![YASKAWA VS mini V7 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/yaskawa/vs-mini-v7/vs-mini-v7_user-manual_3066242045.webp)
8 Protective Operations
45
8.2
Alarm Processing
SI-T/V7 Communications Fault Detection
The following tables show the communications faults detected by the SI-T/V7 and the con-
ditions in which they can be detected.
Table 6 Response Data for Consecutive Alarms and/or Warnings
Fault Detection
MECHATROLINK-II Response Data Contents
Previous
Value
Most Recent
Value
Alarm
STATUS
WARNG
ALM
Alarm
Alarm
Most recent alarm code
0
1
Alarm
Warning
Most recent alarm code
1
1
Warning
Alarm
Most recent alarm code
1
1
Warning
Warning
Warning with the smaller warning code
1
0
Table 7 Reception Failures in Each Phase
Communications
Phase
Reception Failure
Transmission cycle
First
Second (Consecutive)
Fault
Phase 1
−
−
−
Phase 2
96
E6
E6
Phase 3
96
E6
E6
Table 8 Alarm Code (MECHATROLINK-II Response ALARM Value)
ALARM
Description
Fault Type
96
MECHATROLINK-II communications fault warning
Communications warning
E5
MECHATROLINK-II WDT fault
Communications alarm
E6
MECHATROLINK-II communications fault
Communications alarm
Table 9 Fault Types
Fault
Description
Communications failure
Transmission LSI detected a data reception failure.
Transmission cycle fault
A timing fault of a synchronous frame in a transmission cycle was
detected.
Watchdog timer fault
A WDT count fault in a synchronous frame was detected.