YMGI: Your Modern Green Idea
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!
33
3. Once connected, secure the power and connection wires with a cord clamp. (see illustration of preceding page)
1.
Before starting work, check that power is not being supplied to the indoor unit and outdoor unit.
2.
Match the terminal block numbers and connection wire colors with those of the indoor unit side.
3.
Improper wiring can cause burning or damage to the electric components.
4.
Connect the wires firmly to the terminal block. Improperly securing the wiring can cause a fire.
5.
Always fasten the outside covering of the connection cord with cord clamps. (If the insulator is not clamped,
electric leakage may occur.)
6.
Always connect the ground wire.
Electric wiring between the indoor and outdoor units
Single-phase units (12~24k)
Electric wiring of indoor unit side
Remove the electric box cover from the electric box sub-assembly and then connect the wire.