YOKOGAWA 701949 Скачать руководство пользователя страница 2

Product Registration

Thank you for purchasing YOKOGAWA products.

YOKOGAWA provides registered users with a variety of information and 
services.  Please allow us to serve you best by completing the product 
registration form accessible from our website.

https://tmi.yokogawa.com/

Содержание 701949

Страница 1: ...Userʼs Manual IM 701949 01EN 1st Edition Model 701949 Miniature Passive Probe ...

Страница 2: ... purchasing YOKOGAWA products YOKOGAWA provides registered users with a variety of information and services Please allow us to serve you best by completing the product registration form accessible from our website https tmi yokogawa com ...

Страница 3: ...ption Model 701949 Miniature Passive Probe User s Manual IM 701949 01EN This manual Explains usage specifications and the handling precautions of the 701949 Model 701949 ミニチュアパッシブプローブ ユーザーズマニュアル IM 701949 01JA The Japanese version of the above manual 701949 Miniature Passive Probe IM 701949 92Z1 Document for China The EN JA and Z1 in the manual numbers are the language codes Contact information of...

Страница 4: ...wever should you have any questions or find any errors please contact your nearest YOKOGAWA dealer Copying or reproducing all or any part of the contents of this manual without the permission of YOKOGAWA is strictly prohibited Trademarks Adobe and Acrobat are either registered trademarks or trademarks of Adobe Systems incorporated In this manual the and TM symbols do not accompany their respective...

Страница 5: ...information that is important for the proper operation of the instrument French Une manipulation ou une utilisation incorrectes risquent de blesser l utilisateur ou d endommager l instrument Ce symbole apparaît sur l instrument pour indiquer à l utilisateur qu il doit se reporter au manuel de l utilisateur afin d y lire les instructions spécifiques correspondantes Ce même symbole apparaît à la sec...

Страница 6: ... oscilloscope manual to thoroughly familiarize yourself with its specifications and handling The following symbols are used on this instrument Handle with care Refer to the user s manual or service manual This symbol appears on dangerous locations on the instrument which require special instructions for proper handling or use The same symbol appears in the corresponding place in the manual to iden...

Страница 7: ... to the device under measurement Do not operate in wet or damp conditions To prevent electric shock do not operate the probe in wet or damp conditions Avoid exposed circuitry To prevent electric shock remove metal and jewelry such as watches and rings Do not touch exposed connections or components when power is present on the device Do not operate in explosive atmosphere To prevent injury or fire ...

Страница 8: ...e faites pas fonctionner la sonde dans des conditions mouillées ou humides Évitez les circuits exposés Pour éviter un choc électrique retirez le métal et les bijoux tels que les montres et les bagues Ne touchez pas les connexions ou composants exposés en présence de courant sur l appareil N opérez pas dans une atmosphère explosive Pour éviter les blessures et les risques d incendie n utilisez pas ...

Страница 9: ... types in the WEEE directive this product is classified as a Monitoring and Control instrumentation product Do not dispose in domestic household waste When disposing products in the EU contact your local Yokogawa Europe B V office Authorized Representative in the EEA Yokogawa Europe B V is the authorized representative of Yokogawa Test Measurement Corporation in the EEA for this Product To contact...

Страница 10: ...ist of Standard Accessories 2 Combinations and Dimensions of Accessories 3 3 How to use How to Connect to Oscilloscopes 4 Contact Tips and IC Caps 6 Connecting to Ground 7 Installing the Pincher Tip 7 How to Adjust the Probe Phase 8 4 Maintenance Cleaning 9 Changing the Contact Tips 9 5 Specifications Specifications 11 Input Voltage Derating by Frequency 13 Input Impedance Derating 13 Temperature ...

Страница 11: ...s with input impedances of 1 MΩ The probe is designed for user safety and ease of use suitable for measuring high density mounting boards By adopting a spring structure for the contact tip the stress applied on the device under measurement is minimized In addition by using various accessories such as IC caps you can easily contact the pins of fine pitch ICs ...

Страница 12: ...15 Cu sheets 2 x 2 cm x 2 sheets 6 IC cap 0 65 mm pitch blue 16 PCB adapter kit 7 IC cap 0 8 mm pitch gray 17 Marker tips 4 colors x 3 8 IC cap 1 0 mm pitch brown 18 Adjustment screwdriver 9 IC cap 1 27 mm pitch black 19 Two footer probe positioner 10 Insulation cap 20 Manuals 2 1 Attached to the probe main unit 2 See the table below Manual Title Manual No Description Model 701949 Miniature Passiv...

Страница 13: ...lade 15 Cu pads 2 x 2 cm x 2 sheets DEVICE UNDER TEST 2 Spring tip Ø0 5 mm 3 Rigid tip Ø0 5 mm 4 Pincher tip length 77 6 mm 6 0 65 mm pitch blue 7 0 8 mm pitch gray 8 1 0 mm pitch brown 9 1 27 mm pitch black 17 Marker tip 4 colors x 3 yellow red green blue 19 Two footer positioner 10 Insulation cap 20 Manuals 106 5 15 2 5 87 8 18 6 Ø15 0 Ø9 2 Probe tip Ø2 5 mm Probe cable Adjustment screw Contact ...

Страница 14: ...s electric shock or damage to the instruments When the oscilloscope s input coupling is AC a DC voltage is applied to the oscilloscope s input at the same electric potential as the probe s input Make sure not to exceed the oscilloscope s maximum input voltage This probe cannot be used to measure the voltage between two points floating from the ground potential Consider using a differential probe W...

Страница 15: ...sque le couplage d entrée de l oscilloscope est AC une tension DC est appliquée à l entrée de l oscilloscope au même potentiel électrique que l entrée de la sonde Assurez vous de ne pas dépasser la tension d entrée maximale de l oscilloscope La sonde ne peut être utilisée pour mesurer la tension entre deux points flottant du potentiel de terre Pensez à utiliser une sonde différentielle Lors de la ...

Страница 16: ...e accessories connect the probe to the device under measurement 4 Adjust the probe phase before use Note Accurate measurements may not be possible near objects with strong electromagnetic fields such as transformers large current circuits or wireless equipment Contact Tips and IC Caps Contact tips are available as a spring tip spring structure already attached to the probe body and a rigid tip sol...

Страница 17: ...e device under measurement Then connect it to the ground ground potential by soldering or by other means Good ground connection can be made using the included ground blade or ground spring Ground blade etc Cu sheet To Ground pin Device Probe main unit IC cap Installing the Pincher Tip To use the pincher tip first install it on the probe so that the pincher tip comes to the line indicated by the ar...

Страница 18: ...he input of the oscilloscope and connect the probe input to the oscilloscope signal output terminal for probe compensation adjustment CAL or COMP terminal 2 Operate the vertical and time scales on the oscilloscope and turn the phase adjustment screw with the included adjustment screwdriver to adjust the observed waveform to the correct waveform square wave Adjust the probe capacitance to match the...

Страница 19: ...nts abrasifs ni de solvants volatils tels que la benzine sur la sonde Use a soft cloth to clean the probe Changing the Contact Tips CAUTION When changing contact tips do not grip the housing or the white plastic insulator of the probe tip Doing so may damage the probe tip French ATTENTION Lors du changement des pointes de contact ne saisissez pas le boîtier ni l isolant en plastique blanc de la po...

Страница 20: ...e front of the probe tip grasp the contact tip firmly with a pair of pliers or the like and insert or remove it straight along the probe shaft Grip the contact tip with pliers Do not grip the housing or the white plastic insulator with pliers 4 Maintenance ...

Страница 21: ...vironment Temperature Humidity 40 C to 71 C no condensation Altitude 15000 m or less Compliant standards Safety standards EN61010 031 Measurement category O 6 400 Vrms 1250 V transient over voltage Measurement category II 6 300 Vrms Pollution degree 2 7 Environmental standards EN50581 Monitoring and control instruments 1 In combination with an oscilloscope with an input impedance of 1 MΩ 1 Input v...

Страница 22: ...er source Measurement category II CAT II CAT II applies to measurement of electrical equipment that is powered through a fixed installation such as a wall outlet wired to a distribution board and measurement on such wiring Measurement category III CAT III CAT III applies to measurement at the distribution level that is building wiring fixed installations Measurement category IV CAT IV CAT IV appli...

Страница 23: ...quence du signal d entrée augmente la tension d entrée maximale de la sonde diminue Frequency Hz Input Voltage Derating by Frequency Measurement Category O Sine Wave Typical 0 100 200 300 400 100 k 1 M 10 M 100 M 1 G Maximum Input Voltage Vrms V 6 V 500 M Input Impedance Derating CAUTION As the frequency of the input signal increases the input impedance of the probe decreases 5 Specifications ...

Страница 24: ...pedance Derating Typical 10 100 1k 10k 100k 1M 10M 100M 10 100 1 k 10 k 100 k 1 M 10 M 100 M 1 G Frequency Hz Input Impedance Ω Temperature vs Humidity Derating Derating by temperature vs humidity is applied 0 10 20 30 40 50 60 70 80 10 20 31 C 40 50 40 RH Humidity RH Temperature C Temperature vs Humidity Derating 30 5 Specifications ...

Отзывы: