Страница 12: ...onitor and battery Whenever the device is not used frequently charge the battery once a month 6 Directions for use 6 1 System setting 1 Unit setting Keeping press the user 1 button about 3s the LCD wi...

Страница 13: ...mory button to increase the cycle of the minute press the user 2 button to confirm and finish the setting 6 After setting the LCD will display done and enter sleep mode 2 seconds later 7 In the date t...

Страница 14: ...LCD shows it means that it is worn correctly and you can continue to measure If is displayed it means incorrect wearing Please wear it again according to the above requirements 6 2 2 Correct measuring...

Страница 15: ...rement procedure 1 After the cuff has been appropriately positioned press the User1 or User2 button to turn on the device the LCD will fully display for 1s and then enter measure mode Before the measu...

Страница 16: ...e If you have severe arrhythmia it is very likely that you will not be able to measure the blood pressure 6 4 Voice broadcast Broadcast state Broadcast content Start measure Start measuring now Finish...

Страница 17: ...down the monitor will shut down automatically after 1 minute Automatic replacement For each user group if the stored measurement results exceed 99 groups the oldest historical data will be automatical...

Страница 18: ...oad and Installation Search Runcobo note in the App Store or other App markets to download and install the App 6 6 2 APP installation Click get to install after verification After the installation is...

Страница 19: ...APP Registration After installed the APP open it and then complete registration follow the instruction on APP interface 6 6 4 Connect with APP and blood pressure monitor via Bluetooth 1 Turn on the B...

Страница 20: ...or a Click Add Blood Pressure Monitor and wait for the monitor to connect with APP as below figure b Turn on the monitor and start measure the blood pressure When the measurement is finished the blood...

Страница 21: ...d pressure monitor until the binding completed as below 6 6 5 Connect with APP and blood pressure monitor via WiFi 1 Select 2 4GHz WiFi to connect as below figure 2 Enter the WiFi password and wait fo...

Страница 22: ...lood pressure When the measurement is finished the blood pressure value is displayed on the LCD of monitor and then APP will search the monitor automatically When the APP connect with the monitor comp...

Страница 23: ...e the historical data follow below figure 6 6 7 FAQ Click the FAQ on APP interface to see the help for frequently asked questions as below figures XXX 6 6 8 APP update 1 Click on the avatar on the hom...

Страница 24: ...update to update 3 When update changes to open it means the update is complete click open to open the app 7 Clean the monitor and cuff Clean the monitor and wrist cuff 1 Make sure the monitor is off...

Страница 25: ...curacy of measurement please do not disassemble or modify the Upper Arm Blood Pressure Monitor without permission If you find quality problems please call the customer service hotline 9 Error indicato...

Страница 26: ...ge environment store in accordance with the storage environment conditions specified in this manual avoid moisture high temperature falling dust sun exposure vibration chemicals or corrosive gas etc 1...

Страница 27: ...int in the EU countries 2002 96 EC WEEE Directive If you have any queries please refer to the local authorities responsible for waste disposal NOTES Handing of battery and wastes method please act acc...

Страница 28: ...er Manual 15 Electromagnetic Compatibility Statement The equipment with following ESSENTIAL PERFORMANCE is intended used in Home healthcare environment and professional healthcare facility environment...

Страница 29: ...used at entrances or exits of department stores libraries and other public places and airport security screening devices may affect the monitor Additionally RFID devices which are often used to read...

Страница 30: ...tomer or the user of the upper arm blood pressure monitor should assure that it is used in such an environment Immunity test IEC 60601 1 2 test level Compliance level Electromagnetic environment guida...

Страница 31: ...40 66 MHz to 40 70 MHz The amateur radio bands between 0 15 MHz and 80 MHz are 1 8 MHz to 2 0 MHz 3 5 MHz to 4 0 MHz 5 3 MHz to 5 4 MHz 7 MHz to 7 3 MHz 10 1 MHz to 10 15 MHz 14 MHz to 14 2 MHz 18 07...

Страница 32: ...s equipment IEC 61000 4 3 See the following table Complies Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment Test frequency MHz Band a MHz Service a Modulationb M...

Страница 33: ...age caused by force majeure such as natural disasters such as earthquake fire etc When you need warranty service please show your warranty card If you can t show your warranty card or prove that the p...

Страница 34: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However the...

Страница 35: ...na Tel 86 755 21635022 Customer service hotline 86 400 998 2913 service time 9 00 to 21 00 of working day Email service yolanda hk Website www yolanda hk Document No 20210501V1 0 User manual Edition V...