yellow jacket 39800 Скачать руководство пользователя страница 10

10 

Purging Non-Condensable Gases

 

The Model 800 is designed to automatically purge 
non-condesable gases such as air present in the 
storage tank. When the pressure in the tank exceeds 
a threshold value, the unit will automatically purge the 
excess pressure. The unit will only purge when it is 
first turned on. The current purge status is displayed 
in the upper right corner of the LCD when in Select 
Mode. 

The purge status in the LCD should be either 

“Y”, 

“N”, 

or 

“E.”  

“Y” 

indicates air is present in the tank. 

The unit will purge the next time it is turned off and on.  
An 

“N” 

in the window indicates a purge is not needed.   

An 

“E” 

will display on the LCD if the previous purge 

was insufficient to lower the non-condensable gas 
value below the limit.  The purge time is set to 30 
seconds to minimize refrigerant loss. If the LCD 
continues to display an 

“E” 

after several purge 

cycles, there may be an error in the system.  Check 
the pressure in the tank to determine if the system is 
purging unnecessarily.   

 

If the unit continues to display 

“Y” 

or an 

“E” 

and the 

tank pressure is near the value in the table below, 
contact Ritchie Engineering Customer Service at 
(800)769-8370. 

Mode 7– Refrigerant Management System, cont.

 

The refrigerant management information is stored in 
nine registers.  To access the information, press 
Mode 7, REFRIGERANT MANAGEMENT SYSTEM.  
Press INCREASE or DECREASE to cycle through the 
registers.  The registers are: 

Register 1:

  Total number of jobs to date. 

Register 2:

  Cumulative run time in minutes. 

Register 3:

  Refrigerant recovered during last job. 

Register 4:

  Refrigerant charged in last job. 

Register 5:

  Run time of last job. 

Register 6:

  Total amount of refrigerant recovered to 

date. 

Register 7:

  Total amount of refrigerant charged to 

date. 

Register 8:

  Total of all new refrigerant added to the 

storage tank to date. 

Maintenance Reminders

 

Approximate Pressure (psig)

 

Temp (ºF) 

R-12 

R-134a 

65 

74 

74 

70 

80 

81 

75 

87 

88 

80 

96 

97 

85 

102 

115 

Temp (ºF) 

R-12 

R-134a 

90 

110 

120 

95 

118 

126 

100 

127 

135 

105 

136 

145 

110 

146 

155 

FILTER - “MAINT-FILTER CHG DUE” 

The Model 800 has a unique filter system which     
ensures the refrigerant transferred to the storage   
cylinder is clean and moisture-free. The filters must be 
changed periodically to ensure the system is working 
properly. A maintenance reminder prompts you when 
to change your filters. All refrigerant must be removed 
from the old filters before they are removed. Follow 
the filter change procedures carefully to minimize   
refrigerant loss and ensure only clean, moisture-free 
refrigerant is transferred into the storage cylinder. 

Pressing the ENTER key will turn the reminder off  
until the next time you start the unit. Pressing the   
RESET key will reset the reminder until the next 
scheduled maintenance.  

Filter Change Steps: 

1.  Turn on system power 
2.  Run recovery cycle 
3.  Remove filter drier 
4.  Replace filter drier 

 

Содержание 39800

Страница 1: ...Automatic Refrigerant Recovery Recycling Recharge System Model 39800 Operation Manual For Automotive Applications YELLOW JACKET...

Страница 2: ...ath Deliberate inhalation of refrigerants is extremely dangerous Death can occur without warning Vapors reduce oxygen available for breathing and are heavier than air Decomposi tion products are hazar...

Страница 3: ...nting when disconnecting from the automobile Only Use the Model 800 Series with the Correct Refrigerants See the specifications for a list of compatible refrigerants Operate the Unit within the Design...

Страница 4: ...uge 3 Low Gauge 4 Auto High Side Hose Red 5 Auto Low Side Hose Blue 6 Tank Liquid Hose Red 7 Tank Vapor Hose Blue 8 Oil Drain Bottle 9 Oil Inject Bottle 10 Tool Tray 11 Main Power Switch 12 Oil Inject...

Страница 5: ...bile A C system This mode is most often used prior to opening an A C system to atmosphere to replace a system component 2 MODE 2 Vacuum is used to vacuum air from a system previously opened to the atm...

Страница 6: ...now be used to aid investigation of an A C system problem Ensure the automobile A C system is turned off prior to selecting a mode on the 800 SERIES 2 Connect the high and low side auto service hoses...

Страница 7: ...until the desired time is shown Release the button and press ENTER to accept the vacuum time shown on the LCD By pass vacuum time by setting time to zero 8 When the LCD reads SET VACUUM HOLD TIME set...

Страница 8: ...ned to remove and recycle all refrigerant in an A C system by transferring the refrigerant to the storage tank remove moisture in the system by pulling a vacuum and charging the system with a precise...

Страница 9: ...Tank Refill In order to use the charging mode you must have at least six 6 pounds of refrigerant in the storage tank Follow this procedure to add refrigerant to the storage tank When adding R 134a to...

Страница 10: ...GEMENT SYSTEM Press INCREASE or DECREASE to cycle through the registers The registers are Register 1 Total number of jobs to date Register 2 Cumulative run time in minutes Register 3 Refrigerant recov...

Страница 11: ...Vacuum Pump Oil Pressing the ENTER key will turn the reminder off un til the next time you start the unit Pressing the RE SET key will reset the reminder until the next sched uled maintenance Check o...

Страница 12: ...not responding call Technical Support Call Technical Support Call Technical Support Call Technical Support Fan not running in any cycle Loose power wire to fan Microprocessor malfunction Fan malfunct...

Страница 13: ...ng Call Technical Services Tank or scale misaligned Reposition tank and scale Time Limit during recovery cycle A C system has a leak Locate and repair leak Valves on service hoses shut Open valves Ser...

Страница 14: ...tory for repair If found defective we will upon compliance with the return instructions either credit replace or repair at our option the defective product provided it is returned within one year of t...

Отзывы: