Figure 3-1. First System 

Analyzer Display

1 Date and Time. (See Chapter 5 to set).
2 Pressure units. While using any of the digital 

manifold or vacuum gauge display screens, 

press the UP/LEFT key to activate a pop-up 

screen where options can be changed using 

the UP/LEFT and DOWN/RIGHT keys. 

Press the MENU key to save the selections 

and exit the pop-up screen.

3 Refrigerant type. While using any of the 

digital manifold or vacuum gauge display 

screens, press the UP/LEFT key to activate 

a pop-up screen where options can be 

changed using the UP/LEFT and DOWN/

RIGHT keys. Press the MENU key to save 

the selections and exit the pop-up screen.

4 Battery strength. (See Chapter 2 for battery 

considerations).

5 The minimum and maximum pressures 

encountered since the memory was last 

cleared. (“Clear” key - typical for high and 

low sides).

6 Set: The pressure represented by the center 

horizontal line on both charts.

Crs: (Cursor) The charted pressure marked 

by the vertical line on both charts.

7 Left Side: Vapor Saturate. The vapor satura-

tion temperature for the selected refrigerant. 

(Also known as dew point)

Right Side: Liquid Saturate. The liquid satu-

ration temperature for the selected refriger-

ant. (Also known as bubble point)

8 Temp-1 (T1): The temperature indicated by 

the T1 thermocouple. (For proper superheat 

measurement, the T1 probe should be mea-

suring the suction line temperature.)

Temp-2 (T2): The temperature indicated by 

the T2 thermocouple. (For proper subcool-

ing measurement, the T2 probe should be 

measuring the liquid line temperature.)

While using any of the digital manifold or 

vacuum gauge display screens, press the 

UP/LEFT key to activate a pop-up screen 

where options can be changed using the 

UP/LEFT and DOWN/RIGHT keys. Press 

the MENU key to save the selections and 

exit the pop-up screen.

9

Superheat: The calculated superheat for 

the selected refrigerant.

Subcool: The calculated subcooling for 

the selected refrigerant.

NOTE: These calculations are based     

on the measured pressures and          

temperatures.

10 Charted pressure
11 Time indication (cursor)
12 Seconds per samples (sample interval). 

Use the “Chart Time” key to toggle this 

value through the available settings.

A small number will show rapid pressure 

changes by displaying a short period of 

time (‘zoom in’). A large number will show 

only slower pressure changes by display-

ing a larger period of time (‘zoom out’).

13 Pressure scale range. Use the “Chart 

Pres.” Key to toggle pressure resolution 

to fit analog pressure data within the 

display, enhancing a user’s ability to see 

significant events. A small range will show 

small pressure changes (‘zoom in’). A 

larger range will show only larger pres-

sure changes (‘zoom out’).

14 Left Side: Suction pressure (‘Low Side’)

Right Side: Discharge pressure

(‘High Side’)

8

Figure 3-2. 2nd System Analyzer Display

Содержание 40812

Страница 1: ...ached to the instrument YELLOW JACKET Refrigeration System Analyzer Users Manual UPC 40812 40813 and 40815 Versions 1 06 and higher 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1...

Страница 2: ...ions 15 Safety 15 Chapter Title Pg Features and Specifications 15 Instrumentation Specifications 16 Warranty Policy 16 Table of Contents List of Tables Table Title Pg 1 1 Safety Information 3 1 2 Symb...

Страница 3: ...ced only by Ritchie Engineering Co or authorized service centers Do not use the instrument if it operates ab normally Protection may be impaired When in doubt have the instrument serviced Refer to war...

Страница 4: ...page by page scrolling mode during data log playback Battery Battery connector orientation Chapter 2 Getting Acquainted Introduction This instrument will clearly and accurately report critical inform...

Страница 5: ...is detected Once the data is stored unit will turn off Maximizing Battery Life Battery life decays fastest when the DIGITAL MANIFOLD display is selected the vacuum sen sor is attached and the backlig...

Страница 6: ...Chart Display This display shows the P T Pressure Tempera ture chart for the refrigerant that is selected in the Set Up display Use the or keys to scroll through the chart Press the Menu key to exit...

Страница 7: ...Transducer internal High Side Pressure Transducer internal Temperature Probes The system analyzer will display readings from any K type thermocouple probe with a miniature style connector see picture...

Страница 8: ...erheat measurement the T1 probe should be mea suring the suction line temperature Temp 2 T2 The temperature indicated by the T2 thermocouple For proper subcool ing measurement the T2 probe should be m...

Страница 9: ...High Side 3 When data recording is activated this indicator will gradually change from red to blue indicating the size of one page of data During playback it will help the user to decide whether to mo...

Страница 10: ...for signs of oil before connecting the 69086 vacuum gauge sensor Keep the sensor vertical when possible Connect the gauge directly to the system away from the pump Isolate the pump from the system an...

Страница 11: ...and reporting at a later time Figure 4 3 Data Log Files Erase File Use the arrow keys to highlight the data file to be erased Press clear to erase Erase All Files Press clear to erase all data files...

Страница 12: ...ry default is MM DD YY Time and Date These settings are modified in a slightly different manner Selecting this setting for modification will open a pop up window Each component of the time and date va...

Страница 13: ...as dish soap If the unit encounters enough exposure to liquid chemicals that the chemical wicks between the in strument boot and the case immediately remove the boot and clean the case as described ab...

Страница 14: ...tem Analyzer Instrument Boot 40823 System Analyzer Battery Door 40824 System Analyzer Bumper Plugs Sensor Boots 40827 USB cable 69101 Vacuum Sensor Cord Assembly 69217 K Type Clamp Probe 10 ft Softwar...

Страница 15: ...ls back to past readings Refrigerant Database 98 NIST refrigerant profiles included upgradeable Data Logging Adjustable time intervals from 0 1 to 10 seconds minimum of 24 hours at 1 0 second interval...

Страница 16: ...Company Inc is guaranteed to be free from material and workmanship defects for a period of two years All other YELLOW JACKET products included in this package are guaranteed to be free from material a...

Отзывы: