3.2 Functions 

 

Traffic Generation Function 

Item Specifications 

Constant rate: %, µs, ns, bit (48 bits minimum), frame/s, or bps 

Rate 

Burst (interval setting: 1 µs to 1 s) 

Transmission 
mode 

Transmission 
mode 

Continuous, single shot (specify the number of transmission 
frames), time designation (in unit of s) 

Defined no. of 
frames 

128 frames/port max.    (one frame is used for the insert frame) 

Frame length 

48–9999 bytes (fixed frame length) 

Defined 
frames 

IPv4, IPv6, IPX, UDP, TCP, IGMP, ICMP, ICMPv6, ARP, PAUSE
custom (with MAC), custom (without MAC) 
tag (VLAN tag, MPLS, EoMPLS) 

Increment 

MAC address increment can be set 

Payload 
setting 

Set in the range of 00 to FFh.    Set the size to Byte, Word, or 
LongWord. 

Transmitted 
data (fixed) 

Errors 

CRC error, symbol error, IP header checksum error, TCP 
checksum error, UDP checksum error, ICMP checksum error, 
ICMPv6 checksum error, and IGMP checksum error 

No. of variable 
fields 

Up to 4 fields can be varied simultaneously 

Variable size 

128 bit width (can be divided in to 4 fields in unit of 32 bits) 

Variable field 
offset 

0 to 9990 bytes 

Variable 
method 

Increment, random, or table reference (max. no. of ref. tables: 
1024) 

Transmitted 
data (variable) 

Frame length 

Range: 64 to 9999 bytes (set increment, decrement, or random)

Manual 

One frame can be sent manually. 

Insert frame 
function 

Periodic 

Sends insert frames periodically.    Period setting: 1 ms to 600 s 
(1 ms resolution) 

Manual 

Generate link up or link down through manual operation 

Transmit 

Link up/down 
control 
function 

Periodic 

Repetitively generate link up and link down Min. period: 10 s.   
Max. period: 3600 s.    Step: 1 s 

MAC filter 

Receive frames only from a specified destination MAC address, 
source MAC address, or unicast frames 

VLAN filter 

VLANID, TPID, and Priority can be set 

Filter 

Pattern filter 

Two filters each consisting of 6-byte comparison and mask 
patterns and offset can be set.    AND or OR logic, pass, or 
reject on the two filters can be set. 

Normal 

No. of frames, no. of bytes, rate (%), rate (frame/s), rate 
(byte/s), rate (bps), no. of insert frames, and no. of reply frames
No. of error frames, no. of CRC error frames, no. of undersize 
frames, no. of oversize frames, and no. of symbol error frames 

Transmit 
statistics 
display 

Error 

Error frames (frame/s), CRC errors (frame/s), undersize 
(frame/s), oversize (frame/s), and symbol errors (frame/s) 

Normal 

No. of frames, no. of bytes, rate (%), rate (frame/s), rate 
(byte/s), rate (bps), no. of pause frames, and no. of collisions 
detected 
No. of error frames, no. of CRC error frames, no. of undersize 
frames, no. of oversize frames, no. of alignment error frames, 
no. of symbol error frames, and no. of late collisions detected 

Receive 
statistics 
display 

Error 

Error frames (frame/s), CRC errors (frame/s), undersize 
(frame/s), oversize (frame/s), alignment error (frame/s), and 
symbol errors (frame/s) 

Statistics 
mode 

For each flow (frame pattern comparison) and for each frame 
length 

Statistics 
channel 

8 channels 

Statistical 
items 

Total (frame), total (byte), rate (frame/s), rate (%), and rate (bps)

Receive 

QoS 
statistics 
display 

QoS statistical 
filter 

Two filters each consisting of 32-bit comparison and mask 
patterns and offset can be set. 
Frame length can be specified. 

Содержание 731010

Страница 1: ...User s Manual Yokogawa Electric Corporation Model 731010 AE5523 1000BASE T Unit IM 731010 01E 1st Edition ...

Страница 2: ...ram TTPro Control WindowE you must download it from the Web page located at the URL below and install it in the AE5511 and the controller PC http www yokogawa com tm AE5511 If you do not have the AE5511 manual for the Windows version download it also from the Web page located at the URL above Notes The contents of this manual are subject to change without prior notice as a result of continuing imp...

Страница 3: ... 1000BASE T Unit No Instrument No The instrument number is inscribed on the name plate at the bottom of the AE5523 unit When contacting the dealer from which you purchased the instrument please give them the instrument number Standard Accessories The standard accessories below are supplied with the instrument Item Manual No Quantity Notes AE5523 1000BASE T Unit User s Manual IM731010 01E 1 This ma...

Страница 4: ...ears on dangerous locations on the instrument which require special instructions for proper handling or use The same symbol appears in the corresponding place in the manual to identify those instructions Hazard radiation of laser apparatus Make sure to comply with the precautions below Not complying might result in injury or death WARNING Do Not Operate in an Explosive Atmosphere Do not operate th...

Страница 5: ...ify those instructions In the manual the symbol is used in conjunction with the word WARNING or CAUTION Calls attention to actions or conditions that could cause serious or fatal injury to the user and precautions that can be taken to prevent such occurrences WARNING Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user s data and p...

Страница 6: ...ional Overview and Names of Parts 1 1 Functional Overview 1 1 1 2 Front Panel 1 2 1 3 PoE Monitor Connector 1 3 Chapter 2 Operation 2 1 Installing the Unit 2 1 2 2 Installing the Interface Module 2 2 Chapter 3 Specifications 3 1 Interface 3 1 3 2 Functions 3 2 3 3 General Specifications 3 4 3 4 External Dimensions 3 5 IM 731010 01E v ...

Страница 7: ...eclaration Line power detection function Evaluation of electrical characteristics using a PoE monitor connector Connection of an external electric load device required Basic measurement functions Traffic generation function Latency measurement function Bit error rate measurement function Multi user function up to 8 users can connect simultaneously Capture function equipped with 1 MB capture memory...

Страница 8: ...ine link up status TX Illuminates when transmitting data RX Illuminates when receiving data Blinks during a self test RJ 45 connector A connector for 10 100 1000BASE T PoE monitor connector A connector for monitoring the PoE line power status See section 1 3 LED for SFP LINK Illuminates during line link up status TX Illuminates when transmitting data RX Illuminates when receiving data Blinks durin...

Страница 9: ...output G1 to G12 Ground 13 1 26 14 CAUTION Turn OFF the power when connecting disconnecting the cable Check that the AE5511 TrafficTesterPro is turned OFF when connecting disconnecting the PoE monitor cable Connecting Disconnecting the cable with the power turned ON may damage the AE5523 electrically Do not short the terminals If a PoE device is connected and the PoE setting is enabled voltage is ...

Страница 10: ...de of the AE5511 and insert it slowly toward the back of the AE5511 3 Press the panel section of the unit with your thumbs until the connectors on the unit and AE5511 engage 4 Fasten the two attachment screws of the unit to fix the unit in place Removing the Unit Pull the lever 1 Check that the main power of the AE5511 is turned OFF 2 Loosen the two attachment screws of the unit 3 Pull the unit le...

Страница 11: ...h the cable connected Doing so may cause malfunction Align the SFP module with the SFP module guide of the unit and insert the module slowly into the unit Press the module in firmly until the connectors engage Removing the SFP Module Pull out the lever at the front top section of SFP module and pull the lever toward you The connectors disengage and the SFP module comes out from the unit Note The S...

Страница 12: ...ion operation Blinks during a self test LINK green Illuminates during line link up status Blinks during a self test RJ 45 connector LED PoE green Illuminates when PoE is detected Blinks during a self test Standard 1000BASE SX 1000BASE LX Complies with IEEE802 3z Complies with IEEE802 3z Number of ports 1 port Link speed 1000 Mbps Duplex Fixed to full duplex Auto negotiation ON OFF setting flow con...

Страница 13: ...mit Link up down control function Periodic Repetitively generate link up and link down Min period 10 s Max period 3600 s Step 1 s MAC filter Receive frames only from a specified destination MAC address source MAC address or unicast frames VLAN filter VLANID TPID and Priority can be set Filter Pattern filter Two filters each consisting of 6 byte comparison and mask patterns and offset can be set AN...

Страница 14: ...mask pattern 6 bytes 2 Offset 0 to 58 bytes Capture only normal frames error frames layer 1 state change or insert frames Normal frame pattern Comparison pattern 6 bytes 2 mask pattern 6 bytes 2 Offset 0 to 58 bytes Completion of the insert frame transmission Error frames CRC error undersize oversize symbol error sequence error bit error all error frame link up and link down Trigger function Trigg...

Страница 15: ...ions Voltage 5 VDC or 3 3 VDC Power supply Power consumption 47 W or less Dimensions H40 W200 D260 mm projections excluded Dimensions and weight Weight Approx 1 kg Temperature 5 to 40 C Operating environment Humidity 35 to 85 3 4 IM 731010 01E ...

Страница 16: ...3 4 External Dimensions Unit mm Tolerance 3 287 7 200 13 7 32 40 260 3 3 Specifications IM 731010 01E 3 5 ...

Отзывы: