
76-QD7913EN-00Y00-03.doc
19
7. Setting Items
7.1. Setting of tool 1
– 4
7.1.1. All work common setting items
Q’TY CONTROL
Set contents
Selection
Default
Setting ON/OFF of Q’TY CONTROL.
OFF
ON
OFF
START CONDITON
Set contents
Selection
Default
Selecting the start condition of Q’TY CONTROL.
※
If the setting is changed, remove and insert the battery pack of the tool.
WORK S
FASTN
WORK S
WAITING
Set contents
Selection
Default
Selecting the operation after completion of the work.
STOP
RUN
STOP
AUTO CLEAR
Set contents
Selection
Default
Setting AUTO CLEAR.
ON: When the remaining quantity becomes zero, it is cleared.
*This setting is valid only when the start condition is FASTN.
OFF
:
Even when the remaining quantity becomes zero, it is not cleared.
When PASS, RESET signal, or WORK S signal is entered, the remaining
quantity is cleared.
OFF
ON
OFF
END CONDITION
Set contents
Selection
Default
Selecting END CONDITION of Q’TY CONTROL.
END LS
NUNBER
END LS
TOOL BUZZER
Set contents
Selection
Default
Setting ON/OFF of tool buzzer at tightening judgement.
OFF
ON
ON
TOOL LAMP
Set contents
Selection
Default
Setting ON/OFF of tool lamp at tightening judgement.
OFF
ON
ON
Содержание WU-1
Страница 36: ...76 QD7913EN 00Y00 03 doc 36 12 External View ...