background image

Mode 3 – Charge Only

 

The Charge Only function is designed to add a      
precise amount of refrigerant when the A/C system is 
low on refrigerant.  This mode is most often used 
when the A/C system is working but does not produce 
sufficiently cold air.   

MODE 3 Operational Steps

1.  Refer to the Pre-Operation Check List.  

NOTE:  If desired, the gauges of the Model 800 
can now be used to aid investigation of an A/C 
system problem.  Ensure the automobile A/C   
system is turned off prior to selecting a mode on 
the Model 800. 

2.  Verify the auto air conditioning system is off. 

3.  Press MODE 3 for Charge Only.   

4.  The LCD will read 

CONNECT HOSES ENTER TO 

CONTINUE

. Press the 

ENTER

 key.  

5.  Connect the high and low side auto service hoses 

to the respective high and low side service ports 
on the automobile A/C system. Open the service 
hose valves. 

6.  When the LCD reads 

“SET CHARGE AMOUNT,” 

set the amount of refrigerant to be charged into 
the A/C system by pressing and holding the      
INCREASE or DECREASE key until the desired 
amount is shown. Release the key and press   
ENTER to set the charge amount on the LCD. 

7.  The LCD should read 

“PUSH START.”

 

8.  Press START key to begin charging operations. 

The 800 Series will start the charge cycle. 

The LCD will display the charging process progress. 
The unit will beep when the desired charge amount 
has been transferred to the A/C system. 

9.  Verify the message on the LCD reads 

“CHRG 

ONLY COMPLETE.” 

Unit will force a hose    

clearing routine (See Full cycle). 

10.  Shut the service valves and disconnect the high 

and low side auto service hoses from the auto. 

11.  Press the RESET key to return to the 

“SELECT 

MODE”

 status. 

Mode 4 – Full Cycle

 

The Full Cycle function of the Model 800 is designed 
to remove and recycle all refrigerant in an A/C system 
by transferring the refrigerant to the storage tank,   
remove moisture in the system by pulling a vacuum, 
and charging the system with a precise amount of       
refrigerant.   

MODE 4 Operational Steps  

1.  Refer to the Pre-Operation Check List. 

NOTE:  If desired, the gauges of the Model 800 
can now be used to aid investigation of an A/C 
system problem.  Ensure the automobile A/C   
system is turned off prior to selecting a mode on 
the Model 800. 

2.  Verify the auto air conditioning system is off. 

3.  Press MODE 4 for Full Cycle.  The LCD will read 

“CONNECT HOSES”

 

4.  Connect the high and low side auto service hoses 

to the respective high and low side service ports 
on the automobile A/C system. Open the service 
hose valves. Press the ENTER key to continue. 

5. 

When the LCD reads

 “SET VACUUM TIME,”

 set 

the vacuum hold time by pressing and holding  
INCREASE or DECREASE until the desired time 

is shown.  Release the button and press ENTER 
to accept the vacuum hold time on the LCD.  

 

NOTE: Vacuum hold time can be bypassed if the 
time is set to zero.

 

6.  When the LCD reads

 “SET VAC HOLD TIME,”

 

set the vacuum time by pressing and holding    
INCREASE or DECREASE until the desired time 
is shown. Release the button and press ENTER to 
accept the vacuum hold time shown on the LCD. 

NOTE: Vacuum hold time can be bypassed if the 
time is set to zero.

 

7.  When the LCD reads 

“SET CHARGE AMOUNT,” 

set the amount of refrigerant to be charged into 
the A/C system by pressing and holding            
INCREASE or DECREASE until the desired 
amount is shown. Release the button and press 
ENTER to accept the charge amount on the LCD. 

8.  The LCD should read 

“PUSH START.” 

 

9.  Press START KEY to begin full cycle operations. 

10.  The unit will begin to recover as outlined for the 

Recovery Only cycle, and then evacuate the A/C 
system and will beep to indicate the end of the 
vacuum time— if Vacuum Hold is used. 

Содержание 39800

Страница 1: ...Automatic Refrigerant Recovery Recycling Recharge System Model 39800 Operation Manual For Automotive Applications YELLOW JACKET...

Страница 2: ...ath Deliberate inhalation of refrigerants is extremely dangerous Death can occur without warning Vapors reduce oxygen available for breathing and are heavier than air Decomposi tion products are hazar...

Страница 3: ...nting when disconnecting from the automobile Only Use the Model 800 Series with the Correct Refrigerants See the specifications for a list of compatible refrigerants Operate the Unit within the Design...

Страница 4: ...uge 3 Low Gauge 4 Auto High Side Hose Red 5 Auto Low Side Hose Blue 6 Tank Liquid Hose Red 7 Tank Vapor Hose Blue 8 Oil Drain Bottle 9 Oil Inject Bottle 10 Tool Tray 11 Main Power Switch 12 Oil Inject...

Страница 5: ...bile A C system This mode is most often used prior to opening an A C system to atmosphere to replace a system component 2 MODE 2 Vacuum is used to vacuum air from a system previously opened to the atm...

Страница 6: ...now be used to aid investigation of an A C system problem Ensure the automobile A C system is turned off prior to selecting a mode on the 800 SERIES 2 Connect the high and low side auto service hoses...

Страница 7: ...until the desired time is shown Release the button and press ENTER to accept the vacuum time shown on the LCD By pass vacuum time by setting time to zero 8 When the LCD reads SET VACUUM HOLD TIME set...

Страница 8: ...ned to remove and recycle all refrigerant in an A C system by transferring the refrigerant to the storage tank remove moisture in the system by pulling a vacuum and charging the system with a precise...

Страница 9: ...Tank Refill In order to use the charging mode you must have at least six 6 pounds of refrigerant in the storage tank Follow this procedure to add refrigerant to the storage tank When adding R 134a to...

Страница 10: ...GEMENT SYSTEM Press INCREASE or DECREASE to cycle through the registers The registers are Register 1 Total number of jobs to date Register 2 Cumulative run time in minutes Register 3 Refrigerant recov...

Страница 11: ...Vacuum Pump Oil Pressing the ENTER key will turn the reminder off un til the next time you start the unit Pressing the RE SET key will reset the reminder until the next sched uled maintenance Check o...

Страница 12: ...not responding call Technical Support Call Technical Support Call Technical Support Call Technical Support Fan not running in any cycle Loose power wire to fan Microprocessor malfunction Fan malfunct...

Страница 13: ...ng Call Technical Services Tank or scale misaligned Reposition tank and scale Time Limit during recovery cycle A C system has a leak Locate and repair leak Valves on service hoses shut Open valves Ser...

Страница 14: ...tory for repair If found defective we will upon compliance with the return instructions either credit replace or repair at our option the defective product provided it is returned within one year of t...

Отзывы: