These precautions are essential and must be strictly observed.
DO NOT
pull on the power cord or refrigeration lines.
Install them in a secured position. A line set plastic
cover is recommended.
DO NOT
install the unit in places where there is
exposure to flammable materials or gas leakage.
DO NOT
use wire or circuit breakers that do not meet
electrical safety standards. Several circuits cannot
be connected to one breaker.
DO NOT
wire or open the unit while it is running.
Make sure to shut off all circuits prior to inspecting or
servicing the unit.
DO NOT
install unit in a damp laundry room or near
flammable gas. All units must be protected by
certified electrical circuit breakers and in accordance
with all safety codes.
DO NOT
use the unit in cool or dry mode for
prolonged periods where humidity is higher than 80%.
SAFETY WARNINGS
IMPORTANT NOTES
READ THESE SAFETY WARNINGS COMPLETELY PRIOR TO ANY USE.
SAFETY CAUTIONS AND ALERTS
Installation, Operation, Maintenance, and Service shall follow professional standards and practices for
conventional cooling and heating equipment, under International, National, State, City or Local Codes, and follow
guidelines listed in all related manuals and associated product information provided directly from YMGI.
Failure to adhere to proper Installation, Operation, Maintenance, and Service could result in damage to
equipment, personal property, or physical injury, or even death.
Installation must be performed following the
YMGI Installation/Maintenance Manuals.
Installation must be performed by a certified
technical installer only.
DO NOT attempt to install
the unit by yourself trying to save money. Improper
or Incomplete Installation will void YMGI provided
warranty and could result in injury or death or
property damage due to fire, electrical shock, leaking,
collapsing. Shall consult the authorized YMGI
Distributor or Dealer for recommended Contractors/
Installers.
Install the unit onto a strong load bearing
structure
. The location must be capable of handling
the weight load of the unit to prevent the unit from
falling or causing injury.
Attach both the indoor and
outdoor units to the brackets that are fixed to the
right position securely.
Only use manufacturer specified and codes
allowed wires and conduits to connect to the
units so the stress is not applied to the sections.
Incomplete connecting and insecure fixing could
cause fire or damage.
Wiring must conform to national regulations
.
Failure to adhere to these standards could result in
personal injury or death or property damage due to
fire, electrical shock, falling units, or leaking.
Connect the power cord directly to a designated
and exclusive AC Power Circuit Breaker and or
Disconnect Switch.
The circuit must exceed
permissible currents and is free of insulation and
contact defects. Shall refrain from intermediate or
multiple connections to avoid fire or electric shock.
DO NOT supply power until all wiring and tubing
is checked completely.
Double check for gas leaks during or after
installation.
The refrigerant gas may cause harmful
substances when subjected to heat or fire.
Refrigerant leakage will cause unit not to generate
enough cooling or heating and even damage
compressors and other parts.
Shut off the main power prior to and during
installation to avoid electrical shock.
Make sure
that the electrical power is disconnected from the
unit by making a notice or put a sign at the power
switch panel, to keep other people from setting the
power back during installation.
Connect all wiring securely.
Any loose wire or other
bad contact may cause an electrical arc, overheating,
or fire hazard. Make sure that the unit is grounded
following YMGI Instructions and all NEC,
International, State, City, and Local Codes. Electrical
cover shall be securely attached to the indoor and
outdoor unit service panels, otherwise, could result in
fire or electric shock due to accumulation of dust,
sediments, water, moisture, etc.
Only use authorized YMGI parts in the
installation, maintenance, service, and repair of
YMGI units.
The use of non-authorized or
defective parts will void the warranty and could
cause injury or death or property damage due to
water leakage, falling units, fire, electric shock, etc.
Pay extreme caution to interconnecting
refrigerant copper tubing, when installing or
relocating the unit.
Make sure that no other
substance than the specified refrigerant enters the
refrigeration circuit. Any presence of foreign
substances such as air or water or moisture can
cause an abnormal pressure rise or overheat, which
will result in an inefficient unit performance or unit
malfunctions, and will shorten unit lifetime.
Pay extreme caution to interconnecting
refrigerant copper tubing, when installing or
relocating the unit.
Tape two ends of the copper
tubing, tape the wires for the corresponding indoor
unit to the copper tubing, and mark well with either A,
B, C or D to identify each copper tubing/wiring
bundle.
Not to cross wiring or tubing among
indoor units of the multiple zone systems.
The
electrical wiring and copper tubing from each zone
of indoor unit shall be connected to the
corresponding wiring and copper tubing connections
of the corresponding outdoor section (at outdoor
condensing unit). Failure to do so will cause unit
malfunctions, or damages to the compressors and
other parts in the unit and even property or personal
injuries.
DO NOT
install the indoor unit close to cooking
surfaces or ventilation systems. Poor placement
could inhibit peak performance.
DO NOT
blow cold air directly towards people for
extended periods. It may get you a bad cold.
DO NOT
use chemical solvents, flammable
insecticides, or abrasive materials. Clean the unit
only with a soft dry cloth or rag.
DO NOT
continue to operate the unit if there is any
abnormal odor, burning, scorching, or smoke. Stop
and disconnect the unit immediately.
DO NOT
use the system for anything other than what
it was designed for or any non-HVAC purposes. Do
not store near food, paint, or other chemicals.
DO NOT
operate the unit for prolonged periods
without refreshing ambient air. Opening a door or
window periodically will suffice.
DO NOT
draw on the power cord or refrigeration
lines. Install them in secured positions. Plastic
cover of line set is recommended.
DO NOT
blow the cold air directly towards people
for prolonged period. Otherwise, people may get
cold.
DO NOT
use smaller than enough wires. Do not
put several circuits to one breaker. Don't use
smaller than enough circuit breakers. Otherwise
power failure or fire may be caused.
DO NOT
wire or open unit while unit is running.
Sparks or fire may occur. It may cause a shock to
people.
Ground connection
Forbidden
Disconnect the plug
Imperative
IMPORTANT NOTES
P3 OF 24
Subject to Continuous Engineering Improvement without Prior Notice.
P4 OF 24
Subject to Continuous Engineering Improvement without Prior Notice.