u
d7: Offset Frequency
No.
(Addr.
Hex)
Name
LCD Display
Description
Setting
Page
d7-01
(2B2)
Offset Frequency 1
Offset Freq 1
Added to the frequency reference when the digital input
“Frequency offset 1” (H1-
oo
= 44) is switched on.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
d7-02
(2B3)
Offset Frequency 2
Offset Freq 2
Added to the frequency reference when the digital input
“Frequency offset 2” (H1-
oo
= 45) is switched on.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
d7-03
(2B4)
Offset Frequency 3
Offset Freq 3
Added to the frequency reference when the digital input
“Frequency offset 3” (H1-
oo
= 46) is switched on.
Default: 0.0%
Min.: -100.0
Max.: 100.0
–
B.4 d: References
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
295
B
Parameter List