4
Deployment
4.1 Fast introduction
Limits
Valid range of values
Lower counter limit
-2 147 483 648 (-2
31
)
Upper counter limit
+2 147 483 647 (2
31
-1)
The maximum counter frequency is 400kHz.
At CPU, PROFIBUS and PROFINET the input area is embedded to the corresponding
address area.
IX - Index for access via CANopen
SX - Subindex for access via EtherCAT with Index 6000h + EtherCAT-Slot
More can be found in the according manual of your bus coupler.
Addr.
Name
Bytes
Function
IX
SX
+0
CV_I
4
Counter 0:
Counter value
5400h/s
01h
+4
CV_II
4
Counter 1:
Counter value
5400h/s+1
02h
+8
CSTS_I
2
Counter 0:
Counter status
5402h/s
03h
+10
CSTS_II
2
Counter 1:
Counter status
5402h/s+1
04h
At CPU, PROFIBUS and PROFINET the output area is embedded to the corresponding
address area.
IX - Index for access via CANopen
SX - Subindex for access via EtherCAT with Index 7000h + EtherCAT-Slot
More can be found in the according manual of your bus coupler.
Addr.
Name
Bytes
Function
IX
SX
+0
CCTRL_I
2
Counter 0:
Control word
5602h/s
01h
+2
CCTRL_II
2
Counter 1:
Control word
5602h/s+1
02h
Counter range
Address areas
Input area
Output area
VIPA System SLIO
Deployment
Fast introduction
HB300 | FM | 050-1BB30 | en | 20-40
47