background image

Yingli Solar PV Modules, Installation and User Manual 

page 9

PANDA 60 Cell 

Series 

YL270C-30b

270

30.5

8.85

38.6

9.43

1000

15

YL265C-30b

265

30.1

8.79

38.3

9.37

1000

15

YL260C-30b

260

29.7

8.74

38.1

9.35

1000

15

YL255C-30b

255

29.4

8.68

37.8

9.29

1000

15

YL250C-30b

250

29.1

8.6

37.5

9.14

1000

15

YL245C-30b

245

30.4

8.07

38.1

8.59

1000

15

YL240C-30b

240

30.3

7.93

38.0

8.47

1000

15

YL235C-30b

235

29.9

7.87

37.6

8.41

1000

15

YL230C-30b

230

29.6

7.76

37.0

8.40

1000

15

YL225C-30b

225

29.4

7.66

36.4

8.39

1000

15

PANDA 48 Cell 

Series 

YL215C-24b

215

24.4 

8.81 

30.9 

9.41 

1000

15

YL210C-24b

210

24.2 

8.69 

30.7 

9.34 

1000

15

YL205C-24b

205

23.9 

8.57 

30.5 

9.27 

1000

15

YL200C-24b

200

23.7 

8.44 

30.2 

9.14 

1000

15

YL195C-24b

195

23.4 

8.32 

30.0 

9.00 

1000

15

YL190C-24b

190

23.9

7.95

30.1

8.50

1000

15

YL185C-24b

185

23.7

7.81

29.6

8.44

1000

15

YL180C-24b

180

23.5

7.66

29.1

8.41

1000

15

Содержание PANDA 48 Cell Series

Страница 1: ...ngli Solar at the time of sale to the direct customer Additional recommendations are provided to enhance safety practices and performance results Please provide a copy of this manual to the PV system...

Страница 2: ...PV module surfaces and do not apply paint or adhesive to any of the surfaces including the frame For your safety do not disassemble or modify Yingli Solar PV modules in any way Doing so may degrade pe...

Страница 3: ...m2 AM 1 5 and 25 C cell temperature As required by the US National Electric Code NEC the short circuit current Isc should be multiplied by a factor of 1 25 and the open circuit voltage Voc should be m...

Страница 4: ...rts of fixed equipment that are able to become energized by the PV system must be connected to the equipment grounding conductor in order to prevent electrical shock Refer to section 250 of the NEC fo...

Страница 5: ...for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated through the...

Страница 6: ...ds that PV systems be periodically inspected by the installer or other qualified person ThepurposeofthePVsysteminspectionistoensurethatallsystemcomponents are functioning properly At a minimum this in...

Страница 7: ...The fifth 2014 Installation Manual_UL_ EN_201404_v02 1 August 6 2014 The sixth 2014 Installation Manual_UL_ EN_201408_v02 2 March 18 2015 The seventh 2015 Installation Manual_UL_ EN_201503_v02 3 June...

Страница 8: ...t of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power output...

Страница 9: ...YL240C 30b 240 30 3 7 93 38 0 8 47 1000 15 YL235C 30b 235 29 9 7 87 37 6 8 41 1000 15 YL230C 30b 230 29 6 7 76 37 0 8 40 1000 15 YL225C 30b 225 29 4 7 66 36 4 8 39 1000 15 PANDA 48 Cell Series YL215C...

Страница 10: ...0 38 07 967 43 31 1100 3 94 100 2 17 55 3 94 100 3 94 100 A A A A 38 98 990 37 24 946 1 97 50 22 72 577 16 02 408 77 56 1970 22 72 577 77 56 1970 47 24 1200 3 94 100 Grounding holes 6 0 236 6 Mounting...

Страница 11: ...AR AND SIDE VIEW DIMENSIONS OF MODULE SERIES UNITS INCH mm PANDA 48 Cell SERIES PANDA 60 Cell SERIES Legend Legend Grounding holes Mounting holes Drainage holes Mounting tolerance PANDA 48 Cell PANDA...

Отзывы: