INITIALIZE THE PROGRAMMING CODE(123456)AND the Card SETTING MANAGEMENT
MODIFY THE CORRESPONDING PERSONAL ACCESS PASSWORD OF CARD
www.yli.cn
We create security
Step 1: Power off ,the RST(SI) wire jumper hat connect to 2/3 interface ,re-up electricity ,
3 long buzz then the Green Light fast flash,the programming code restore to Factory default
Step 2:(If No need to manage Cards,This step can be omitted):Continual to read two blank
Cards(the first one is Added Card,the second one is deleted card),Red light flash,
continuous short buzz.
Step 3:Power off,wire jumper reconnect 1/2,re-up electricity,initialize programming code and
managed card Adding finished
THE USE OF MANAGED CARD
Add User Card : In the standby status,read added Card,then read the user Card want to add at the
end ,read added Card to log out .
Delete User Card: In the standby status,read deleted Card,then read the user card want to
delete,at the end read deleted Card to log out .
Delete all Users:In the standby status,read deleted Card,then read the added card,at the end to
read deleted Card to log out .This operation will delete all users,include personal password
user(not include public password)
USER NO. INTRODUCTIONS
The machine default user ID is contained by 4 digits(for example,0001),add a user each time ,the
user number will add 1 automatic,when remove a single user,this number will be emptied,will not
influence the serial number of new added user(the new added user number will be the last added
user 1),after execute the delete all user command(the programming command 40 or use
Managed Card),the user number will re-start from 0001.Public access password doesn
’
t occupy
the User Serial Number.
Set the open mode as
“
Card+ Password
”
,user read card then input password and press
”
#
”
,open
successfully within 5 sec,long press
”
#
”
until the green light fast flash,meanwhile,input new
password # repeat new password #,1 long buzz,the corresponding personal Access password of
this card is modified successfully.