Recommended Temperature Ranges-Indoor Side

Mode

Cooling

Heating

Dry Bulb

o

o

61 to 105 F (16 to 40.5 C)

o

o

17 to 86 F (-8 to 30 C)

Wet Bulb

NA

o

o

17-42 F (-8 to 5 F)

Mode

Cooling

Heating

Dry Bulb

Wet Bulb

NA

o

o

17-35 F (-8 to 2 C)

Recommended Temperature Ranges-Outdoor Side

o

o

o

45 F to 115 F (7 to 46.1 C)

o

o

o

17 F to 75 F (-8 to 23.8 C)

OPERATING TEMPERATURE RANGES

NOTES: Since ductless system is not designed to incorporate or use with ducted return or discharge tunnels, 
one single-zone unit SHALL NOT be used to take care of the cooling or heating load of more than one-story 
room. Several single-zone ductless systems or multiple-zone ductless systems shall be used in this regard.

Mode

Cooling

Heating

Dry Bulb-Low

o

64 F 

Wet Bulb-High

o

64 F

o

86 F

o

86 F

Temperature Ranges of Remote/Line Controller

SAFETY-ATTENTIONS

Clean the unit with a soft cloth or dry rag. Do not 
use chemical solvents, flammable insecticide, sprays 
or the likely products to clean the unit. Otherwise, 
damage to the unit may be incurred.

Intall the unit in accordance with all the safety codes
applied. The unit cannot be installed in a wash-
house or where flammable gas could ocurr. The unit 
must be electrically protected by qualified circuit 
breakers.

Do NOT install the indoor unit close to cooking or
ventilation. Otherwise, unit efficiency will be
affected seriously.

Do NOT install the unit in places at risk of farmable
gas leakage. If electric spark is incurred in the unit
accidentally, it could cause a fire or an explosion.

Stop and disconnect the unit immediately after finding
the unit at anomaly oder (burning, scorching

)

Do NOT use the system for other non-HVAC purpose.
Do not store it along with food or painting or other
chemicals.

Close doors and windows. If you use the unit for a
prolonged period and the ambient air turns to be
unpleasant, open a door or a window for a moment
to refresh the atmosphere.

Do NOT use the unit in cool/dry during a prolonged
period at high moisture (higher than 80%).
Condensation could be formed on the indoor unit
casing if a door or window is open or the indoor
humidity is high.

P8 OF 24

Subject to Continuous Engineering Improvement without Prior Notice.

P7 OF 24

Subject to Continuous Engineering Improvement without Prior Notice.

Operate the unit in the temperature ranges shown below. It is not recommended 

to operate the unit out of these ranges, otherwise warranty will be voided.

Important Notes: 

1). Working temperature ranges listed above are guaranteed for units to work properly, though these temperature 
     ranges are conservative.
2). Units may still work well out of the guaranteed working temperature ranges, as long as they are installed 
     properly and are still in good conditions within design envelop.
3). Units are designed for mild low temperature AC cooling applications. Units come with low temperature control 
     to protect againt too low pressure when running for AC cooling in weather colder than 45F and warmer than 
     35F. In this temperature ranges, units may not need to add refrigerant and/or jumper at low pressure switch. If 
     units are to be used for cooling only below 35F, then better to check and add refrigerant and jumper at low 
     pressure switch. Situation varies upon indoor load and indoor unit installation conditions such as TEX type, 
     elvation vs outdoor unit, copper line set size and length, refrigerant level and leakage level.
4.) Units may still work HP heating well way below 17F, though exact temperatures are not listed. Units will defrost 
     during HP heating model in cold weather. Suction (bigger) pipe should be hot and the discharge (smaller) pipe 
     should be warm at outdoor unit during HP heating mode, if everything is right. 
5.) Optional component Wind Baffle installed at fan discharge side on the cabinet is designed to keep from cold air 
     blowing into propeller fan blade against airflow, and so help unit work better in both AC cooling and HP heating 
     mode in colder weather ragnes.

Содержание MINI SPLIT TYPE

Страница 1: ...manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional practices for regular cooling a...

Страница 2: ...echnician Customers must NOT Install This Unit by Themselves or Hire Non Licensed Persons to Do the Job We Decline Any Consequences Including Damage to Unit People Properties and Others Resulted from...

Страница 3: ...ical power is disconnected from the unit by making a notice or put a sign at the power switch panel to keep other people from setting the power back during installation Connect all wiring securely Any...

Страница 4: ...o the Undersized or Oversized Unit Selection Improper Design Incorrect Unit Anticipation and the sort IMPORTANT NOTES AGAIN YMGI IS NOT AND SHALL NOT BE RESPONSIBLE FOR Under performance or damage to...

Страница 5: ...moment to refresh the atmosphere Do NOT use the unit in cool dry during a prolonged period at high moisture higher than 80 Condensation could be formed on the indoor unit casing if a door or window is...

Страница 6: ...cating Lamp Signal Receiving Window Emergency Switch Horizontal Louver Power Plug Vertical Louver Air Outlet Air Filter Remote Controller Air Inlet Connecting Pipe and Cable Drainage Hose Air Outlet O...

Страница 7: ...ovement without Prior Notice COMPONENTS MULTI ZONE SAMPLE DUAL ZONE OVER 500mm 20 Outdoor unit OVER 50mm 2 OVER 100mm 4 OVER 2000mm 80 Indoor unit A OVER 100mm 4 Indoor unit B COMPONENTS MULTI ZONE SA...

Страница 8: ...Set temperature Status indicating bar 2 bar indicator POWER ON Cooling mode Timer mode Fast cooling Auxiliary electrical heating Status indicating bar 4 bar indicator Room temperature reachs to setti...

Страница 9: ...the batteries if you don t use the remote line controller for a long period A Power BATTERY ON OFF Once two AAA batteries are loaded into the remote controller battery compartment in the right polari...

Страница 10: ...ge operation mode as the room temperature changes If unit restarts after last operation stops for two hours it will start in the same mode as set before operation was stopped Press SWING button to cha...

Страница 11: ...T MODE Pointing remote line controller to the unit press MODE button until HEAT is shown In this mode you can press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJUSTMENT...

Страница 12: ...the installer or distributor Unit does not operate at all Remote controller does not display Cooling and heating is not satisfied after running for a long time Blower doesn t run while outdoor unit i...

Страница 13: ...el due to temperature changes at unit startup or shutdown During cooling condensate from pipes or coils accumulated During heating condensate at heat exchanger coil drips During heating at defrosting...

Страница 14: ...AL TECHNICAL QUESTIONS OR SUPPORT 1 The original installer otherwise 2 The current service contractor otherwise 3 The nearest distributor otherwise 4 YMGI Technical Support Tel 866 833 3138 703 Email...

Страница 15: ...r phenomenon you have seen as a unit history No Date Service Maintenance Conducted Person Phone USER NOTES Put down whatever questions you have or phenomenon you have seen as a unit history No Date Qu...

Страница 16: ......

Отзывы: