Cause: Deformation may occur in the cables that the device communicates with the control unit. There
may be a failure in the YHC or control panel.
Device Response: When the device detects this error, it will go into stop mode by cooling if it is
working.
Troubleshooting:
* Check the cables and sockets where the device communicates with the control unit.
* If there are no problems, replace the control unit and perform the necessary repair if there is
deformation in the cables or sockets.
* The device cannot be reset from the control panel !! Power down the system and give it again.
E 17 : Control Unit Communication Failure
Cause: While the device is operating, an element that prevents the operation of the fan may have
entered the device. The magnetic sensor may have malfunctioned. If the device is intervened, the
distance between the outside air impeller and the holder T plastic may be incorrectly set. There may
be elements that impede the operation of the propeller that delivers air to the combustion chamber.
For similar reasons, since the fan motor tries to maintain its operating speed, the current it uses may
increase and the device may see fan motor high current failure.
Device Response: When the device detects this error, it will switch to stop mode if it is working.
Troubleshooting:
* Make sure that no external elements get inside the device.
* Ensure that the distance between the outside air impeller and the holder T plastic is within the
standards.
* Make sure that the YHC is in the correct position.
* Be sure to reset the device from the button or disconnect the system from the power supply and
connect again.
E 18 : Fan Operating Failure
Cause: The fuel tank may be out of fuel or the fuel hose may be clogged. The combustion air intake or
exhaust outlet may be clogged or deformed. The exhaust line or indoor air intake line may be improperly
installed, with with inverse airflow into the device.
Device Response: If the device is working when it detects this error, it will switch to stop mode by
cooling.
Troubleshooting:
* Make sure the exhaust outlet and combustion air intake hoses are not blocked or improperly installed.
* Make sure there is fuel in the fuel tank.
* Make sure the fuel hose is not blocked.
* Try to start the device after refueling the fuel tank, if the device does not work in 2 attempts, it will give
the same error again, reset it from the button or disconnect the system from the power supply and
connect again.
E 19 : Combustion Stop Failure