background image

3.2  Functions 

IM 731010-01E 

3-3 

33

S

p

ecificatio

n

s

 

 

Latency Measurement Function 

Item Specifications 

IFG 

Measures the max., min., and average IFG (Inter Frame Gap) 
(unit: µs) 

Packet latency 

Measures the max., min., and average packet delay (unit: µs) 

Measurement item 

Packet delay for 
each QoS 

Measures the packet delay for each flow (8 channels) 

 

Bit Error Rate Measurement Function 

Item Specifications 

Constant rate: %, 

µ

s, ns, bit (48 bits minimum), frame/s, or bps 

Rate 

Burst (interval setting: 1 

µ

s to 1 s) 

Transmission 
mode 

Transmission 
mode 

Continuous, single shot (specify the number of transmission 
frames), time designation (in unit of s) 

Defined no. Of 
frames 

1 frame/port (64 to 9999 bytes) 

Frame length 

64–9999 bytes (fixed frame length) 

Transmitted 
data (fixed) 

Test pattern 
(payload) 

PN15 

Variable 
Method 

Increment, decrement, and random 

Transmit 

Variable 
frame length 

Frame length 

64 to 9999 bytes 

Receive 

Displayed statistical items 

Bit error rate, bit error frame, bit error count. sync loss, checked 
byte, bit error (bps), bit error frame (frame/s), sync loss/s, 
checked byte/s, bit error insert, and bit error insert frame 

 

Capture Function 

Item Specifications 

 

Capture size 

1 MB per port 

Frame slice function

Select from four types: 64, 256, 2048, or 9999 bytes 

Filter function 

•  Pattern filter 

Comparison pattern: 6 bytes × 2, mask pattern: 6 bytes × 2 
Offset: 0 to 58 bytes 

•  Capture only normal frames, error frames, layer 1 state 

change, or insert frames 

• Normal 

frame 

pattern 

Comparison pattern: 6 bytes × 2, mask pattern: 6 bytes × 2 
Offset: 0 to 58 bytes 

•  Completion of the insert frame transmission 
• Error 

frames 

CRC error, undersize, oversize, symbol error, sequence error, 
bit error, all error frame, link up, and link down 

Trigger function 

Trigger position (select from three types) 

Top, center, or end 

Displayed items 

Frame No., time stamp, frame status, frame length, destination 
MAC address, source MAC address, payload data (hex display) 

Capture function 

File type 

AE5511 format, Etherreal (tcpdump) format, and CSV format 

 

Other Functions 

Item Specifications 

 

PD emulation 

Sequence emulation conforming to IEEE802.3af 

Class declaration 

Declare default class or arbitrary class 

PoE measurement 
function 

Line power detection  Detects the ON/OFF status of power feeding 

Sequence check 
function 

Types of errors 
detected 

Packet loss, max. burst packet loss, reordered packets, and 
duplicate packets 

IPv4 

ARP reply, Ping reply, and MAC address auto learn 

Emulation function 

IPv6 

NDP address resolution function, PING6 reply function, and auto 
address generation function 

Alarm items 

Packet error, reception rate error, packet delay error, IFG error, 
and layer 1 state change 

Alarm log function 

No. of recorded logs

Up to 1000 events (log recorded at 1-s intervals min.) 

Transmit clock 
variable function 

 

Range: ±100 ppm.    Resolution: 1 ppm.    Accuracy: 5 ppm ± 1 
digits 

Содержание 731010

Страница 1: ...User s Manual Yokogawa Electric Corporation Model 731010 AE5523 1000BASE T Unit IM 731010 01E 1st Edition ...

Страница 2: ...ram TTPro Control WindowE you must download it from the Web page located at the URL below and install it in the AE5511 and the controller PC http www yokogawa com tm AE5511 If you do not have the AE5511 manual for the Windows version download it also from the Web page located at the URL above Notes The contents of this manual are subject to change without prior notice as a result of continuing imp...

Страница 3: ... 1000BASE T Unit No Instrument No The instrument number is inscribed on the name plate at the bottom of the AE5523 unit When contacting the dealer from which you purchased the instrument please give them the instrument number Standard Accessories The standard accessories below are supplied with the instrument Item Manual No Quantity Notes AE5523 1000BASE T Unit User s Manual IM731010 01E 1 This ma...

Страница 4: ...ears on dangerous locations on the instrument which require special instructions for proper handling or use The same symbol appears in the corresponding place in the manual to identify those instructions Hazard radiation of laser apparatus Make sure to comply with the precautions below Not complying might result in injury or death WARNING Do Not Operate in an Explosive Atmosphere Do not operate th...

Страница 5: ...ify those instructions In the manual the symbol is used in conjunction with the word WARNING or CAUTION Calls attention to actions or conditions that could cause serious or fatal injury to the user and precautions that can be taken to prevent such occurrences WARNING Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user s data and p...

Страница 6: ...ional Overview and Names of Parts 1 1 Functional Overview 1 1 1 2 Front Panel 1 2 1 3 PoE Monitor Connector 1 3 Chapter 2 Operation 2 1 Installing the Unit 2 1 2 2 Installing the Interface Module 2 2 Chapter 3 Specifications 3 1 Interface 3 1 3 2 Functions 3 2 3 3 General Specifications 3 4 3 4 External Dimensions 3 5 IM 731010 01E v ...

Страница 7: ...eclaration Line power detection function Evaluation of electrical characteristics using a PoE monitor connector Connection of an external electric load device required Basic measurement functions Traffic generation function Latency measurement function Bit error rate measurement function Multi user function up to 8 users can connect simultaneously Capture function equipped with 1 MB capture memory...

Страница 8: ...ine link up status TX Illuminates when transmitting data RX Illuminates when receiving data Blinks during a self test RJ 45 connector A connector for 10 100 1000BASE T PoE monitor connector A connector for monitoring the PoE line power status See section 1 3 LED for SFP LINK Illuminates during line link up status TX Illuminates when transmitting data RX Illuminates when receiving data Blinks durin...

Страница 9: ...output G1 to G12 Ground 13 1 26 14 CAUTION Turn OFF the power when connecting disconnecting the cable Check that the AE5511 TrafficTesterPro is turned OFF when connecting disconnecting the PoE monitor cable Connecting Disconnecting the cable with the power turned ON may damage the AE5523 electrically Do not short the terminals If a PoE device is connected and the PoE setting is enabled voltage is ...

Страница 10: ...de of the AE5511 and insert it slowly toward the back of the AE5511 3 Press the panel section of the unit with your thumbs until the connectors on the unit and AE5511 engage 4 Fasten the two attachment screws of the unit to fix the unit in place Removing the Unit Pull the lever 1 Check that the main power of the AE5511 is turned OFF 2 Loosen the two attachment screws of the unit 3 Pull the unit le...

Страница 11: ...h the cable connected Doing so may cause malfunction Align the SFP module with the SFP module guide of the unit and insert the module slowly into the unit Press the module in firmly until the connectors engage Removing the SFP Module Pull out the lever at the front top section of SFP module and pull the lever toward you The connectors disengage and the SFP module comes out from the unit Note The S...

Страница 12: ...ion operation Blinks during a self test LINK green Illuminates during line link up status Blinks during a self test RJ 45 connector LED PoE green Illuminates when PoE is detected Blinks during a self test Standard 1000BASE SX 1000BASE LX Complies with IEEE802 3z Complies with IEEE802 3z Number of ports 1 port Link speed 1000 Mbps Duplex Fixed to full duplex Auto negotiation ON OFF setting flow con...

Страница 13: ...mit Link up down control function Periodic Repetitively generate link up and link down Min period 10 s Max period 3600 s Step 1 s MAC filter Receive frames only from a specified destination MAC address source MAC address or unicast frames VLAN filter VLANID TPID and Priority can be set Filter Pattern filter Two filters each consisting of 6 byte comparison and mask patterns and offset can be set AN...

Страница 14: ...mask pattern 6 bytes 2 Offset 0 to 58 bytes Capture only normal frames error frames layer 1 state change or insert frames Normal frame pattern Comparison pattern 6 bytes 2 mask pattern 6 bytes 2 Offset 0 to 58 bytes Completion of the insert frame transmission Error frames CRC error undersize oversize symbol error sequence error bit error all error frame link up and link down Trigger function Trigg...

Страница 15: ...ions Voltage 5 VDC or 3 3 VDC Power supply Power consumption 47 W or less Dimensions H40 W200 D260 mm projections excluded Dimensions and weight Weight Approx 1 kg Temperature 5 to 40 C Operating environment Humidity 35 to 85 3 4 IM 731010 01E ...

Страница 16: ...3 4 External Dimensions Unit mm Tolerance 3 287 7 200 13 7 32 40 260 3 3 Specifications IM 731010 01E 3 5 ...

Отзывы: