INSTALLING WIRING DIAGRAM
ACCESS CONTROL FUNCTION SE
T
T
ING
Jp1
Jp2
www.yli.cn
We create security
SILKPRINT
COLOR
FUNCTION
12V
Red
DC 12V Input
GND
Black
Power
PUSH
Blue
Low-leveloutput
OPEN
Yellow
DoorRelease
BELL
Gray
BELL
No.
1
2
3
4
5
6
BELL
White
NO
SILKPRINT COLOR
FUNCTION
NOTE
1
12V
Red
DC 12V Output
Somemodels
withoutthis
interface
2
GND
Black
Power
3
DATA0
Green
WG dataline0
4
DATA1
White
WG dataline1
5
NC
Brown
RelayNC Output
6
COM
Blue
RelayCom output
7
NO
Purple
RelayNO Output
PUSH
GND
12V
NC
NO
GND
(Access control power supply)
POWER
Door Release
BELL
Wg26 OUT/IN(this interface
only apply to some models)
Connect with Automatic
Door and Barrier
NC
COM
NO
Lock
Lock
+
+
12V
GND
DO
D1
12V
GND
PUSH OPEN
BELL
BELL
JP 1
JP 2
EXIT
DOOR
Programming Operating Instruction:(The programming Code Factory Defaults:123456)
NAME
ContinualKey-Press(ReadCard)Operating
NOTE
AddUser
#programmingPassword#1ReadCard#
Add(Modify)Public
Accesspassword
#programmingPassword#21New
Password#
DeleteAll User
DeleteUser(ReadCard)
#ProgrammingPassword#400000
#ProgrammingPassword#410000
This operation will delete
all users,but will not delete
Public Access Password
Continual Read Cardcan
delete multiple Cards at
one-time
Modify programming
Password
#programming Password#0 New
programming Password #Repeat the New
programming Password#
LOST PASSWORD:according
to the initial programming
operation
Continual Read Card can
add multiple Cards at
one-time
Only can set one set of
Public Access password:use
password to
access,input”password”,
then press #
Common
operation