manualshive.com logo in svg
background image

Yingli Solar G/G Modules, Installation and User Manual 

page 1

This manual applies to G/G modules (“G/G modules”, 
also commonly known as Double Glass Modules. 
Hereinafter referred to as PV modules) manufactured 
by Yingli Green Energy Holding Co. Ltd. (“Yingli Solar”), 
and is explicitly written for qualified professionals 
(“Installer” or “Installers”), including without limitation 
licensed electricians and RAL Certified PV Installers.

I N T R O D U C T I O N

Thank you for choosing Yingli Solar as your PV module provider. We appreciate 
your business! This manual contains important information pertaining to the 
electrical and mechanical installation and maintenance of PV modules, and 
contains safety information that you must read carefully and be familiar with 
before handling, installing, and/or maintaining Yingli Solar PV modules.

Yingli Solar does not assume responsibility and expressly disclaims liability for 
losses, damages, or expenses arising out of, or in any way connected with this 
Installation and User Manual. Yingli Solar assumes no responsibility for any 
infringement of patents or other rights of third parties, which may result from 
using Yingli Solar PV modules. No license is granted expressly or by implication 
or under any patent or patent rights. The information in this manual is believed 
to be reliable, but does not constitute an expressed or implied warranty. Yingli

 

Solar reserves the right to make changes to its PV modules and other products, 
their specifications or this manual  without prior notice.

Yingli Solar and its subsidiaries are not liable for any damages caused by  
inappropriate installation, use or maintenance of Yingli Solar PV modules, 
including without limitation damages, losses and expenses caused by non-
observance of the instructions of this manual or caused by or in connection with 
products of other manufacturers.

Yingli Solar PV modules are designed to meet the requirements for the standards 
IEC 61215 and IEC 61730, application class A. Modules rated for use in this 
application class may be used in systems operating at greater than 50 V DC 
or 240 W, where general contact access is anticipated. Modules qualified for 
safety through IEC 61730-1 and IEC 61730-2 and within this application class are 
considered to meet the requirements for safety class II. In the course of the PV 
module certification process, the compliance of this manual with the certification 
requirements has been verified by an independent certification laboratory. 

This Installation and User Manual is available in different languages. In cases of 
discrepancy between versions, the English language version shall control.

Failure to comply with the requirements listed in this manual will invalidate the 
Limited Warranty for PV modules as provided by Yingli Solar at the time of sale 
to the direct customer. Additional recommendations are provided to enhance 
safety practices and performance results. Please provide a copy of this manual 
to the PV system owner for their reference, and inform them of all relevant 
aspects of safety, operation and maintenance.

S A F E T Y

General 

You must understand and follow all applicable local, state and federal 
regulations and standards for building construction, electrical design, fire and 
safety, and must check with local authorities to determine applicable permitting 
requirements before attempting to install or maintain PV modules.

Rooftop PV systems should only be installed on houses that have been formally 
analyzed for structural integrity, and confirmed to be capable of handling the 
additional load of PV system components, including  PV modules, by a certified 
building specialist or engineer.

 

For your safety, do not attempt to work on a rooftop until safety precautions 

have been identified and taken, including without limitation 
fall protection measures, ladders or stairways, and personal 
protective equipment.

For your safety, do not install or handle PVmodules under 

adverse conditions, including without limitation strong or gusty winds, and wet 
or frosted roof surfaces. 

PV modules are photovoltaic products made of tempered glass, encapsulant, 
ribbon, cells and junction boxes. Figure 1 is an illustration of the PV module 
components.

  

 Figure 1: Module components and cross-section of the laminated assembly

Electrical

PV modules can produce current and voltage when exposed to light of any 

intensity. Electrical current increases with higher light 
intensity. DC voltage of 30 Volts or higher is potentially lethal. 
Contacting live circuitry of a PV system operating under light 
can result in lethal electric shock.

De-energize PV modules by removing them entirely from light 

or by

 

covering their front and rear surfaces with an opaque material. Regard the 

safety regulations for live electrical equipment when working with modules that 
are exposed to any light. Use insulated tools and do not wear metallic

 

jewelry 

while working with PV modules.

In order to avoid arcing and electrical shock, do not disconnect electrical 
connections under load. Faulty connections can also result in arcing and 
electrical shock. Keep connectors dry and clean, and ensure that they are in 
proper working condition. Never insert metallic objects into the connectors, or 

Connector

Cable

Junction box

Cell

YINGLISOLAR.COM

YINGLI SOLAR G/G MODULES

Installation and User Manual

Revision date July

 15th,

 2018  |  Applicable for IEC certified products  |  The second edition

File name: Corporate Logo with Tagline / Vertical.ai

Содержание YGE G/G 60CL/F Series

Страница 1: ...trol Failure to comply with the requirements listed in this manual will invalidate the Limited Warranty for PV modules as provided by Yingli Solar at the time of sale to the direct customer Additional...

Страница 2: ...e short side of the box including the corresponding part of the upper lid and the bottom lid see Figure 4 Pay attention to not damage the modules during the cutting process Thirdly cut the two inner s...

Страница 3: ...party electronic devices connected to PV modules may lead to mismatching and must be installed according to the manufacturer s specified instructions Figure 6 Electrical diagrams of series and parall...

Страница 4: ...or optimal performance Yingli Solar recommends that the negative pole of the PV array be connected to ground Equipment Grounding The frame of the PV module as well as any exposed non current carrying...

Страница 5: ...in the mechanical mounting instructions of this installation manual The installation shall follow the instructions below If the installation method is different from this manual please contact Yingli...

Страница 6: ...taller or other qualified person The purpose of the PV system inspection is to ensure that all system components are functioning properly At a minimum this inspection should confirm the following All...

Страница 7: ...e glass surface to enhance power output and reduce dirt and dust buildup In order to avoid module damage do not clean PV modules with a power washer or pressure washer Do not use steam or corrosive ch...

Страница 8: ...8 9 18 1500 15 YL270PG2530L F 1 270 30 7 8 80 37 9 9 27 1500 15 YL275PG2530L F 1 275 31 0 8 90 37 9 9 35 1500 15 YL280PG2530L F 1 280 31 2 8 98 38 0 9 43 1500 15 YL285PG2530L F 1 285 31 4 9 08 38 1 9...

Страница 9: ...coefficient C 0 05 0 32 0 42 YLM G G 72CL F YL330DG2536L F 2 330 37 1 8 90 45 2 9 46 1500 15 YL335DG2536L F 2 335 37 4 8 96 45 4 9 51 1500 15 YL340DG2536L F 2 340 37 7 9 02 45 6 9 56 1500 15 YL345DG25...

Страница 10: ...n and User Manual page 10 CLAMP INSTALLATION DRAWINGS OF PV MODULES UNITS mm YGE G G 60CL YGE G G 72CL YLM G G 60CL YLM G G 72CL 992 1975 360 635 635 350 200 992 1975 360 635 635 350 200 360 953 345 9...

Страница 11: ...3 8 Grounding holes 8 6 1981 365 633 633 350 100 998 1981 32 1981 998 Drainage holes 8 3 8 Grounding holes 8 6 365 633 633 350 100 998 1664 32 1664 998 365 949 350 Drainage holes 8 3 8 100 Grounding h...

Отзывы: