76-QD7913EN-00Y00-03.doc
21
7.1.2. Setting items for every work
START TRQ
Set contents
Selection
Default
Setting the value of start torque to be indicated. Set the value to be as follows:
Upper limit torque
≧
cut torque
≧
lower limit torque
≧
start torque.
0.0
~
999.0(N
・
m)
3.0N
・
m
SWITCH TRQ
Set contents
Selection
Default
Set the torque to switch from motor mid-speed to motor high speed.
0.0
~
999.0(N
・
m)
3.0N
・
m
MIN TRQ
Set contents
Selection
Default
Setting the lower limit of torque. Set the value to be as follows:
Upper limit torque
≧
cut torque
≧
lower limit torque
≧
start torque.
0.0
~
999.0(N
・
m)
3.0N
・
m
CUT TRQ
Set contents
Selection
Default
Setting cut torque.
Set the value to be as follows: Upper limit torque
≧
cut torque
≧
lower limit
torque
≧
start torque.
0.0
~
999.0(N
・
m)
3.0N
・
m
MAX TRQ
Set contents
Selection
Default
Setting the upper limit torque. Set the value to be as follows:
Upper limit torque
≧
cut torque
≧
lower limit torque
≧
start torque.
0.0
~
999.0(N
・
m)
3.0N
・
m
FREERUNNING ANG MIN
Set contents
Selection
Default
Setting the lower limit of free-running angle Set the value to be as follows:
Upper limit of free-running angle
≧
lower limit of free-running angle.
0
~
30000
(
°
)
0
FREERUNNING ANG MAX
Set contents
Selection
Default
Setting the upper limit of free-running angle. Set the value to be as follows:
Upper limit of free-running angle
≧
lower limit of free-running angle.
0
~
30000
(
°
)
30000
FINAL ANG MIN
Set contents
Selection
Default
Setting the lower limit of final angle. Set the value to be as follows:
Upper limit of final angle
≧
lower limit of final angle.
0
~
9999
(
°
)
0
Содержание WU-1