background image

 

 IM 61A YHC1-E-A  

3rd Edition: May 2008  

Page 6 of 34 

Navigating Menus on the YHC display

 

 
Several methods of navigating through the YHC menus are available to the user for maximum convenience 
and utility.   
 

1.

 

Soft keys

:  Use 

Up

 and 

Down

 Soft Keys to move cursor arrow to the desired menu option.  Then use  

the 

Select

 soft key to accept the indicated choice.  Soft key navigating tools are found throughout 

the YHC Main displays and HART communication displays. 

 

2.

 

Side keys

:  

Up

Down

 and 

Select

 keys are also provided on the left hand side of the YHC.  These 

keys are thumb operated and provide a convenient alternative to the Soft Key navigation buttons.  
Side key functionality is not always available in the HART communication displays. 

 

3.

 

Multi-page lists

: Multi-page lists have a      and/or      symbol along the right hand side of the 

display indicating the existence of information on the previous or next page(s).  Several pages of 
information may need to be viewed when reviewing lists of installed DOFs, stored configuration 
files or finding a specific device in Offline Mode to create a configuration for. While in these list 
areas, pressing the SHIFT key (    ) changes soft key definitions 

Select

 and 

Back

 to 

PgUp

 and 

PgDn

, respectively.

 

 To quickly advance to the next page of a list, press    and then the 

PgDn

 soft 

key. To retreat to the prior page, press 

  

 and then 

PgUp

.  

PgUp

 and 

PgDn

 soft keys remain active 

until the 

Up

 or 

Down

 soft key is used or until 

  

 is pressed again.   

 

4.

 

Numbered HART menus

:  All HART displays have numbered menu lines when needed.  This 

gives fast access directly to the desired menu line.  YHC displays also have numbered menus with 
the exception of multi-page list screens. 

 

5.

 

HART menu HOME key

:  To quickly retreat from any location in the HART menu to the initial 

HART menu screen for a device, press the 

  ,        

key sequence.  This will return the display to the 

initial HART screen.  The Home function will be disallowed if a critical HART task is in process. 

 

6.

 

Left / Right Arrow keys

:  Emulate 

Back

 and 

Select 

soft keys, respectively 

 
 
 

Turning on the YHC 

 

Use the dedicated 

ON/OFF

 key to power up the YHC.  A brief diagnostic runs while the Yokogawa logo, 

YHC model number, and YHC firmware version is displayed.  A message is displayed indicating the YHC is 
scanning for a HART device at address zero.  The following scenarios are possible. 
 
 

1.

 

If the YHC is connected to a HART device with address = 0 
(and there is sufficient loop resistance), the YHC immediately 
establishes HART communication with the device.  A display 
similar to the example at right appears.  The numbered menus 
and Soft Keys are then used to commission, re-configure, or 
maintain the connected device.  

 
 

 
 
 
 

Online    

           # 

 

 

 

EJX : PT-1012D 
 1  Device setup 
 2  Pres: 0.01 inH2O 
 3  AO: 4.001 mA 
 4  LRV: 0.00 inH2O 
 5  URV: 250.00 inH2O 

 

 

 
Up       Down       Select      Back

 

Содержание YHC 4150 Series

Страница 1: ...IM 61A YHC1 E A 3rd Edition May 2008 Users Manual YHC 4150X HART Communicator Model YHC 4150X Series HART Communicator...

Страница 2: ...Representatives and their contact information visit our web site at www yokogawa com HART is a registered trademark of the HART Communication Foundation Important information on the product is contai...

Страница 3: ...2 Applications 8 3 Lockouts Lockout PV Prompt setting View Lockout Details 8 Lockout Code 9 Disable Lockout 9 Changing Lockout Code 9 4 Clock Timers 9 1 Clock Edit 9 2 Backlight off timer 10 3 Off Tim...

Страница 4: ...Functions 21 DOF Memory Maintenance 22 Documenting HART Configurations with Yokogawa DMS Software 23 YHC 4150X Device Specific Generic HART Communication 23 Using Generic HART Communications 23 Updati...

Страница 5: ...ctions DISPLAY OVERVIEW The display of the YHC is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The display provides three types of informat...

Страница 6: ...to facilitate data entry Soft key functions change depending on the operating mode Soft key definitions are displayed at the bottom of the LCD just above their respective gray soft keys The left hand...

Страница 7: ...d user preferences at any time and in any operating mode Pressing and holding this key cycles through all available contrast settings After adjusting Display Contrast wait at least five 5 seconds befo...

Страница 8: ...ns of these keys change depending on the operating mode of the YHC Present definitions are displayed at the bottom of the YHC display Whenever possible the two Soft Keys on left are used for navigatio...

Страница 9: ...optional AC adapter P N Z9B000007 the battery circuit is bypassed and a wall plug icon replaces the battery icon on the display header For AC power use the AC adapter is connected to the Communicatio...

Страница 10: ...PgDn soft key To retreat to the prior page press and then PgUp PgUp and PgDn soft keys remain active until the Up or Down soft key is used or until is pressed again 4 Numbered HART menus All HART disp...

Страница 11: ...changes to Device 0 Online 2 2 Select Online Setup if properly connected HART device is setup for Multidrop loop or Burst Mode operation device address 0 The YHC will respond with a statement and the...

Страница 12: ...nline HART device configurations create offline HART device configurations update the installed DOFs list HART device profiles or to update the YHC s operating firmware For example locking out the Con...

Страница 13: ...t and Next Soft Keys to input a lockout code value Alternatively you may use the green keys for Increment and Decrement functions When you are satisfied with the lockout code value press Store IMPORTA...

Страница 14: ...sponding free memory space and number of HART configurations saved with corresponding free memory space 2 Battery shows present battery setting and optimizes the battery life indicator for the battery...

Страница 15: ...found the YHC automatically asks for direction select Multi soft key to start a multi drop poll from address 1 15 or select Retry soft key to try to find address 0 again for more details see the HART...

Страница 16: ...s Do not mix alkaline batteries with each other or with other battery types Battery replacement is recommended when the Replace Batteries notice is posted on the display however the YHC will function...

Страница 17: ...onnection to the YHC s Dongle connector while in a hazardous area Use the connector Dongle only in non hazardous areas 2 HART Jacks Lead Set All YHC models are equipped with a standard size banana jac...

Страница 18: ...nt manufacturers DO NOT replace batteries while in explosive or hazardous atmospheres DO NOT use any battery type other than those listed on the Intrinsic Safe Control Document found in the Appendix o...

Страница 19: ...Three HART command types are used by the YHC to communicate with HART field devices First Universal Commands are primarily used to identify a field device by its model number and tag number and to rea...

Страница 20: ...blish HART communications this is the factory default Auto poll function When a device with address zero is found the YHC provides feedback to the user and starts the initial HART display for the conn...

Страница 21: ...he loop will be displayed on the YHC s screen The address of interest can be selected from the list to launch HART communication with that device This Digital Poll is for one power cycle only and can...

Страница 22: ...ices one at a time Use the soft key controls to move through the list Pressing the key changes soft key definitions Down and Up to PgUp and PgDn To quickly advance to the next page of a list press the...

Страница 23: ...ly the edited parameters MVar Primary Cfg for multivariable devices Primary Variable configuration MVar Sub Config for multivariable devices Sub configuration secondary tertiary fourth etc variables 3...

Страница 24: ...sult the device manual for menu structure details YHC features two unique online features for added convenience to the user 1 Live HART connection monitor YHC display lets you know from the Main navig...

Страница 25: ...DOFs link at http fibu yokogawa usa com yhc4150 html Sort the list by clicking on any column header For download instructions see the DOF Firmware Download Site section of this manual 2 The connected...

Страница 26: ...ory is free This indicates fragmentation To optimize DOF flash memory it is necessary to delete all DOFs and then reload them all in one session Connect the YHC to a host PC that has DPC Manager insta...

Страница 27: ...using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim operations for analog...

Страница 28: ...ble by subscription A list of currently available DOF s for HART device communication can be viewed at the http fibu yokogawa usa com yhc4150 html Click on the Available DOFs link and sort the list by...

Страница 29: ...port C Dongle and RS 232 Cable are connected to the YHC and the unit is turned on Note HART communication cannot occur while communicating using the RS 232 connection D The AC power adapter is connect...

Страница 30: ...individual files for downloading from a list of downloadable files including DPC Manager Utility YHC Firmware and DOF s by locating the file name of interest with the PC mouse and clicking on the cor...

Страница 31: ...Advance Settings To report any difficulties with downloading operations please contact a Yokogawa Office Representative or Agent 8 Use the browser button to navigate to the location of the DOF files...

Страница 32: ...ly marked on the package being shipped back the unit will be returned at the shipper s expense This number will be provided by the Yokogawa Repair Department when you call fax or e mail your informati...

Страница 33: ...A alkaline batteries without backlight 27 hours using AA alkaline batteries with backlight TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C Operating 23 F to 122 F 5 C to 50 C CONNECTIONS...

Страница 34: ...YHC ACCESSORIES LIST Z4150 7G Protective green boot provides degree of protection against drop related damage slip on A900529 00014 HART Test Lead Kit included w YHC standard banana plugs mini grabbe...

Страница 35: ...IM 61A YHC1 E A 3rd Edition May 2008 Page 31 of 34 Intrinsic Safety Control Drawing...

Страница 36: ...Agency UL International DEMKO A S Testing Certification 0539 P O Box 514 Lyskaer 8 DK 2730 Herlev Denmark This Declaration is based on Compliance with the following Standards Regarding Hazardous Envi...

Страница 37: ...og Trim Menu 4mA Analog Trim 20mA Analog Trim DAC Trim Loop Test Scaled DAC Trim Revisions HART Revision Device Revision Software Revision Final Assbly Number Basic Info Tag Date Descriptor Message Pr...

Страница 38: ...Isolator Material Flange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const Mats Device ID Polling Address Request...

Отзывы: