yellow jacket 40812 Скачать руководство пользователя страница 16

16

Instrumentation         

Specifications

Pressure 

Sensing

Resolution

Low side: 0.1 psi, 0.01bar, 

1kPa, 0.01MPa, 0.01kg/cm²
High side: 0.1 psi, 0.01bar, 

1kPa, 0.01MPa, 0.01kg/cm²

Pressure 

Sensing  

Accuracy

0.5% of full scale at 25ºC 
1% of full scale 55ºF to 130ºF
2% of full scale -40ºC to 120ºC

Working 

Pressure

Low side: 0 – 350 psia 
High side: 0 – 700 psia

Proof   

Pressure

Tolerable pressure without 

internal damage
Low side: 1000 psi
High side: 1000 psi

Burst    

Pressure

Tolerable pressure without loss 

of seal
Low side: 1500 psi
High side: 1500 psi

Temperature 

Sensor Range 

(Instrument)

-100°F to 600°F

Temperature 

Display

Resolution

0.1°F or °C

Temperature 

Accuracy

(Instrument)

±1.8°F (±1°C)

Vacuum 

Display 

Resolution

Shows two most significant 

digits in microns (25xxx-

10xxx, 99xx-10xx, 99x-10x, 99-

10); other units - direct conver-

sions from the micron value

Vacuum 

Accuracy

20% of reading

Warranty Policy

The YELLOW JACKET® Refrigeration System 

Analyzer from Ritchie Engineering Company, 

Inc. is guaranteed to be free from material and 

workmanship defects for a period of two years.   

All other YELLOW JACKET® products included  

in this package are guaranteed to be free from 

material and workmanship defects for a period of 

one year. These guarantees do not cover prod-

ucts that have been altered, abused, misused or 

improperly maintained.  

Not all catalogued products are stocked and eli-

gible for return. Please check with your YELLOW 

JACKET representative or the factory for more 

information. 

All returns must have an RGA number and proof 

of purchase/copy of invoice. Please obtain an 

RGA number from Ritchie Engineering Customer 

Service by calling 800-769-8370. 

All returns must be pre-paid.

©2009-2014 Ritchie Engineering Co., Inc.

Printed in USA

P/N 500935_D

Features, cont.

Housing

Highly weather resistant; glass-

fiber reinforced, engineering 

grade thermoplastic

Hook

Integral hook swivels 360° and 

stows when not used

Leaks

Due to high accuracy and reso-

lution of the pressure transduc-

ers, leaks in equipment can be 

quickly sensed

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Содержание 40812

Страница 1: ...ached to the instrument YELLOW JACKET Refrigeration System Analyzer Users Manual UPC 40812 40813 and 40815 Versions 1 06 and higher 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1...

Страница 2: ...ions 15 Safety 15 Chapter Title Pg Features and Specifications 15 Instrumentation Specifications 16 Warranty Policy 16 Table of Contents List of Tables Table Title Pg 1 1 Safety Information 3 1 2 Symb...

Страница 3: ...ced only by Ritchie Engineering Co or authorized service centers Do not use the instrument if it operates ab normally Protection may be impaired When in doubt have the instrument serviced Refer to war...

Страница 4: ...page by page scrolling mode during data log playback Battery Battery connector orientation Chapter 2 Getting Acquainted Introduction This instrument will clearly and accurately report critical inform...

Страница 5: ...is detected Once the data is stored unit will turn off Maximizing Battery Life Battery life decays fastest when the DIGITAL MANIFOLD display is selected the vacuum sen sor is attached and the backlig...

Страница 6: ...Chart Display This display shows the P T Pressure Tempera ture chart for the refrigerant that is selected in the Set Up display Use the or keys to scroll through the chart Press the Menu key to exit...

Страница 7: ...Transducer internal High Side Pressure Transducer internal Temperature Probes The system analyzer will display readings from any K type thermocouple probe with a miniature style connector see picture...

Страница 8: ...erheat measurement the T1 probe should be mea suring the suction line temperature Temp 2 T2 The temperature indicated by the T2 thermocouple For proper subcool ing measurement the T2 probe should be m...

Страница 9: ...High Side 3 When data recording is activated this indicator will gradually change from red to blue indicating the size of one page of data During playback it will help the user to decide whether to mo...

Страница 10: ...for signs of oil before connecting the 69086 vacuum gauge sensor Keep the sensor vertical when possible Connect the gauge directly to the system away from the pump Isolate the pump from the system an...

Страница 11: ...and reporting at a later time Figure 4 3 Data Log Files Erase File Use the arrow keys to highlight the data file to be erased Press clear to erase Erase All Files Press clear to erase all data files...

Страница 12: ...ry default is MM DD YY Time and Date These settings are modified in a slightly different manner Selecting this setting for modification will open a pop up window Each component of the time and date va...

Страница 13: ...as dish soap If the unit encounters enough exposure to liquid chemicals that the chemical wicks between the in strument boot and the case immediately remove the boot and clean the case as described ab...

Страница 14: ...tem Analyzer Instrument Boot 40823 System Analyzer Battery Door 40824 System Analyzer Bumper Plugs Sensor Boots 40827 USB cable 69101 Vacuum Sensor Cord Assembly 69217 K Type Clamp Probe 10 ft Softwar...

Страница 15: ...ls back to past readings Refrigerant Database 98 NIST refrigerant profiles included upgradeable Data Logging Adjustable time intervals from 0 1 to 10 seconds minimum of 24 hours at 1 0 second interval...

Страница 16: ...Company Inc is guaranteed to be free from material and workmanship defects for a period of two years All other YELLOW JACKET products included in this package are guaranteed to be free from material a...

Отзывы: