3-15
3. INSTALLATION
(4) Connecting to Pipe
Please pass bolts from pipe line side, not flow tube
side, and tighten the bolts according to Torque Values
in Table 3.3.9.
CAUTION
• Please be sure to tighten the bolts following
prescribed torque values. Please tighten the
flange bolts diagonally with the same torque
values, step by step up to the prescribed torque
value.
• Please completely cover the brackets and liners
with mortar.
Figure 3.3.7
Mounting Flow Tube
Table 3.3.13
Tightening Torgue Values for Metal Piping
* Please use rubber gasket or the gasket which has equal elasticity.
T030313.EPS
JIS G3451 F12/JIS7.5K
JIS10K
Flange
Rating
SIze:
mm (inch)
ANSI150
N-m
N-m
N-m
kgf-cm
kgf-cm
kgf-cm
in-Ibf
in-Ibf
in-Ibf
500
(20)
600
(24)
700 (28)
800
(32)
900
(36)
1000
(40)
1100
(44)
1200
(48)
1350
(54)
1500
(60)
1600
(64)
1800
(72)
2000
(80)
2200
(88)
2400
(96)
2600 (104)
121
to 150
116
to 145
173
to 215
180
to 224
102
to 127
231
to 288
298
to 372
301
to 376
432
to 539
463
to 578
468
to 585
485
to 605
615
to 768
686
to 858
759
to 948
1006
to 1257
1234
to 1530
1183
to 1479
1765
to 2193
1836
to 2285
1040
to 1295
2356
to 2938
3040
to 3794
3070
to 3835
4406
to 5498
4723
to 5896
4774
to 5967
4947
to 6171
6273
to 7834
6997
to 8752
7742
to 9670
10261
to 12821
1071
to 1327
1027
to 1283
1531
to 1903
1593
to 1982
903
to 1124
2044
to 2549
2637
to 3292
2664
to 3327
3823
to 4770
4097
to 5115
4142
to 5177
4292
to 5354
5442
to 6796
6071
to 7593
6717
to 8389
8903
to 11124
63
to 79
78
to 97
104
to 130
115
to 144
175
to 182
204
to 254
—
—
—
—
—
—
—
—
—
—
643
to 806
796
to 989
1061
to 1326
1173
to 1469
1785
to 1856
2081
to 2591
—
—
—
—
—
—
—
—
—
—
558
to 699
690
to 858
920
to 1150
1018
to 1274
1549
to 1611
1805
to 2248
—
—
—
—
—
—
—
—
—
—
59 to 73
67 to 84
—
—
—
—
—
—
—
—
—
—
—
—
—
—
602 to 745
683 to 857
—
—
—
—
—
—
—
—
—
—
—
—
—
—
522 to 646
593 to 743
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.3.6
Mounting Procedure for Sani-
tary Type
The sanitary type is mounted using IDF clamps.
(1) Mounting Direction
Please mount the Magnetic Flow Tube matching the
flow direction of the fluid to be measured with the
direction of the arrow mark on the flow tube.
IMPORTANT
If it is impossible to macth the direction, please
never remodel to change direction of the termi-
nal box. In case the measuring fluid flows
against the arrow direction, please refer to the
section “Reversing Flow Direction” in the Instruc-
tion Manual of AM11 Magnetic Converter.
(2) Welding of Mating Ferrule to Piping
IMPORTANT
Weld the attached ferrules to the piping. Please
pay attention to the welding condition to avoid
deforming piping or making the stagnant portion
of the fluid; joint preparation, level difference in
butt joint, welding current.
(3) Mounting Gasket
Mount the attached gasket so it fits into the groove on
the ferrule.
(4) Positioning Flow Tube
Position the flow tube between the mating ferrule.
(5) Tightening Clamp
Mount the clamp so they cover the flow tube and
mating ferrule tapered part.
Clamp
Ferrule
Welding
Pipe
F030308.EPS
Figure 3.3.8
Mounting Procedure